Panel fans A simple form of axial fan with its impeller mounted in a ring or diaphragm it discharges air both axially and radially. [Pg.1465]

Used for aircraft fuel tanks, storm shutters, refrigerator liners, utensils, electronic mounting plates and panels, fan blades... [Pg.176]

Figure 12-125. Square panel, v-belt drive propeller fan. (Used by permission The New York Blower Co. For more information, contact the company at www.nyb.com.)... Figure 12-125. Square panel, v-belt drive propeller fan. (Used by permission The New York Blower Co. For more information, contact the company at www.nyb.com.)...
A starter or contactor with manual push-button or thermostatic operation to start and stop the fan normally controls simple systems. More complex systems that incorporate components that need control or monitoring are normally operated from purpose-built central control panels. The most common functions provided are fan motor stop, start and speed control, damper control, filter-condition indication and heater battery control. For optimum control, the system should be automatically controlled from thermostats or other sensors and a timeswitch. [Pg.423]

Check electrical connections between panel and fans. [Pg.432]

Filter life varies with make and type, and may be limited by the ability of the fan to operate against pressure drop. It is a function of the dirtiness of the air and the amount of material packed into the filter bank. Life may be quoted in terms of dust held in g/m face area. For fan selection knowledge of pressure drop is required. Typically, a panel filter might be quoted as operating from, say, 75 Pa initially at 2.5 m/s face velocity to 250 Pa when loaded and a HEPA might operate up to 700 Pa. The pressure drop... [Pg.451]

Check water analysis the frequency depends on individual cases but it should be no less than quarterly. Check mechanical equipment (i.e. fans, motors, drives). (Remember to check belt tensions where applicable.) Check for vibration, both mechanically and structurally. Ensure that access panels are used and replaced correctly. [Pg.536]

There are dampers bottom and top of this cladding cavity to promote natural ventilation. A few integrated photo-voltaic panels are sufficient to power the fans (twelve V2-HP motors) that assist ventilation through the double skin. There are tracks within the double skin that assist in the cleaning of surfaces 2 and 3. There is also a grid of fibre optic lights that blink periodically and change colour. [Pg.128]

Fan motors should be sized at 25% above the brake horsepower. Fans should be belt driven with variable pitch drives up to and including 25 FIP and fixed pitch drives at about 25 FIP. Fans must be radial and they must be balanced (static and dynamic) and mounted on anti-vibration supports. The connection of the fan outlet to the inside panels must be done by means of an internal flexible connector. [Pg.46]

Glass-reinforced SMA polymers are used as electrical connectors, consoles, top pads, and as supports for urethane-padded instrument panels. There are seveial additional automotive uses. SMA aie also found in coffee makers, steam curlers, power tools, audio cassette components, business machines, vacuum cleaners, solar heat collectors, electrical housing, and fan blades, among others. [Pg.1557]

In an enclosure that operates under slightly negative pressure, or in one that goes to negative pressure when a gas is detected and fans or blowers start, at least one of the escape doors should open inward. Negative pressure inside the enclosure will make opening the door more difficult in an emergency. A knock-in panel in the door will help circumvent this drawback. [Pg.101]

Estimation of the Ciroulation Fan Power for the Water Base Paint. Consider first the heat input required for the metal, the water removal, the end losses and the oven panel losses. Call this Q, made up of ... [Pg.69]

During our inspection, we noted that most of the fume hoods were in a state of serious disrepair. We found units that were missing interior panels and covers and as a result leaked contaminants. We found hoods with malfunctioning or inoperative ventilation fans. We also observed hoods vented through duct work that was perforated. Finally, we also found... [Pg.148]


See other pages where Panel fans is mentioned: [Pg.1255]    [Pg.385]    [Pg.293]    [Pg.247]    [Pg.1216]    [Pg.126]    [Pg.474]    [Pg.484]    [Pg.159]    [Pg.13]    [Pg.12]    [Pg.23]    [Pg.1080]    [Pg.407]    [Pg.118]    [Pg.107]    [Pg.192]    [Pg.180]    [Pg.383]    [Pg.391]    [Pg.44]    [Pg.385]    [Pg.9]    [Pg.32]    [Pg.159]    [Pg.345]    [Pg.249]    [Pg.1039]    [Pg.385]    [Pg.63]    [Pg.331]    [Pg.363]    [Pg.1381]    [Pg.1382]    [Pg.60]   