Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Polymer solutions order

The reversible aggregation of monomers into linear polymers exhibits critical phenomena which can be described by the 0 hmit of the -vector model of magnetism [13,14]. Unlike mean field models, the -vector model allows for fluctuations of the order parameter, the dimension n of which depends on the nature of the polymer system. (For linear chains 0, whereas for ring polymers = 1.) In order to study equilibrium polymers in solutions, one should model the system using the dilute 0 magnet model [14] however, a theoretical solution presently exists only within the mean field approximation (MFA), where it corresponds to the Flory theory of polymer solutions [16]. [Pg.510]

In order to begin this presentation in a logical manner, we review in the next few paragraphs some of the general features of polymer solution phase equilibrium thermodynamics. Figure 1 shows perhaps the simplest liquid/liquid phase equilibrium situation which can occur in a solvent(l)/polymer(2) phase equilibrium. In Figure 1, we have assumed for simplicity that the polymer involved is monodisperse. We will discuss later the consequences of polymer polydispersity. [Pg.181]

From the outset, Flory (6) and Huggins (4,5 ) recognized that their expressions for polymer solution thermodynamics had certain shortcomings (2). Among these were the fact that the Flory-Huggins expressions do not predict the existence of the LCST (see Figure 2) and that in practice the x parameter must be composition dependent in order to fit phase equilibrium data for many polymer solutions 3,8). [Pg.186]

These two examples show that regular patterns can evolve but, by definition, dissipative structures disappear once the thermodynamic equilibrium has been reached. When one wants to use dissipative structures for patterning of materials, the dissipative structure has to be fixed. Then, even though the thermodynamic instability that led to and supported the pattern has ceased, the structure would remain. Here, polymers play an important role. Since many polymers are amorphous, there is the possibility to freeze temporal patterns. Furthermore, polymer solutions are nonlinear with respect to viscosity and thus strong effects are expected to be seen in evaporating polymer solutions. Since a macromolecule is a nanoscale object, conformational entropy will also play a role in nanoscale ordered structures of polymers. [Pg.191]

The acidic conditions of standard SBA-15 synthesis [35] cause the precipitation of metal nanoparticles without silica encapsulation, or the formation of amorphous silica due to the presence of the polymer used for nanoparticle synthesis. Therefore, the SBA-15 framework was synthesized under neutral condition using sodium fluoride as a hydrolysis catalyst and tetramethylorthosilicate (TMOS) as the silica precursor. Pt particles with different sizes were dispersed in the aqueous template polymer solution sodium fluoride and TMOS were added to the reaction mixture. The slurry aged at 313 K for a day, followed by an additional day at 373 K. Pt(X)/SBA-15-NE (X = 1.7, 2.9, 3.6, and 7.1nm) catalysts were obtained by ex-situ calcination (see Section 3.2). TEM images of the ordered... [Pg.157]

In order to understand polymer solution behaviour, the samples have to be characterised with respect to their molecular configuration, their molar mass and polydispersity, the polymer concentration and the shear rate. Classical techniques of polymer characterisation (light scattering, viscometry, ultracentrifugation, etc.) yield information on the solution structure and conformation of single macromolecules, as well as on the thermodynamic interactions with the solvent. In technical concentrations the behaviour of the dissolved polymer is more complicated because additional intramolecular and intermolecular interactions between polymer segments appear. [Pg.8]

Using this equation an attempt was made to find a critical Re-number which could be correlated to the onset of vortices observed with the naked eye, as has been done, for example, for Newtonian fluids [93], but no correlation could be found [88]. The reason is probably due to the fact that polymer solutions are viscoelastic fluids, also called second-order fluids. [Pg.39]

The recent interest in substituted silane polymers has resulted in a number of theoretical (15-19) and spectroscopic (19-21) studies. Most of the theoretical studies have assumed an all-trans planar zig-zag backbone conformation for computational simplicity. However, early PES studies of a number of short chain silicon catenates strongly suggested that the electronic properties may also depend on the conformation of the silicon backbone (22). This was recently confirmed by spectroscopic studies of poly(di-n-hexylsilane) in the solid state (23-26). Complementary studies in solution have suggested that conformational changes in the polysilane backbone may also be responsible for the unusual thermochromic behavior of many derivatives (27,28). In order to avoid the additional complexities associated with this thermochromism and possible aggregation effects at low temperatures, we have limited this report to polymer solutions at room temperature. [Pg.61]

Hydrolysis rate measurements. Hydrolysis rates were examined by mixing polymer solutions with hydrochloric acid, in apparatus previously described (5). Solutions of polymer and acid are mixed rapidly, and the torque on a rotating PTFE coated fork, attached to a Brookfield LVTD viscometer, recorded as a function of time. Decreases in viscosity were approximated to first-order, and half-lives for viscosity loss calculated. [Pg.164]

In order to be truly useful, it must be possible to compute polymer chain information, namely average mean squared end-to-end distances. These can be directly compared to polymer solution data if available and also provide information on bulk properties. [Pg.34]

Figure 11(A) shows a principle sketch of a SEC set-up. The eluent (solvent) is pumped at a constant flow rate through the system. A small amount of polymer solution (typically 200 pL) is injected manually or with an autosampler. The main part comprises a set of columns (typically 3-4 columns+pre-column) typically packed with microporous styrene-divinylbenzene, porous glass, or silica. In the routine analytical laboratory it is especially useful to have a pre-column in order to collect impurities that might be present in the samples. If many different samples are to be analyzed, it is necessary to check the reliability of the columns frequently to avoid artefacts due to residues from previous samples still held on the column. In order to avoid problems, samples should be purified before they... Figure 11(A) shows a principle sketch of a SEC set-up. The eluent (solvent) is pumped at a constant flow rate through the system. A small amount of polymer solution (typically 200 pL) is injected manually or with an autosampler. The main part comprises a set of columns (typically 3-4 columns+pre-column) typically packed with microporous styrene-divinylbenzene, porous glass, or silica. In the routine analytical laboratory it is especially useful to have a pre-column in order to collect impurities that might be present in the samples. If many different samples are to be analyzed, it is necessary to check the reliability of the columns frequently to avoid artefacts due to residues from previous samples still held on the column. In order to avoid problems, samples should be purified before they...

See other pages where Polymer solutions order is mentioned: [Pg.2365]    [Pg.251]    [Pg.307]    [Pg.65]    [Pg.198]    [Pg.201]    [Pg.65]    [Pg.440]    [Pg.334]    [Pg.44]    [Pg.557]    [Pg.28]    [Pg.565]    [Pg.603]    [Pg.428]    [Pg.100]    [Pg.174]    [Pg.377]    [Pg.442]    [Pg.313]    [Pg.81]    [Pg.87]    [Pg.283]    [Pg.309]    [Pg.519]    [Pg.520]    [Pg.193]    [Pg.172]    [Pg.94]    [Pg.390]    [Pg.276]    [Pg.215]    [Pg.424]    [Pg.145]    [Pg.244]    [Pg.451]    [Pg.452]    [Pg.174]    [Pg.28]    [Pg.443]   
See also in sourсe #XX -- [ Pg.282 ]




SEARCH



Ordered solution

Solute order

© 2024 chempedia.info