Multiple collector inductively coupled plasma mass spectrometry

Multiple-collector inductively coupled plasma mass spectrometry (MC-ICPMS) combines sector-field ICPMS with a multiple collector detector system and has recently emerged as an alternative to TIMS for precise U-Th isotope measurement. The full potential of MC-ICPMS has yet to be realized. Yet despite this, its performance in high precision isotope measurement already challenges and, in some cases, surpasses that ever achieved by TIMS (e.g., Lee and Halliday 1995 Blichert-Toft and Albarede 1997). [Pg.39]

Gussone N, Eisenhauer A, Heuser A, Dietzel M, Bock B, Bohm E, Spero H, Lea D, Buma J, Nagler, TF (2003) Model for kinetic effects on calcium isotope fractionation (6 Ca) in inorganic aragonite and cultured planktonic foraminifera. Geochim Cosmochim Acta 67 1375-1382 Halicz L, Galy A, Belshaw NS, O Nions RK (1999) High precision measurement of calcium isotopes in carbonates and related materials by multiple collector inductively coupled plasma mass spectrometry (MC-ICP-MS). J Anal Atom Spectr 14 1835-1838... [Pg.286]

Rouxel O, Ludden J, Carginan J, Marin L, Fouquet Y (2002) Natural variations of Se isotopic composition determined by hydride generation multiple collector inductively coupled plasma mass spectrometry. Geochim Cosmochim Acta 66(18) 3191-3199... [Pg.316]

In the environment, Mo isotope research began in earnest with the application of multiple-collector inductively coupled plasma mass spectrometry. While much work remains to be done, this early research points to promising applications in paleoceanography, and beyond. [Pg.430]

U-XRF spectrometry synchrotron-based micro-x-ray absorption near-edge stmcture spectroscopy multiple collector inductively coupled plasma mass spectrometry... [Pg.177]

Multiple-Collector Inductively Coupled Plasma Mass Spectrometry... [Pg.291]

Table 1 Comparison of Isotopic Compositions Measured by Multiple-Collector Inductively Coupled Plasma Mass Spectrometry and Those Measured by Thermal Ionization Mass Spectrometry... [Pg.304]

Figure 10 High-precision U isotopic compositions of NIST SRM 960, as measured by thermal ionization mass spectrometry (TIMS) and multiple-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). (From Halliday et al., 1998b.)... Figure 10 High-precision U isotopic compositions of NIST SRM 960, as measured by thermal ionization mass spectrometry (TIMS) and multiple-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). (From Halliday et al., 1998b.)...
Hirata, T. (1996) Lead isotopic analyses of NIST standard reference materials using multiple collector inductively coupled plasma mass spectrometry with a modified external correction method for mass discrimination effect. Analyst 121, 1407-1411. [Pg.324]

Several isotopes (see Isotopes Isotope Labeling) of Cd are known, and 8 are stable (Table 3). For " Cd and " Cd, the nnclear spin is 1/2 and they are used for NMR studies of Cd compounds and in biological fields (see Cadmium Organometallic Chemistry). " Cd is used in the nuclear industry because of its high neutron cross section. Unstable isotopes are prepared from nuclear reactions. Cd stable isotope composition in geological and meteorite samples has been investigated using multiple collector inductively coupled plasma mass spectrometry. ... [Pg.527]

Galy, A., Belshaw, N.S., Halicz, L, and O Nions, R.K (2001) High-precision measurement of magnesium isotopes by multiple-collector inductively coupled plasma mass spectrometry. Int. J. Mass Spectrom., 208, 89—98. [Pg.489]

Zhu, J.M., Johnson, T.M., Clark, S.K., and Zhu, X.K. (2008) High precision measurement of selenium isotopic composition by hydride generation multiple collector inductively coupled plasma mass spectrometry with a Se- Se double spike. Chin. J. Anal. Chem., 36, 1385-1390. [Pg.491]

HallidayA. N., Christensen,J. N., Der-Chuen, L., Hall, C. M., Luo, X., and Rehkamper, M. (2000). Multiple-collector inductively coupled plasma mass spectrometry. Pract. Spectrosc., pp. 291-328. [Pg.220]

Hirata, T. and Yamaguchi, T. (1999) Isotopic analysis of zirconium using enhanced sensitivity-laser-ablation-multiple collector-inductively coupled plasma mass spectrometry. J. Anal. At. Spectrom., 14, 1455-9. [Pg.178]

Walder, A. J. (1997) Advanced isotope ratio mass spectrometry, II Isotope ratio measurement by multiple collector inductively coupled plasma mass spectrometry. In Modem Isotope Ratio Mass Spectrometry (ed. I. T. Platzner), John Wiley Sons, London, pp. 83-108. [Pg.445]


See other pages where Multiple collector inductively coupled plasma mass spectrometry is mentioned: [Pg.578]    [Pg.66]    [Pg.229]    [Pg.244]    [Pg.266]    [Pg.30]    [Pg.292]    [Pg.539]    [Pg.71]    [Pg.309]    [Pg.314]    [Pg.491]    [Pg.81]   


SEARCH



Collector

Coupled Plasma

Coupled spectrometry

Coupling spectrometry

Couplings mass spectrometry

Induction-coupled plasma

Inductive coupled plasma

Inductive coupled plasma mass spectrometry

Inductive coupling

Inductively couple plasma

Inductively couple plasma mass spectrometry

Inductively coupled

Inductively coupled mass spectrometry

Inductively coupled plasma mass

Inductively coupled plasma mass multiple-collector

Inductively coupled plasma mass spectrometry

Inductively mass spectrometry

Mass plasma

Multiple collector inductively coupled

Plasma mass spectrometry

Plasma spectrometry)

© 2024 chempedia.info