Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Oxidatively modified immunoglobulin

it is important to realize that just because there is no change in the spectrum does not necessarily mean no change in the overall secondary structure of the protein. For example, a polypeptide chain scission may take place inducing a break in a disordered region, leaving individual separate portions of secondary structure intact. [Pg.216]

An advantage of this technique is that an external probe molecule is not required and the absorption of the protein groupings reflect their genuine environments. Techniques such as fluorescence are limited, to a certain extent, by the perturbation which added probes may induce. [Pg.216]

The timescale of molecular vibrations of IR spectroscopy is of the order of 1013 s-1 which ideally complements those of ESR and NMR, 10s s—1 and 105 s, respectively. [Pg.216]

The principal advantage of FTIR compared with normal dispersive spectrometers is that spectra of higher signal-to-noise ratio in [Pg.216]

Disadvantages are that the single-beam FTIR usually has inferior ordinate stability compared with a double-beam dispersive instrument and the moving mirror is extremely sensitive to vibration. [Pg.218]


When poly(ethylene oxide) (PEO) silane was grafted onto oxidized PDMS stamps it acts as a protein repellent layer. This property was utilized to design a flat stamp with regions that can attract proteins (nonmodified PDMS) and regions modified with PEO that have protein-repellent properties. The local modification of native PDMS was conducted by oxidation in 02-plasma with the application of a metal mask (areas that were covered by the mask were not oxidized and not modified). Proteins (immunoglobulin G, IgG) were transferred successfully to the glass substrates... [Pg.450]

Immunoglobulin type, reactivity with chemically modified antigens, and carbohydrate content of antibodies may also be determined. In determination of the Ig type it was found that all antibodies react with goat antirabbit IgG and not against rabbit IgA or IgM. The antibodies are therefore of the IgG type of immunoglobulin.37 Periodate oxidation, oxidation by... [Pg.208]


See other pages where Oxidatively modified immunoglobulin is mentioned: [Pg.216]    [Pg.216]    [Pg.166]    [Pg.120]    [Pg.317]    [Pg.1271]    [Pg.569]    [Pg.120]    [Pg.368]    [Pg.155]    [Pg.410]    [Pg.9]    [Pg.108]   


SEARCH



Modified oxides

Modifier oxide

Oxidation modified

© 2024 chempedia.info