Spectrum , mobility

Both the 2, helix and the 3, helix are represented in the low mobility spectrum of polymers close to cellulose (figure 4), although there was some interference from xyloglucan signals. [Pg.567]

If cellulose exists in the cell wall as a network within a pectic matrix, the pectin that is within about 2nm of the cellulose network maybe on or near exposed surfaces of cellulose microfibrils. Both the gel and the eggbox pectins are represented in this low mobility spectrum. [Pg.567]

An ion mobility spectrometer offers to prospective users an attractive detector for a GC, from the perspective of detection limits and specificity. A mobility spectrometer, even with low resolution, allows interrogation of compound identities and imparts better specificity than the electron-capture detector. When gaseous analytes are delivered individually to IMS, the mobility spectrum contains information for identification, provided that operating conditions are kept constant for the unknown and reference spectra. The connection of a GC column to an ion mobility spectrometer is... [Pg.470]

GC-IMS-MS instruments are ideally suited for laboratory studies, as a complex mixture can be separated ionisation in relatively clean systems can take place and the identity of the ions can be studied and verified by mass spectrometry [315]. However, the cost of such systems is quite prohibitive, and their complexity confines their utilisation to the laboratory. In GC-IMS-MS, the gas chromatograph is used to preseparate the components of the sample, with the IMS used as its detector. The ions that constitute the mobility spectrum are then further characterised by MS. [Pg.471]

Bricard, J., F. Billard, D. Blanc, M. Cabane, and J. Fontan, Detailed Structure of the Mobility Spectrum of the Small Radioactive Ions in the Air, Compte Rendus de l Academie des Sciences de Paris 263 761-764, Series B, (1966). [Pg.366]

Since the mobility analyzer collects only charged particles, the size distribution derived from the mobility spectrum is only for the charged particles. There are some correlations among these three different methods at both high and low S02 concentrations. [Pg.373]

The ion mobility spectrum in Figure 22-16b is a graph of detector response versus electrophoretic terms, see problem 26-46. drift time for several explosives. Peak area is proportional to the number of ions. Peaks are... [Pg.487]

Measurements of the air mobility spectrum seem to add considerable information toward an understanding of aerosol formation and growth at sizes below a few nanometers. Hence, to characterize nucleation mechanisms more precisely, such data should be included in experimental designs. Lagrangian aerosol sampling techniques would also be favored, since this approach can yield data on microphysical evolution without the complicating effects of a changing air mass. Further laboratory studies should be undertaken to quantify the thermodynamic data that define ion properties under tropospheric conditions, at ion sizes and compositions relevant to aerosol nucleation. The sparseness of such data imposes a limitation on our ability to quantify ion-based nucleation mechanisms [19,33],... [Pg.134]

HOrrak, U., H. Iher, A. Luts and H. Tammet, Mobility spectrum of air ions at Tahkuse Observatory, J. [Pg.137]

Noppel, M., Evolution of mobility spectrum of charged nanometer particles in case of vapour nucleation and condensation, J. Aerosol Sci 26, S345-346, 1995. [Pg.138]

Fig. 2. Schematic representation of a mobility spectrometer. Ions created in the ion source are separated in the drift region based on their mobility. The ion swarms reach the detector where their drift times are recorded and plotted in the form of a mobility spectrum (Originally published in the article of Buryakov et al. [9]). Fig. 2. Schematic representation of a mobility spectrometer. Ions created in the ion source are separated in the drift region based on their mobility. The ion swarms reach the detector where their drift times are recorded and plotted in the form of a mobility spectrum (Originally published in the article of Buryakov et al. [9]).
When an ion swarm is injected into the drift region of the drift tube, spatial resolution of ions of differing mobility can be separated as differences in drift velocity as the ions move toward the detector, here at virtual ground. Separate packets or swarms of ions develop with the separation as shown in Fig. 2, where three ion swarms have been resolved in time and space. As ions collide with the detector, commonly a simple metal disc or Faraday plate, neutralization of ions is accompanied by electron flow in the detector plate this is amplified and shown in the inset of Fig. 2. Thisplot of detector response(current or voltage) versus time (in ms) is called a mobility spectrum and is the... [Pg.64]

Fig. 4. a Electrospray mass spectrum of a 100 mmol l-1 solution of L-serine extensive clustering of serine units is observed for charge states z=l, 2, and 3. b Ion mobility spectrum of ions with m/z=841 showing the three features assigned as protonated octamer, doubly protonated 16-mer, and triply protonated 24-mer... [Pg.218]

The 80 K ion mobility spectrum, shown in the right panel of Fig. 8, exhibits two distinct features, which are readily assigned to the two families of closed and open structures [60]. This means that interconversion between the two families of structures is frozen out at 80 K, but is rapid at 300 K. Data taken between 110 and 190 K show that the two peaks present at low temperature melt into one at higher temperatures. Analysis analogous to the previous examples yields an activation barrier for the open-to-closed conversion of 1.6 kcal mol-1. The open-to-closed reaction turns on more rapidly than the reverse reaction, and the closed form is found to be 0.5 kcal mol-1 more stable than the open form [60]. [Pg.221]

The original Acoustosizer used a single frequency whereas a later development has a range of 13 frequencies between 0.3 and 13 MHz. This allows the measurement of the dynamic mobility spectrum and the determination of the zeta potential and particle size. In order to invert the mobility spectrum into a size distribution a log-normal distribution of particle size is assumed. A comparison with photon correlation spectroscopy for determining particle size and laser Doppler anemometry for particle charge eonfirmed the results using ACS [266]. These and additional sedimentation measurements confirmed that changes in particle size and zeta potential due to dilution effects are likely to occur in aqueous and non-stabilized systems. [Pg.584]

Fig. 9.11 Effect on the antibiotic on the peak height in an ion mobility spectrum. Fig. 9.11 Effect on the antibiotic on the peak height in an ion mobility spectrum.
Fig. 9.12 Decrease of the signal (peak area) of the specific peak considered in the ion mobility spectrum of a patient suffering angina lateralis during drug delivery (amoxicillin) for 3 days. Fig. 9.12 Decrease of the signal (peak area) of the specific peak considered in the ion mobility spectrum of a patient suffering angina lateralis during drug delivery (amoxicillin) for 3 days.
If such a process is fast on the n.m.r. time scale, each proton will resonate at a T-value which represents the average of the chemical shifts at each of its environments. This averaged spectrum we will refer to as a mobile spectrum 66). The spectrum may be a simple average, if the... [Pg.31]


See other pages where Spectrum , mobility is mentioned: [Pg.361]    [Pg.171]    [Pg.172]    [Pg.181]    [Pg.181]    [Pg.187]    [Pg.189]    [Pg.242]    [Pg.487]    [Pg.129]    [Pg.129]    [Pg.131]    [Pg.138]    [Pg.70]    [Pg.77]    [Pg.80]    [Pg.81]    [Pg.218]    [Pg.218]    [Pg.220]    [Pg.138]    [Pg.1346]    [Pg.32]    [Pg.34]    [Pg.35]    [Pg.35]    [Pg.38]    [Pg.38]    [Pg.38]    [Pg.38]    [Pg.39]    [Pg.40]   
See also in sourсe #XX -- [ Pg.64 , Pg.70 , Pg.80 , Pg.81 ]

See also in sourсe #XX -- [ Pg.387 ]




SEARCH



Deuterium NMR Spectra of Chain Mobility in Polyethylene

Differential mobility spectrum

Ion mobility spectra

Spectra and mobility of self-trapped (ST) excitons

The Ion Mobility Spectrum

© 2024 chempedia.info