Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Other Operating Modes

There are several other operation modes, such as the intermittent contact mode, (Fig. 6c) where the cantilever oscillates and the tip records the repulsive contact with the surface at the lowest point of the oscillation, and the force modulation mode (Fig. 6d) where the tip does not leave the surface at all during the oscillation cycle. [Pg.122]

A microsensor system for simultaneous amperometric determination of H2O2 and 02 consists of two working electrodes, one Pt counterelectrode and one WO3 reference electrode. The working electrodes are GCE covered with HRP immobilized in an elec-trodeposited membrane of polypyrrole the working electrode for 02 has in addition a layer of immobilized superoxide dismutase. Operation with this system is at pH 5.1, setting both working electrodes at —60 mV. Other operating modes are also possible. ... [Pg.653]

However, for illustration, only one side of the interferogram and its spectrum will be shown, usually the function of the positive spatial and spectral variable. In other operating modes of the interferometer, asymmetric interferograms are produced that have a complex Fourier transform. Asymmetric interferograms will not be treated in this work. For a more complete discussion of Fourier transform spectroscopy, the reader should consult Bell (1972), Vanasse and Strong (1958), Vanasse and Sakai (1967), Steel (1967), Mertz (1965), the Aspen International Conference on Fourier Spectroscopy (Vanasse et al., 1971), and the two volumes of Spectrometric Techniques (Vanasse, 1977, 1981). A review of early work, which includes several major contributions of his own, is given by Connes (1969). Another interesting paper on the earlier historical development of Fourier transform spectroscopy is that by Loewenstein (1966). [Pg.303]

The validation life cycle provides several advantages over prior methods for the organization of validation programs. The cohesiveness of an organization s validation efforts when the life-cycle approach is utilized as an operational model is unattainable in other operating modes. [Pg.94]

In mode D, as illustrated in Figure 2d, the EOF velocity is higher than the electrophoretic velocity and the sample components appear in an order reversed with respect to that found in all other operational modes [1]. As seen, they appear at the other end of the capillary in the order of increasing electrophoretic mobilities, with the peak of the neutral tracer being the first. Table 1 shows that in mode D the k e is negative and less than unity. [Pg.8]

Liapis, A. I., Rippin, D. W. T. The simulation of binary adsorption in continuous counter-current operation and a comparison with other operation modes, AIChE/., 1979, 25(3), 455-460. [Pg.427]

Liapis, A.I., and Rippin, D.W.T., Simulation of binary adsorption in continuous countercurrent operation and comparison with other operating modes. AlCliE J., 25(3), 455-460 (1979). [Pg.981]

EOP packages generally do not cover operational modes other than normal power operation. However, it is also necessary to provide EOP guidance for other operational modes, including unit startup and shutdown, and during various shutdown and outage conditions. It has been demonstrated by several shutdown and low power probabilistic safety analysis (PSA) studies that the contribution to overall risk of these plant operational modes is... [Pg.18]

Multimode Scanning Probe Microscopes Many commercial SPMs are capable of multimode operation, They can be used as AFMs in contact, tapping, and noncontact modes and as STMs. Other operational modes, such as lateral force mode, torsional mode, and magnetic force mode may also be possible, depending on the manufacturer and model. [Pg.844]

Cycle characteristics for other operation modes (refuelling once in one or two years) are presented in Table VII-2. ... [Pg.248]

Defects at the interface most likely play an important role in the delamination process. Unfortunately, the defects in self-assembled films are mostly nanoscopic and can be studied only with atomic force microscopy (AFM) and STM, which require very time-consuming preparation and limit the flexibility of the experiments. Other operation modes such as scanning Kelvin probe force microscopy (SKPFM) [73] will play an important role in future work [74]. [Pg.497]


See other pages where Other Operating Modes is mentioned: [Pg.175]    [Pg.653]    [Pg.69]    [Pg.237]    [Pg.244]    [Pg.246]    [Pg.69]    [Pg.307]    [Pg.885]    [Pg.217]    [Pg.1009]    [Pg.65]    [Pg.68]    [Pg.243]    [Pg.245]    [Pg.787]    [Pg.19]    [Pg.638]    [Pg.74]    [Pg.76]   


SEARCH



Operating mode

Operation mode

Operation modes mode

© 2024 chempedia.info