Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Regional field procedures

Allhough only a few samples may be token on a daily or weekly basis from each sampling site, the total number of samples may be substantial since experimental timeframes may extend over many months. For example, in the comprehensive 2-year national pesticide monitoring program stody by Kutz et al., nearly 2500 samples were collected which individually assessed over 40 individual pesticides and reaction by-products per sample. [Pg.928]

The air sampler manufacturer, who will also supply certification, often performs calibration of certain kinds of air sampling equipment. Air pumps and blowers will always require calibration when used. This involves the use of flow meters certified for accuracy by the manufacturer. In the same way, analytical instrumentation will [Pg.929]

All fortified (spiked) matrix samples are prepared in the laboratory at the same concentration. Laboratory spikes are immediately put into cold storage. Trip and fleld spikes are kept cold and sent to the fleld. The trip spikes will accompany sample shipments. The fleld spikes are stored and transported in the same manner as the trip spikes. When practical, air should be pulled through fleld spikes in the same manner as actual fleld samples being taken at the time of the study. [Pg.930]

For aerosols of nonvolatile pesticides (e.g., paraquat) and aerosols containing pesticides, sampling methods consisting of filtration and employing inertial samplers [Pg.931]

Majewski and P.D. Capel, in Pesticides in the Atmosphere Distribution, Trends, and Governing Factors, ed. R.J. GiUiol, Vol. 1, Pesticides in the Hydrologic System, Ann Arbor Press, Ann Arbor, MI (1995). [Pg.932]


Importantly, all biological procedures are operating at a temperature of 310 Kelvin, not at 0 Kelvin as the potential energy is calculated by the force fields. The kinetic energy must also be considered. Molecules and proteins at room temperature change the conformation at least at the surface and in loop region. Molecular dynamics simulation (MD) is an approach to tackle these kinetic and stability problems. [Pg.779]

The solution of the gas flow and temperature fields in the nearnozzle region (as described in the previous subsection), along with process parameters, thermophysical properties, and atomizer geometry parameters, were used as inputs for this liquid metal breakup model to calculate the liquid film and sheet characteristics, primary and secondary breakup, as well as droplet dynamics and cooling. The trajectories and temperatures of droplets were calculated until the onset of secondary breakup, the onset of solidification, or the attainment of the computational domain boundary. This procedure was repeated for all droplet size classes. Finally, the droplets were numerically sieved and the droplet size distribution was determined. [Pg.363]


See other pages where Regional field procedures is mentioned: [Pg.927]    [Pg.927]    [Pg.789]    [Pg.927]    [Pg.932]    [Pg.222]    [Pg.82]    [Pg.74]    [Pg.317]    [Pg.244]    [Pg.317]    [Pg.77]    [Pg.133]    [Pg.651]    [Pg.1828]    [Pg.726]    [Pg.727]    [Pg.90]    [Pg.66]    [Pg.32]    [Pg.286]    [Pg.110]    [Pg.385]    [Pg.982]    [Pg.276]    [Pg.1452]    [Pg.312]    [Pg.908]    [Pg.924]    [Pg.932]    [Pg.278]    [Pg.45]    [Pg.517]    [Pg.282]    [Pg.206]    [Pg.106]    [Pg.135]    [Pg.179]    [Pg.37]    [Pg.289]    [Pg.93]    [Pg.314]    [Pg.339]   


SEARCH



Field procedures

© 2024 chempedia.info