Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Power analyzer

In running the tests, a power analyzer must be used sueh as the Volteeh PMIOOO, PMI200, or PM3000. Also an audio speetrum analyzer is needed to measure the amplitude of the harmonie eomponents of the ae eurrent. The total input voltage and eurrents are given by... [Pg.224]

From the power analyzer or the speetrum analyzer, one ean measure the amplitude values needed to verify eomplianee to the PFC speeifieations. EN6I000-3-2 has the limits shown in Table C-I. Class A and D are shown beeause they are eommon produet eategories. [Pg.224]

Up to here, the discussion has focused on MALDI-TOF equipment, because MALDI is a pulsed ionization method. MALDI initiated tremendous improvements of TOF analyzers which makes it attractive to combine such compact but powerful analyzers with any other non-pulsed ionization method desirable. The major breakthrough came from the design of the orthogonal acceleration TOF analyzer (oaTOF), i.e., a TOF analyzer into which pulses of ions are extracted or-... [Pg.125]

The case studies in this chapter have shown that algorithms based on the methods depicted in this chapter are able to solve variant problems from various states in the product lifecycle that could not be solved without these. As a consequence, powerful analyzing tools exist that completely and precisely verily complex product models with respect to a diversity of properties involving variants. Furthermore, we expect that models are able to express variant information from other states in the product life cycle and the relations between the states as shown in Fig. 17.9. Examples of other states in the product life cycle are the requirement and market analysis, design, construction, production, logistics, sales and after-sales. [Pg.515]

Powerscope Performance, Productivity and Practicality for Power Disturbance Analysis, 1993. Electric Power Analyzers Tools for Measuring Electric Power Quality, Power Plow, Disturbances, and Demand, 1993. [Pg.65]

If a sample solution is introduced into the center of the plasma, the constituent molecules are bombarded by the energetic atoms, ions, electrons, and even photons from the plasma itself. Under these vigorous conditions, sample molecules are both ionized and fragmented repeatedly until only their constituent elemental atoms or ions survive. The ions are drawn off into a mass analyzer for measurement of abundances and mJz values. Plasma torches provide a powerful method for introducing and ionizing a wide range of sample types into a mass spectrometer (inductively coupled plasma mass spectrometry, ICP/MS). [Pg.87]

Mixtures passed through special columns (chromatography) in the gas phase (GC) or liquid phase (LC) can be separated into their individual components and analyzed qualitatively and/or quantitatively. Both GC and LC analyzers can be directly coupled to mass spectrometers, a powerful combination that can simultaneously separate and identify components of mixtures. [Pg.252]

An added consideration is that the TOF instruments are easily and quickly calibrated. As the mass range increases again (m/z 5,000-50,000), magnetic-sector instruments (with added electric sector) and ion cyclotron resonance instruments are very effective, but their prices tend to match the increases in resolving powers. At the top end of these ranges, masses of several million have been analyzed by using Fourier-transform ion cyclotron resonance (FTICR) instruments, but such measurements tend to be isolated rather than targets that can be achieved in everyday use. [Pg.281]

Accurate mass measurement requires high resolving power. The difference in degrees of difficulty between measuring an m/z of 28 and one of 28.000 is likely to be large. Table 39.3 shows the broad mass ranges achievable with various analyzers. [Pg.281]

By combining a GC instrument with MS, the powerful combination of GC/MS can be used to analyze, both qualitatively and quantitatively, complex mixtures arising from a wide variety of sources. [Pg.415]

Mass resonant analyzer. A mass analyzer for mass-dependent resonant-energy transfer and measurement of the resonance frequency, power, or ion current of the resonant ions. [Pg.429]

The cathode material is stainless steel. The lead produced by this method analyzes 99.99 + %. The overall power consumption is less than 1 kWh/kg of lead, so that the electrolytic process for treating spent batteries has much less of an environmental impact than the conventional pyrometaUurgical process. [Pg.50]


See other pages where Power analyzer is mentioned: [Pg.277]    [Pg.54]    [Pg.306]    [Pg.39]    [Pg.39]    [Pg.436]    [Pg.587]    [Pg.926]    [Pg.585]    [Pg.1286]    [Pg.597]    [Pg.490]    [Pg.132]    [Pg.706]    [Pg.708]    [Pg.277]    [Pg.54]    [Pg.306]    [Pg.39]    [Pg.39]    [Pg.436]    [Pg.587]    [Pg.926]    [Pg.585]    [Pg.1286]    [Pg.597]    [Pg.490]    [Pg.132]    [Pg.706]    [Pg.708]    [Pg.553]    [Pg.503]    [Pg.4]    [Pg.573]    [Pg.589]    [Pg.185]    [Pg.278]    [Pg.281]    [Pg.547]    [Pg.26]    [Pg.417]    [Pg.335]    [Pg.401]    [Pg.402]    [Pg.305]    [Pg.130]    [Pg.276]    [Pg.180]    [Pg.1827]    [Pg.2040]   
See also in sourсe #XX -- [ Pg.39 ]

See also in sourсe #XX -- [ Pg.39 ]

See also in sourсe #XX -- [ Pg.39 ]




SEARCH



Example Analyzing an Emergency Electric Power System

Mass analyzers representative resolving powers

Mass analyzers resolving power

© 2024 chempedia.info