Peak pick

On the basis of automated peak picking and integration procedure, after less than 2 h, the enantiomeric purity was established. R S ratio was 34.4 65.6, which is close to the values obtained from the 1H or 13C NMR spectra. [Pg.129]

The simplicity and clarity of CONCISE has been retained in the automated rule generator which creates CONCISE interpretation rules for PAIRS based on a representative set of IR spectra. The rule generator uses peak position, intensity, and width tables produced by an automated peak picking routine. This method reduces the dependency on published frequency correlation data and enhances the usefulness of data already available. All work was done using the version of PAIRS running on a Nicolet 1180 minicomputer and programs generated have been optimized for this system. [Pg.313]

An E-map is computed for the best set and the peaks picked. We then use our knowledge of molecular dimensions and conformations to extract a trial structure. This is the first point at which chemical knowledge is used actively i.e. the direct methods procedure is model free until this point. The structure is completed and refined in the usual way. [Pg.329]

Peak-picking appears to be a domain largely occupied by instrument manufacturers. As a consequence, many of the algorithms remain unpublished. [Pg.220]

The role of peak-picking is to return only one position per peak, and in the presence of noise, this again poses problems. It is likely that most algorithms will start from a position of intensity maximum, and then search either side for the first point significantly lower, i.e., a multiplier of the noise. This defines a new peak region and the process could then be repeated. Some software additionally offers the facility of a horizontal threshold, above which values are returned and below which they are not. [Pg.220]

Zero filling the FID more than a factor of two does not contribute to information extraction and any features revealed by this are artefacts. In most instances, zero filling by a factor of two amounts to an interpolation procedure benefiting primarily peak-picking. There are other procedures which can allow peak-picking interpolation between data points and the one used by the author is a simple equation to fit the maximum intensity and one point either side to a parabola and compute the position of its maximum. Bruker peak-pick table positions for instance are not separated by a multiple of the digital resolution and it would seem that they use the same or an analogous procedure. [Pg.220]

Wiithrich et al published a tour de force on the Automated Peak-Picking and Peak Integration in Macromolecular Spectra (AUTOPSY). This work deals primarily with two-dimensional spectra, but the algorithms are equally... [Pg.220]

In the retesting and deconvolution phase of the procedure new compound mixtures were made based on the results of primary screening. These contained from nine to 14 compounds and no monoisotopic mass redundancy. Since most mass spectrometric peaks picked as hits in the primary screen contain more than one compound, and only one compound per peak is likely to be a binder, the nonmass redundant retest mixtures are unlikely to contain more than a few bona fide ligands, so once again target excess is maintained. Both the initial (round zero,... [Pg.167]

There are four general modes of operation for LC-NMR on-flow, direct stop-flow, time-sliced and loop collection/transfer. The mode selected will depend on the level and complexity of the analyte and also on the NMR information required. All modes of LC-NMR can be run under full automation for LC peak-picking, LC peak transfer to storage loops or NMR flow cell, and NMR detection [46],... [Pg.196]

Analysis This pull-down menu is only available for frequency domain data (spectra) and allows a few simple analytical tasks to be performed such as peak picking, calibration, integration or simple spectral analysis. [Pg.84]

Starts peak picking using the parameter PC last set during interactive peak picking (see section 4.6.2). [Pg.90]

Load the H spectrum of glucose D NMRDATA GLUCOSE 1D H GH 002999.1 R. Use the Peak Picking button in the button panel for peak picking. From the Display pull-down menu choose the Display Colors menu. In the dialog box that appears on the screen select different colors for the spectrum, the frame, the numbers and the peak labels. Peak picking will be explained in more detail in section 4.6.2. [Pg.94]

Peak picking is usually performed to measure chemical shifts (in ppm relative to a reference peak in the spectrum) or to measure line separations (in Hz) in multiplets in order to calculate or at least to estimate coupling constants. [Pg.98]

The Peak Picking option in the Analysis pull-down menu allows peak picking in an interactive way. Activating this menu option switches the button panel into the Peak Picking mode, the mouse cursor to Peak Picking Zoom mode and opens a dialog box (Fig. 4.10). [Pg.98]

In this dialog box the Peaks sign, the Peaks Label and the parameter PC, which determines the sensitivity of the peak picking algorithm may be specified. Furthermore, the Interpolation and Multiplicity mode can be set which increases the accuracy of the peak picking and lists the multiplicity information respectively. [Pg.98]

The buttons in the peak picking button panel have several functions ... [Pg.98]

The Mouse Peak Picking mode allows you to define the x-and y-limits for the peak picking regions (Fig. 4.11). It is possible to pick peaks in many different regions of the spectrum using this option. [Pg.98]

A dialog box allows you to inspect and edit the peak picking parameters. [Pg.98]

A dialog box allows you to list, edit, load and save peak picking regions and to execute peak picking according to the entries. [Pg.98]

Erases all the individual peak picking regions and all the picked labels. A region is created that spans the complete spectrum. [Pg.98]

Relax.-> Allows the Peak Picking mode to be carried over into the Peak Picking -Relaxation mode. For peak picking in connection with relaxation studies, you are referred to Modern Spectral Analysis (volume 3 of this series). [Pg.99]

Fig. 4.11 Peak picking in the Mouse Peak Picking mode. Fig. 4.11 Peak picking in the Mouse Peak Picking mode.

See other pages where Peak pick is mentioned: [Pg.39]    [Pg.39]    [Pg.217]    [Pg.218]    [Pg.219]    [Pg.220]    [Pg.222]    [Pg.230]    [Pg.318]    [Pg.135]    [Pg.135]    [Pg.135]    [Pg.135]    [Pg.216]    [Pg.79]    [Pg.80]    [Pg.90]    [Pg.92]    [Pg.98]    [Pg.98]    [Pg.98]    [Pg.99]    [Pg.100]   
See also in sourсe #XX -- [ Pg.135 ]




SEARCH



Peak picking

Peak picking

Peak picking algorithm

Peak picking problem

Peak picking resonance assignment

Peak picking, automated

Picks

Processing peak picking

© 2024 chempedia.info