Polydimethylsiloxanes determinations

Solid-phase microextraction (SPME) consists of dipping a fiber into an aqueous sample to adsorb the analytes followed by thermal desorption into the carrier stream for GC, or, if the analytes are thermally labile, they can be desorbed into the mobile phase for LC. Examples of commercially available fibers include 100-qm PDMS, 65-qm Carbowax-divinylbenzene (CW-DVB), 75-qm Carboxen-polydimethylsiloxane (CX-PDMS), and 85-qm polyacrylate, the last being more suitable for the determination of triazines. The LCDs can be as low as 0.1 qgL Since the quantity of analyte adsorbed on the fiber is based on equilibrium rather than extraction, procedural recovery cannot be assessed on the basis of percentage extraction. The robustness and sensitivity of the technique were demonstrated in an inter-laboratory validation study for several parent triazines and DEA and DIA. A 65-qm CW-DVB fiber was employed for analyte adsorption followed by desorption into the injection port (split/splitless) of a gas chromatograph. The sample was adjusted to neutral pH, and sodium chloride was added to obtain a concentration of 0.3 g During continuous... [Pg.427]

The concept of SPME was first introduced by Belardi and Pawliszyn in 1989. A fiber (usually fused silica) which has been coated on the outside with a suitable polymer sorbent (e.g., polydimethylsiloxane) is dipped into the headspace above the sample or directly into the liquid sample. The pesticides are partitioned from the sample into the sorbent and an equilibrium between the gas or liquid and the sorbent is established. The analytes are thermally desorbed in a GC injector or liquid desorbed in a liquid chromatography (LC) injector. The autosampler has to be specially modified for SPME but otherwise the technique is simple to use, rapid, inexpensive and solvent free. Optimization of the procedure will involve the correct choice of phase, extraction time, ionic strength of the extraction step, temperature and the time and temperature of the desorption step. According to the chemical characteristics of the pesticides determined, the extraction efficiency is often influenced by the sample matrix and pH. [Pg.731]

Fig. 2. Relaxation modulus G(t) of a set of polydimethylsiloxane samples with increasing extent of crosslinking plotted against time of crosslinking. The linear PDMS chains (Mn 10 000, polydis-persity index 2) were endlinked with a four-functional silane crosslinker catalyzed by a platinum compound. Samples with different extent of reaction were prepared by poisoning the reaction at different times. The actual extent of reaction was not determined. Two of the samples are clearly before the gel point (LST) and two beyond. The third sample is very close to the gel point. Data of Chambon and Winter [5] evaluated by Baumgartel and Winter [8]... Fig. 2. Relaxation modulus G(t) of a set of polydimethylsiloxane samples with increasing extent of crosslinking plotted against time of crosslinking. The linear PDMS chains (Mn 10 000, polydis-persity index 2) were endlinked with a four-functional silane crosslinker catalyzed by a platinum compound. Samples with different extent of reaction were prepared by poisoning the reaction at different times. The actual extent of reaction was not determined. Two of the samples are clearly before the gel point (LST) and two beyond. The third sample is very close to the gel point. Data of Chambon and Winter [5] evaluated by Baumgartel and Winter [8]...
From a theoretical point of view, the equilibrium modulus very probably gives the best characterization of a cured rubber. This is due to the relationship between this macroscopic quantity and the molecular structure of the network. Therefore, the determination of the equilibrium modulus has been the subject of many investigations (e.g. 1-9). For just a few specific rubbers, the determination of the equilibrium modulus is relatively easy. The best example is provided by polydimethylsiloxane vulcanizates, which exhibit practically no prolonged relaxations (8, 9). However, the networks of most synthetic rubbers, including natural rubber, usually show very persistent relaxations which impede a close approach to the equilibrium condition (1-8). [Pg.517]

Food Additives and Contaminants 20, No.5, May 2003, p.438-44 DETERMINATION OF POLYDIMETHYLSILOXANES BY PROTON-NMR IN WINE AND EDIBLE OILS Mojsiewicz-Pienkowska K Jamrogiewicz Z Lukasiak J Gdansk,Medical University... [Pg.41]

Boyd-Boland and Pawliszyn [77] pioneered the SPME analysis of APEOs by SPME-HPLC using normal-phase gradient elution with detection by UV absorbance at 220 nm. The Carbowax-template resin (CW-TR) and Carbowax-divinylbenzene (CW-DVB) fibres allowed the analysis of APEO with a linear range of 0.1-100 mg L 1. The former coating produced the best agreement between the distribution of ethoxymers before and after extraction. This CW-TR fibre provided a limit of detection for individual AP ethoxamers at the low ppb level. The determination of NP in water by SPME-GC (FID) was accomplished by Chee et al. [78] using a polydimethylsiloxane (PDMS) fibre. The linear range was between 1 and 15 mg L 1 with an estimated detection limit of 0.1 mg L-1. [Pg.431]

An atomic absorption method was published by AOAC Int. (2000) for determination of the anti-foaming agent polydimethylsiloxane in pineapple juice, that is based on extraction with 4-methyl-2-pentanone and aspiration into a nitrous oxide/acetylene flame. A silicone lamp was used for detection. [Pg.126]

Nitrobenzene, 2,4-dinitrotoluene and 2,6-dinitrotoluene were determined in water by GC-EC or GC-CLD thermal energy analyzer (TEA) and by EI-MS, CI-MS and NICI-MS455, after solid-phase microextraction (SPME) with polydimethylsiloxane coated fiber. SPME is a technique to concentrate organic compounds dissolved in an aqueous matrix by adsorption on a solid stationary phase immobilized on a fused silica fiber. The analytes were thermally desorbed directly into the GC injector LOD was 9 pg/L for nitrobenzene and 15 pg/L for the dinitrotoluenes456. [Pg.1127]

Determination of Functional Groups in Molecular Components of Polydimethylsiloxanes... [Pg.169]

In this paper detailed methods for the determination of placement and assay of silicon hydride (Si-H), silicon hydroxide (Si-OH) and silicon phenyl (Si-0) functional groups in molecular weight components of silicones of the Sylgard (Dow-Corning Co.) type will be described. The methods are illustrated with the analysis of Sylgard addition prepolymers and of model polydimethylsiloxanes (PDMS). [Pg.170]

A method was described for the accurate and precise determination of monomethyl-Hg by species sped Pc isotope dilution calibration using SPME in combination with GC separation and ICP-MS detection [46], Samples were digested with methanolic KOH, derivatized in aqueous solution with sodium tetra-propylborate and headspace sampled with a polydimethylsiloxane SPME fused silica Pber. The analyte was then directly transferred from the Pber to the head of the GC column for desorption. [Pg.28]

Allen et al. (1960) used ultraviolet spectrometry to determine phase compositions in a polymer-polymer-solvent system containing polystyrene and polyisobutylene. At a wavelength of 250-260 nm, polystyrene has a strong adsorption band, which is linearly related to concentration, while polyisobutylene is transparent. Similarly, for a system containing polydimethylsiloxane and polyisobutylene, they used infrared spectrometry because poly-dimethylsiloxane absorbs at 1261 cm 1 and polyisobutylene is transparent at this wavelength. UVS and IRS have been used with other systems which contain only one polymer which has a strong adsorption band. [Pg.92]

Hammers, W. E. De Ligny, C. L., "Determination of the Flory-Huggins X Parameter, the Heat of Dilution, and the Excess Heat Capacity of Some Alkanes in Polydimethylsiloxane by Gas Chromatography," J. Polym. Sci., Polym. Phys. Ed., 12, 2065 (1974). [Pg.172]

Retention of Rohrschneider-McReynolds standards of selected chiral alcohols and ketones was measured to determine the thermodynamic selectivity parameters of stationary phases containing (- -)-61 (M = Pr, Eu, Dy, Er, Yb, n = 3, R = Mef) dissolved in poly(dimethylsiloxane) . Separation of selected racemic alcohols and ketones was achieved and the determined values of thermodynamic enantioselectivity were correlated with the molecular structure of the solutes studied. The decrease of the ionic radius of lanthanides induces greater increase of complexation efficiency for the alcohols than for the ketone coordination complexes. The selectivity of the studied stationary phases follows a common trend which is rationalized in terms of opposing electronic and steric effects of the Lewis acid-base interactions between the selected alcohols, ketones and lanthanide chelates. The retention of over fifty solutes on five stationary phases containing 61 (M = Pr, Eu, Dy, Er, Yb, n = 3, R = Mef) dissolved in polydimethylsiloxane were later measured ". The initial motivation for this work was to explore the utility of a solvation parameter model proposed and developed by Abraham and coworkers for complexing stationary phases containing metal coordination centers. Linear solvation... [Pg.721]


See other pages where Polydimethylsiloxanes determinations is mentioned: [Pg.729]    [Pg.729]    [Pg.49]    [Pg.555]    [Pg.560]    [Pg.32]    [Pg.63]    [Pg.184]    [Pg.77]    [Pg.171]    [Pg.42]    [Pg.252]    [Pg.88]    [Pg.98]    [Pg.540]    [Pg.169]    [Pg.303]    [Pg.15]    [Pg.307]    [Pg.2236]    [Pg.195]    [Pg.175]    [Pg.77]    [Pg.172]    [Pg.174]    [Pg.275]    [Pg.179]    [Pg.719]    [Pg.46]    [Pg.183]    [Pg.303]    [Pg.26]    [Pg.509]    [Pg.626]    [Pg.250]    [Pg.49]    [Pg.49]   