Although the systems considered in this section do not exhibit controlled tautomerism, they show a promising concept for E/Z isomerization switching, where the tautomeric process is believed to play an important role. [Pg.290]


An adjustable glass column of 9mm ID, packed with 5g of Fractosil 200 was connected to a Spectra Physics pump connected to solvent reservoirs with a six way rotary switch. The sample was injected onto the column with a rotary loop sampler. The effluent from the column was collected with an Isco fraction collector set so that 10 ml of eluate was collected for each... [Pg.215]

Suzuki coupling of 9,10-dibromoanthracene and boronic acids produces a separable mixture of the cis and trans isomers of 9,10-diarylanthracene 64 which independently behave as a molecular rotary switch on treatment with 02 via the endoperoxide (Scheme 46)... [Pg.423]

Fig. 8 (a) Chemical and stylized representation of the strategy of redox-mediated molecular brake passing from sulhde to sulfoxide and sulfone (b) an example of oxygen-flipped rotary switch (c) its stylized representation (d) X-ray structure of a bisarylanthracene peroxide (H atoms were omitted for clarity) (e) control of the frequency of molecular motions in rotaxanes of which annulus (macrocycle) contains a photoisomerizable dianthrylethane group (see text for details)... [Pg.271]

Now that you have them all correctly connected, you need to assign each device a unique SCSI ID number. This number can be assigned by jumper (with internal devices) or with a rotary switch (on external devices). You start by assigning your adapter an address. This number can be any number from 0 to 7 on an 8-bit bus, 0 to 15 on a 16-bit bus, and 0 to 31 on a 32-bit bus, as long as no other device is using that ID. [Pg.183]

Manual Rotary Switch of 1 Clean Water Pump SB6 X014... [Pg.356]

Manual Rotary Switch of 2 Clean Water Pump SB7 X015... [Pg.356]

Manual Rotary Switch of Aeration Blower SB8 X022... [Pg.356]

To complete the test, the worker told his co-worker to drop the table. In machine-speak that meant lowering the bottom bowl. A rotary switch on a control panel managed the up-down movement of the table. The coworker stood to the right of the table and turned the switch to lower the bowl. Instead, it went up and crushed the set-up worker s thumbs. [Pg.64]

A second mold-making machine had the same layout, but the molds exited on that conveyor in an opposite direction. The control panel was on the left of the table. The rotary switch on each control panel operated the same and had the same labels. Rotating right meant the table moved down. Rotating left meant the table moved up. [Pg.64]

Resistance Another means to prevent inadvertent operation of a control is to introduce a resistance force for fixed positions. Detent wheels and detent on-off rotary switches are examples of resistant forces. Some levers require a breakout force to move them from a neutral position. [Pg.474]

Set the multimeter controls (rotary switch or pushbuttons, depending on the particular instrument) to the direct current (dc) milliampere (ma) position, where the maximum amount of current is greater than what is expected in the experiment. If the Radio Shack meter. Catalog Number 22-218 is used, this will be the "150 mA DC" setting, since only about 50 ma is expected. [Pg.25]

If voltage were being measured, the white numbers at the left of the rotary switch show that the 15 could stand for either 15 volts or 150 volts, depending on which setting of the rotary switch is used. But now we are measuring current, and 150 ma is the only thing that could be meant by the black number 15 on the... [Pg.25]

A red clip lead is then attached to the positive terminal of the 9V battery and also to the red metal "probe" of the multimeter. The rotary switch of the meter is set to "150mA DC" (or a similar range if a different kind of meter is used). The black probe of the meter is touched firmly to the other ("upper") end of the 1,000 ohm resistor. On the zero to 15 scale (which now really... [Pg.34]

One example of this type of application is a rotary switch for military radios. Here LCPs were chosen to replace a diallyl phthalate (DAP) thermoset for the stator to solve the problem of high reject rates. Close tolerances down to 0.025 mm must be held on critical areas of the moulding, and the ability to mould thin-walled sections is essential. [Pg.279]

A series of advanced rotary switches has been designed based on good impact resistance, heat resistance to soldering temperature, good insulation properties, solvent resistance and flame retardance. [Pg.451]

On most survey meters a single multi-function rotary switch is used to ... [Pg.241]