Pensky-Martens closed cup

Pensky-Martens closed cup unless otherwise noted. Cleveland open cup. [Pg.445]

Determined by ASTM D92, using the Pensky-Martens closed cup. ... [Pg.356]

Closed cup unless otherwise specified. PMCC = Pensky-Martens closed cup COC ... [Pg.278]

Methods of test for petroleum and its products. Determination of flash point. Pensky-Martens closed cup method. [Pg.398]

Hughes, J.M., Hardy, D.R., and Beal, EJ. A flash point value for n-dodecane based on the manual Pensky-Martens closed cup method (ASTM-D-93), Energy Fuels, 10(6) 1276-1277, 1996. [Pg.1671]

Flash Point by Pensky-Martens Closed Cup Tester Saponification Number of Petroleum Products Pour Point of Petroleum Products... [Pg.353]

BSI 1998b. Methods of Analysis of Fats and Fatty Oils, Part 1. Physical Methods, Section 1.17. Flashpoint limit test using Pensky-Martens closed-cup flash tester, British Standards Institution, London. [Pg.773]

Flash Point-Pensky-Martens Closed Cup for Fats and Oils (Cc 9b-55) determines the temperature at which an oil sample will flash when a test flame is applied. This technique sometimes is used to estimate levels of residual hexane and to ensure the safety of workers handling the oil. Some refineries use gas chromatography methods instead. [Pg.1648]

Closed cup unless otherwise specified. PMCC = Pensky-Martens closed cup COC PEL = personal exposure limit LEL = lower exposure limit UEL = upper exposure Ceiling limit is the concentration that should not be exceeded during any part of the working exposure relative vs -butyl acetate = 1. Relative to air = 1. [Pg.278]

ASTM D 3278-96, Standard test methods for flash point of liquids by setaflash closed-cup apparatus ASTM D 0093-96, Standard test methods for flash point by Pensky-Martens closed cup tester... [Pg.71]

ASTM D93-02. Standard Test Methods for Flashpoint by Pensky-Martens Closed Cup Tester, ASTM International West Conshohocken, PA, USA, 2002 Edition. [Pg.1118]

Method 1P34. Determination of Idash Point - Pensky Martens Closed Cup Method. IP Standard Methods for Analysis and Testing of Petroleum and Related Products and British Standard 2000 Parts. Energy Institute. [Pg.372]

It is a liquid, other than an aqueous solution containing less than 24 percent alcohol by volume and has flash point less than 60°C (140°F), as determined by a Pensky-Martens Closed Cup Tester, using the test method specified in ASTM Standard D-93-79 or D-93-80 or a Setaflash Closed Cup Tester, using the test method specified in ASTM Standard D-3278-78, or as determined by an equivalent test method approved by the Administrator. ... [Pg.106]

PMCC Pensky-Martens closed cup SADT self accelerating decomposition temp. [Pg.1791]

DIN EN ISO 2719 2003-09 (2002) Determination of flash point—Pensky-Martens closed cup method (ISO 2719 2002) German version EN ISO 2719 2002... [Pg.66]

Note Flash points are determined by the ASTM Pensky-Martens Closed Cup Method and fire points by the ASTM Cleveland Open Cup Method. [Pg.420]

Melting point Cleveiand open cup Pensky Martens closed cup Flash points measured by the closed cup method. ASTM D-56 ... [Pg.581]

A variety of apparatus such as the small scale closed tester, flic tag open cup, the tag closed tester,the Cleveland open cup, the Pensky-Martens closed cup, and the equilibrium method are used to determine the flash point. The selection of method is based suggestions included in separate standard. ... [Pg.1060]

The Cleveland open cup is placed on a heated plate which increases temperature at a rate of 5-6 C/min. This method can also be automated. The method is designed for testing petroleum products which are viscous and have flash point above 79"C. The Pensky-Martens closed cup tester was also designed for petroleum products but for those with flash points from 40 to 360 C. This apparatus has its own heating source, stirrer, and cover by which it differs from Cleveland cup. It can be either manual or automated. The equihbrium method uses eiflier a modified tag close cup or the Pensky-Martens apparatus. The modification intended to keep flic vapor/air temperature in equilibrium with the liquid temperature. The method is limited to the temperature range from 0 to 110 C. [Pg.1060]

ASTM D 93. Standard test methods for flash-point by Pensky-Martens closed cup tester. [Pg.1073]

Fig. 3.14 Closed cups for flash point determination a Abel s closed cup b Pensky-Martens closed cup c Tag s closed cup. Dimensions in mm... Fig. 3.14 Closed cups for flash point determination a Abel s closed cup b Pensky-Martens closed cup c Tag s closed cup. Dimensions in mm...

See other pages where Pensky-Martens closed cup is mentioned: [Pg.346]    [Pg.356]    [Pg.29]    [Pg.138]    [Pg.346]    [Pg.356]    [Pg.356]    [Pg.234]    [Pg.56]    [Pg.154]    [Pg.56]    [Pg.163]    [Pg.278]    [Pg.900]    [Pg.340]    [Pg.497]    [Pg.576]    [Pg.753]    [Pg.12]    [Pg.7176]    [Pg.7178]    [Pg.228]    [Pg.582]    [Pg.582]   