Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Mossbauer data

As shown in Fig. 7.6, the Mossbauer data show a reduction in Morin transition temperature with increasing shock severity. At temperatures below the transition, increasing shock severity causes greater retention of the higher temperature, weak ferromagnetic contribution. The measure of weak ferromagnetic (WF) fraction (the high temperature form) is a sensitive indication of shock modification. [Pg.169]

Table 3. Mossbauer data of iron silylene complexes (Fe as standard)... Table 3. Mossbauer data of iron silylene complexes (Fe as standard)...
The Sn Mossbauer data for Sn7S2Brio, Sn4SeBr, and Sn4TeBr, have been measured, and compared with those of the parent halides and chalcogenides. The data are consistent with a random distribution of halide and chalcogenide anions (104). Thus far, the reflection spectra of a few tin(IV) compounds assumed to be semiconductors have... [Pg.395]

In summary, the Mossbauer data presented by Fee et al. (5) gave the first conclusive evidence that Rieske clusters contain noncysteine ligands bound to the Fe" site of a localized mixed valence cluster. In addition, strong similarities with [2Fe-2S] clusters in bacterial dioxy-... [Pg.118]

Mossbauer data also seemed to agree with the proposal of a [6Fe-6S] cluster ill). About two-thirds of the Fe intensity of the reduced protein (i.e., four out of the proposed total of six) had isomer shift... [Pg.226]

MIMOS II has three temperature sensors one on the electronics board and two on the SH. One temperature sensor in the SH is mounted near the internal reference absorber, and the measured temperature is associated with the reference absorber and the internal volume of the SH. The other sensor is mounted outside the SH at the contact ring assembly. It gives the approximate analysis temperature for the sample on the Martian surface. This temperature is used to route the Mossbauer data to the different temperature intervals (maximum of 13, with the temperature width software selectable) assigned in memory areas. Shown in Fig. 3.21 are the data of the three temperature sensors taken on Mars (rover Opportunity at Meridiani Planum) in January 2004 between 12 10 PM on Sol 10 (10 Martian days after landing) and 11 30 AM on Sol 11. The temperature of the electronics board inside the rover is much higher than the temperatures inside the SH and the contact plate sensor, which are nearly identical and at ambient Martian temperature. [Pg.62]

To minimize the risk of data loss because of power failure or other reasons, the Mossbauer data are copied to a nonvolatile EEPROM (Electrically Erasable Programmable Read-Only Memory) every 9 minutes (software selectable). As the size of the EEPROM is smaller than the SRAM, the EEPROM can accumulate only up to ten Mossbauer spectra as a subset of the data from the SRAM. These spectra are obtained from the SRAM according to a pre-defined summation strategy. [Pg.66]

In addition to the Mossbauer data, SDDs allow the simultaneous acquisition of the XRF spectrum, thus providing data on the sample s elemental composition. A new control- and readout-electronics for MIMOS llA allows spectra acquisition at highest possible count rates available at a total detector area of 360 mm. ... [Pg.67]

The isomer shift is considered the key parameter for the assignment of oxidation states from Mossbauer data. The early studies, following the first observation of an isomer shift for Fe203 [7], revealed a general correlation with the (formal) oxidation state of iron. However, isomer shifts have also been found to depend on the spin state of the Mossbauer atom, the number of ligands, the cr-donor and the... [Pg.83]

About 20 HTe superconducting compounds and copper oxidic systems Correlations of the Cu NQR/NMR data with the Cu( Zn) emission Mossbauer data for HTSC lattices as a tool for the determination of atomic charges... [Pg.267]

In an account on the reduction of Mossbauer data, Foyt et al. [142] have described a general analysis of quadrupole split Ru spectra. [Pg.281]

Supported (alumina, silica) Ru catalysts The Mossbauer data show that RuCl3 (l-3)H20 reacts chemically when supported onto alumina, but does not when impregnated on a silica support. The study further shows that a supported ruthenium catalyst converts quantitatively into RUO2 upon calcination, and that the reduction of a supported ruthenium catalyst converts all of the ruthenium into the metallic state... [Pg.284]

Pt-Ru anodes for methanol electrooxidation The catalytically most active samples are highly dispersed and contain, as indicated by the Mossbauer data, a mixture of two Ru(IV) species... [Pg.284]

Colloids embedded in a silica sol-gel matrix were prepared by using fully alloyed Pd-Au particles. The Mossbauer data have yielded evidence that alloying Pd with Au in bimetallic colloids leads to enhanced catalytic hydrogenation and also to improved selectivity [426]. [Pg.364]

The chemistry of iron(IV) in solid-state materials and minerals is restricted to that of oxides, since other systems such as iron(IV)-halides are not stable [186]. Iron(lV) oxides are easy to handle because they are usually stable in air, but they often have a substoichiometric composition, with oxygen vacancies contributing to varying degrees. Moreover, the samples may contain different amounts of iron(lll) in addition to the intended iron(IV) oxide, a complication which may obscure the Mossbauer data [185]. Even iron(V) was found in iron(IV) oxides due to temperature-dependent charge disproportionation [188, 189]. [Pg.430]

Hydroxylase in the mixed-valent Fe(II)Fe(III) oxidation state (Hmv) is readily accessible by one-electron reduction of the dinuclear center. Mossbauer data indicate the presence of one Fe(III) and one Fe(II) (39). Hmv has a rhombic EPR signal with gav = 1.83 (27, 37) and J -30 cm1 (38,39), properties characteristic of other mixed-valent nonheme carboxylate-bridged diiron centers such as that in semimet hemerythrin (J = -15 cm-1) (32). ENDOR spectroscopic studies of Hmv... [Pg.270]

Table 1. Mossbauer data obtained from spectra of ZSM-22 (Si/Fe = 27) (IS isomer shift, mm/s, QS quadrupole splitting, mm/s, RI relative intensity, %). Table 1. Mossbauer data obtained from spectra of ZSM-22 (Si/Fe = 27) (IS isomer shift, mm/s, QS quadrupole splitting, mm/s, RI relative intensity, %).

See other pages where Mossbauer data is mentioned: [Pg.170]    [Pg.2]    [Pg.36]    [Pg.63]    [Pg.65]    [Pg.68]    [Pg.232]    [Pg.245]    [Pg.362]    [Pg.364]    [Pg.375]    [Pg.379]    [Pg.379]    [Pg.381]    [Pg.382]    [Pg.384]    [Pg.387]    [Pg.387]    [Pg.391]    [Pg.407]    [Pg.244]    [Pg.234]    [Pg.125]    [Pg.276]    [Pg.396]    [Pg.407]    [Pg.419]    [Pg.450]    [Pg.463]    [Pg.279]    [Pg.914]    [Pg.215]    [Pg.114]    [Pg.489]   
See also in sourсe #XX -- [ Pg.478 ]




SEARCH



DCC Model Lattice Parameter and Lns-Mossbauer Data Analysis

High-pressure Mossbauer data

Lns-Mossbauer and lattice parameter data of DF oxides

Lns-Mossbauer data analysis

Mossbauer data complex

Review of existing Mossbauer data

Table of nuclear data for Mossbauer transitions

Zeolite Mossbauer data

© 2024 chempedia.info