Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Monitors conductivity

Are personnel and air monitoring conducted for chemicals with TLVs ... [Pg.163]

The determination of these compounds in biological fluids is crucial for several reasons such as investigating overdosing (toxicological monitoring), conducting pharmacokinetic and bioavailability studies, and measuring compliance. [Pg.31]

The proposed regulations went beyond these basic requirements for a valid study by requiring each study to have a study director who would have ultimate responsibility for implementation of the protocol and conduct of the study [ 3e/31(a)], and each testing facility to have a quality assurance unit to monitor conduct of studies. The concept of a quality assurance unit to monitor study conduct was a new one to most laboratories but a familiar one in manufacturing facilities operating under various GMP regulations. [Pg.18]

The following characteristics must be monitored conductivity, C°T at the return of the loop, and flow at the return of the loop. A sampling valve must be located near each main point of use. [Pg.74]

A decade ago, the state of biodiversity and productivity of the Blak Sea ecosystem led to suggestions that the process of degradation of the Black Sea is catastrophic or even irreversible. However, environmental monitoring, conducted over the past 10 years, reflects continued improvements in the state of the Black Sea ecosystem. These improvements appear to be the direct or indirect results of reduced economic activity in the region, to a certain degree of protective measures taken by governments and international organizations. [Pg.451]

Conductometry — is a nonselective analytic method based on monitoring conductivity of a physical mixture, a solution or a homogeneous solid material. This... [Pg.111]

Although cirrhosis was reported in both cases, neither worker had a history of excessive alcohol intake. These men worked with tetryl for 1-4 years and were exposed primarily by inhalation of tetryl-laden dust. Limited air monitoring, conducted in 1942, reported concentrations of tetryl ranging... [Pg.29]

Thus, despite many advantages, the monitoring conducted for piuposes of identifying and estimating the radiation situation and ensiuing safety of the nearby population had a number of important shortcomings, such as ... [Pg.161]

Fat oxidative stability is measured by the active oxygen method (AOM, AOCS Method Cd 12-57). Oil or fat is held at 97.8°C while air is bubbled through it. The time required to develop a peroxide concentration of 100 meq/kg is the AOM stability of the sample. A closely related method, the oil stability index (OSI, AOCS Method Cd 12b-92), also bubbles air through hot oil. One of the breakdown products is formic acid, which is trapped in a water cell. The machine continuously monitors conductivity of the water, and records the time when it rises sharply. Rancimat times obtained at 110°C are 40-45% of the AOM times, so an OSI stability of 4 h is equal to an AOM stabihty of 10 h. [Pg.2200]

American Society of Health-System Pharmacists Statement on the Pharmacist s Role in Clinical Pharmacokinetic Monitoring This is a position statement that provides background information and lists responsibilities that should be a part of clinical pharmacokinetics services or monitoring conducted by all pharmacists. In addition, a list of responsibilities that should be assumed by pharmacists with specialized education, training, or experience in pharmacokinetics is provided. ... [Pg.166]

The automated liquid-liquid extraction unit ALLEXis (Metder Toledo Myriad) uses a flow cell to monitor conductivity and thereby detect the phase boundary. The system is able to divert the upper and lower phases into individual vessels. The total volume depends on the size of the settling chamber and is of the order of 2 to 90 mL (Fig. 10). [Pg.551]

CFR1910.1200 (h)(3)(i) 29CFR1910.1450(f)(4)(i)(A) 4.1.4.1 Methods and observations that may be used to detect the presence or release of a hazardous chemical in the work area (such as monitoring conducted by the employer, continuous monitoring devices, visual appearance or odor of hazardous chemicals when being released, etc.) ... [Pg.297]

At present, four companies provide specialized impedance measurement instrumentation for chnical microbiology or food hygiene applications. BioMirieux manufactures the Bactometer, which can monitor conductance, capacitance, or impedance in up to two temperature-controlled incubators, each containing 256 samples. Malthus Instruments produces... [Pg.5627]

Conductivity Conductivity measurement has historically been the most important method of condensate quality monitoring. Conductivity meters are relatively inexpensive, are quite reliable, and require a minimum of maintenance. They will detect most common inorganics except silica. [Pg.152]

In situ conductimetry is a convenient tool for studying the influence of different conditions on the preparation of conductive polymers. Conductivity is perhaps the best single parameter that describes the quality of a CP. In addition, the dopingundoping processes can be studied by monitoring conductance as potential is being scanned. Unfortunately, no commercial instrument directly applicable for in situ conductimetry is yet available, although it is possible to construct one from a commercial bipotentiostat and appropriate microelectrodes. The double-band platinum electrode can be constructed relatively easily without any special tools [7] (Fig. 12).. [Pg.194]

Historical monitoring data means data from chromium (VI) monitoring conducted prior to May 30,2006, obtained during work operations conducted under workplace conditions closely resembling the processes, types of material, control methods, work practices, and environmental conditions in the employer s current operations. [Pg.963]

The routine monitoring conducted in commercial vineyards in Qiampagne, France, revealed the presence of resistance to benzimidazoles, dicarboximides and anilinopyrimidines in grapevine grey mold (15), Ifowever, the limitation in the use of these three families of botryticides prevents the build-up of resistant populations. [Pg.284]


See other pages where Monitors conductivity is mentioned: [Pg.181]    [Pg.4]    [Pg.400]    [Pg.63]    [Pg.233]    [Pg.27]    [Pg.3]    [Pg.280]    [Pg.399]    [Pg.489]    [Pg.345]    [Pg.41]    [Pg.80]    [Pg.463]    [Pg.345]    [Pg.83]    [Pg.628]    [Pg.260]    [Pg.131]    [Pg.871]    [Pg.967]    [Pg.151]   
See also in sourсe #XX -- [ Pg.271 ]




SEARCH



Conductance monitors

Conductance monitors

Conductivity monitoring

Monitoring methods Conductivity

© 2024 chempedia.info