Robatel extractor

Robatel extractor, 10 781 Robbins, Frederick, 11 10 Robinson Annulation Reaction, 24 571 Robinson, important experimental design text coverage compared to other texts, 8 395t... [Pg.809]

Podbielniak extractors Oelaval extractor Luwesta extractor Robatel extractor... [Pg.597]

The Robatel extractor is a series of mixer-settlers stacked on their sides, with mixing in each stage being carried out by a stationary disk attached to the shaft while... [Pg.495]

Centrifugal Force Flow through baffles Westfalia Extractor Robatel Extractor Podbielniak Extractor Alfa Laval Extractor... [Pg.367]

Fig. 9.10 (a) Robatel four-stage centrifugal extractor. The heavy and the light liquids... [Pg.388]

The Podbielniak and Alfa Laval centrifugal extractors are essentially continuous differential contactors. The Westfalia and Robatel centrifugal extractors contain discrete mechanical stages, and flow from one to another is effected by spill over discs and skimmers according to usual centrifugal clarifier practice. As the number of discrete stages is increased, the allowable flow rates are proportionately decreased. [Pg.374]

Some solvent-extraction techniques are relatively difficult to effect using conventional laboratory apparatus. For example, the classical penicillin G extraction in which acidified broth is contacted with a water-immiscible solvent can only be operated effectively using continuous-flow methods because of the poor stability of the product at low pH values. This extraction can be reproduced on the bench scale using the AKUFVE apparatus, which was designed for extraction studies in the nuclear industry (12,13). Selective extraction may involve the use of a solvent in which the product has a poor partition coefficient. Countercurrent extractors are mostly process scale devices but the smallest four-stage extractor produced by Robatel could be considered a bench scale. It has a throughput of 50-100 mL/min. [Pg.420]

FI GU RE 5.25 Aqueous and organic flow in a centrifugal extractor (based on Robatel BXP unit). (Adapted from Mooiman, M. B. 1983. Precious metals. Allentown, PA International Precious Metals Institute. With permission.)... [Pg.182]