Phase separation collection equipment

Allow phase separation, collect the upper hexane layer with the aid of a glass Pasteur pipette and transfer the sample into a glass 10-ml tube equipped with a screw cap. [Pg.227]

Solvent Process. In the solvent process, or solvent cook, water formed from the reaction is removed from the reactor as an a2eotropic mixture with an added solvent, typically xylene. Usually between 3 to 10 wt % of the solvent, based on the total charge, is added at the beginning of the esterification step. The mixed vapor passes through a condenser. The condensed water and solvent have low solubiUty in each other and phase separation is allowed to occur in an automatic decanter. The water is removed, usually to a measuring vessel. The amount of water collected can be monitored as one of the indicators of the extent of the reaction. The solvent is continuously returned to the reactor to be recycled. Typical equipment for this process is shown in Figure 2. The reactor temperature is modulated by the amount and type of refluxing solvent. Typical conditions are ... [Pg.39]

These operations may sometimes be better kno Ti as mist entrainment, decantation, dust collection, filtration, centrifugation, sedimentation, screening, classification, scrubbing, etc. They often involve handling relatively large quantities of one phase in order to collect or separate the other. Therefore the size of the equipment may become very large. For the sake of space and cost it is important that the equipment be specified and rated to Operate as efficiently as possible [9]. This subject will be limited here to the removal or separation of liquid or solid particles from a vapor or gas carrier stream (1. and 3. above) or separation of solid particles from a liquid (item 4j. Reference [56] is a helpful review. [Pg.224]

In some circumstances, separation of solid from a liquid is better achieved by use of a centrifuge than by filtration, and a small, electrically driven centrifuge is a useful piece of equipment for an analytical laboratory. It may be employed for removing the mother liquor from recrystallised salts, for collecting difficultly filterable precipitates, and for the washing of certain precipitates by decantation. It is particularly useful when small quantities of solids are involved centrifuging, followed by decantation and re-centrifuging, avoids transference losses and yields the solid phase in a compact form. Another valuable application is for the separation of two immiscible phases. [Pg.103]

Separation of components occurs as the analytes and mobile phase are pumped through the column. Eventually, each component elutes from the column as a narrow band or peak on the recorder. Detection of the eluting components is important, and this can be either selective or universal, depending upon the detector used. Tlte response of the detector to each component is displayed on a chart recorder or computer screen and is known as a chromatogram. To collect, store, and analyze chromatograms, computers, integrators, and other data processing equipment are frequently used. [Pg.665]


See other pages where Phase separation collection equipment is mentioned: [Pg.163]    [Pg.420]    [Pg.183]    [Pg.15]    [Pg.16]    [Pg.253]    [Pg.997]    [Pg.1368]    [Pg.47]    [Pg.1367]    [Pg.532]    [Pg.578]    [Pg.1178]    [Pg.47]    [Pg.222]    [Pg.1786]    [Pg.15]    [Pg.16]    [Pg.247]    [Pg.255]    [Pg.243]    [Pg.229]    [Pg.1174]    [Pg.2014]    [Pg.414]    [Pg.29]    [Pg.28]    [Pg.421]    [Pg.260]    [Pg.366]    [Pg.264]    [Pg.149]    [Pg.161]    [Pg.197]    [Pg.73]    [Pg.21]    [Pg.64]    [Pg.664]    [Pg.214]    [Pg.126]    [Pg.299]    [Pg.201]    [Pg.2]   