Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Operating procedures preparing

The second aspect of quahty documentation is to detail how the work processes referred to in the manual are performed. The QA unit is often the organization responsible for issuing a set of procedures designed to assure conformance to the appropriate standards or to company poHcy. The procedures, often called standard operation procedures (SOP) or quahty operating procedures (QOP), should include such topics as customer complaints, audit protocols, stabihty testing, preparation of COAs, test method vahdation, etc. [Pg.369]

This chapter describes some accidents that occurred because operating procedures were poor. It does not include accidents that occurred because of defects in procedures for preparing equipment for maintenance or vessels for entry. These are discussed in Chapters 1 and 11. [Pg.309]

In the author s experience, field residue trials can be conducted in Latin America under complete compliance with all ERA guidelines and recommendations. More time does need to be spent in planning and preparation to ensure that the personnel involved in the testing have been trained in GLP and that this training, as well as the compliance of equipment, storage and archival sites, standard operating procedures (SOPs), and quality assurance (QA) audits, are properly documented. [Pg.199]

Dining an attempt to prepare an anhydrous 25% solution of peroxyacetic acid in acetic acid by dehydrating a water-containing solution with acetic anhydride, a violent explosion occurred. Mistakes in the operational procedure allowed heated evaporation to begin before the anhydride had been hydrolysed. Acetyl peroxide could have been formed from the anhydride and peroxyacid, and the latter may have detonated and/or catalysed violent hydrolysis of the anhydride [1], A technique for preparing the anhydrous acid in dichloromethane without acetyl peroxide formation has been described [2],... [Pg.321]

All six samples at both sites were prepared the same way. Five separate aliquots from each sample were separately sampled and prepared for testing. Each aliquot was then measured three times. Conditions and standard operating procedures for METHODS A and B were carefully specified for both Labs 1 and 2. [Pg.173]

The methods to be used and a copy of Standard Operating Procedures (SOPs) where accredited, including any sampling and sample preparation protocols, to be supplied to the customer. [Pg.109]

Results Standard operating procedures (SOPs) have been prepared for each method developed. [Pg.106]

Exchange Column Procedure. J. Amer. chem. Soc. 70, 3520 (1948). 125- Tompkins, P. C., L. Wish and J. X. Khym Some Unit Operations for Preparation of Carrier-free Strontium. U. S. Nat. Nuclear Energy Ser., Vol. 9B, Paper 239- New York McGraw-Hill 1951. [Pg.20]

Traditionally, the education that chemists and chemistry laboratory technicians receive in colleges and universities does not prepare them adequately for some important aspects of the real world of work in their chosen field. Today s industrial laboratory analyst is deeply involved with such job issues as quality control, quality assurance, ISO 9000, standard operating procedures, calibration, standard reference materials, statistical control, control charts, proficiency testing, validation, system suitability, chain of custody, good laboratory practices, protocol, and audits. Yet, most of these terms are foreign to the college graduate and the new employee. [Pg.3]

The size of reactor needed for a given duty is found as follows. For plug flow tabulate the rate for various Xp along this adiabatic operating line, prepare the y -rp) versus Xp plot and integrate. For mixed flow simply use the rate at the conditions within the reactor. Figure 9.8 illustrates this procedure. [Pg.223]

The terms defined above are perhaps illustrated by using the example of the simple assay which we have mentioned before. The assay in Box 1.3 is laid out in the style of a SOP. This particular section of the operating procedure describes the assay itself but there would also be other sections in the procedure dealing with safety issues, the preparation and storage of the solutions used for extraction and dilution, the glassware required and a specification of the instrumentation to be used. [Pg.9]

Operating procedure for CIP of the freeze dryer Operating procedure for freeze dryer plant test Operating procedure SIP cycle of freeze dryer Operating procedure for freeze dryer Operating procedure for Truflow integrity tester Operating procedure for SIP cycle of the preparation/mobile tank... [Pg.534]


See other pages where Operating procedures preparing is mentioned: [Pg.101]    [Pg.237]    [Pg.101]    [Pg.237]    [Pg.101]    [Pg.121]    [Pg.2269]    [Pg.1118]    [Pg.234]    [Pg.242]    [Pg.81]    [Pg.160]    [Pg.117]    [Pg.45]    [Pg.353]    [Pg.134]    [Pg.198]    [Pg.515]    [Pg.931]    [Pg.10]    [Pg.532]    [Pg.42]    [Pg.511]    [Pg.318]    [Pg.399]    [Pg.53]    [Pg.63]    [Pg.20]    [Pg.220]    [Pg.222]    [Pg.642]    [Pg.23]    [Pg.57]    [Pg.161]    [Pg.117]    [Pg.595]    [Pg.215]    [Pg.232]    [Pg.385]   
See also in sourсe #XX -- [ Pg.306 ]

See also in sourсe #XX -- [ Pg.306 ]




SEARCH



Operational procedure

Operations Procedures

Preparation procedure

Preparative procedures

Standard operating procedures preparation

© 2024 chempedia.info