Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Ortho-Clinical Diagnostics

Ortho-Clinical Diagnostics, Vitros Mg Slide, Johnson Johnson Co, Rochester, NY, USA. (http //www.fda.gov/cdrh/pdf2/k023876.pdf). [Pg.311]

Figure 7 Reaction proceedings in the Ortho Clinical Diagnostics lipase slide teiL l 01eyl-L3 di ceiy1glycefol serves as an artificial substrate for lipase. Figure 7 Reaction proceedings in the Ortho Clinical Diagnostics lipase slide teiL l 01eyl-L3 di ceiy1glycefol serves as an artificial substrate for lipase.
DPC = Diagnostics Products Corporation OCD = Ortho-Clinical Diagnostics... [Pg.60]

Figure i I -3 A schematic, exploded view of the multilayer dry film reagent used inVitros analyzers, (Courtesy Ortho-Clinical Diagnostics.)... [Pg.274]

Some systems are designed to sort the specimens into racks for transfer to particular laboratory sections or analyzers as described above. These systems (AI Scientific, Aloka, Olympus, Ortho-Clinical Diagnostics, and Tecan) sort the aliquot and original tubes into racks for manual transport to analyzers or lab sections. In some cases the racks maybe specific for a specific analyzer, eliminating additional handling of tubes. [Pg.289]

Any H2O2 diffusing back into the sample chamber is destroyed by catalase to prevent interference with the analysis. Determinations maybe performed on 25 (xL of plasma, serum, or whole blood. Good precision and correlation with an oxygen consumption rate analyzer have been reported. The Vitros system (Ortho-Clinical Diagnostics, Raritan, NJ) makes use of dry multilayer films for chemical analy-... [Pg.871]

Jonathan B. Crowther (415) Ortho-Clinical Diagnostics, 1001 U.S. Highway 202, Raritan, New Jersey, 08869-0606... [Pg.581]

Recently, we adapted the Ortho Clinical Diagnostics lipase slide test [29], a dry chemistry test system used in clinical biochemistry to measure the lipase activity in human serum for the determination of the lipase activity in pancreatic extracts. The substrate, l-oleyl-2,3-diacetylglycerol, and the ancillary reagents are fixed in a multilayered film (Fig. 7). Upon addition of a lipase solution, the insoluble substrate becomes emulsified. [Pg.198]

Many IS Es based on solid or Kquid membranes and ion-selective FETs possess sufficiently small Kij values (Eq. 1) toward common interferents, and have been developed into commercial benchtop analyzers that allow the measurement of Na+, K+, Ca +, Cl , HC03, and other ions, in instruments that are designed solely for IS E measurements or in combination with other integrated devices (such as amper-ometric sensors and spectrophotometers) to measure other parameters [7]. Applications of these devices to blood gas analysis have been reviewed recently [81]. Companies that produce this instrumentation for clinical chemistry applications include Abbott Diagnostics, AVL, Bayer Diagnostics, Beckman Coulter, Nova Biomedical, Ortho-Clinical Diagnostics, Boehringer-Mannheim/Roche, and Radiometer [82]. Many instruments allow measurements to... [Pg.5611]


See other pages where Ortho-Clinical Diagnostics is mentioned: [Pg.50]    [Pg.285]    [Pg.285]    [Pg.286]    [Pg.287]    [Pg.307]    [Pg.1641]    [Pg.1641]    [Pg.415]    [Pg.50]    [Pg.285]    [Pg.285]    [Pg.286]    [Pg.287]    [Pg.307]    [Pg.1641]    [Pg.1641]    [Pg.415]    [Pg.194]   
See also in sourсe #XX -- [ Pg.287 ]




SEARCH



Clinical diagnostics

© 2024 chempedia.info