Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Method resonance mass spectrometry

Present day techniques for structure determination in carbohydrate chemistry are sub stantially the same as those for any other type of compound The full range of modern instrumental methods including mass spectrometry and infrared and nuclear magnetic resonance spectroscopy is brought to bear on the problem If the unknown substance is crystalline X ray diffraction can provide precise structural information that m the best cases IS equivalent to taking a three dimensional photograph of the molecule... [Pg.1052]

Fourier-transform ion cyclotron resonance mass spectrometry (FT-ICR) is a very high-resolution mass spectral method (105 to 106, with mass accuracy better than 1 ppm), which allows separation and empirical formula measurement of potentially thousands of metabolites without chromatic separation. [Pg.190]

The idea that free radicals occur in many chemical reactions is as old as the study of the mechanisms of these reactions. However, direct physical evidence for the existence of free radicals and for their presence in certain reactions is comparatively recent. Such evidence has been obtained in recent years by the methods of mass spectrometry, optical spectroscopy, and electron spin resonance spectrometry. The optical method of detecting free radicals has the advantage that it simultaneously supplies information about the structure of the radical. Indeed, in many instances the nature of the free radical has been identified by the structure of the spectrum without any assumptions about the mechanism of the reaction in which it appears.1... [Pg.2]

The field of ion-molecule reactions has profited immensely from the introduction of new techniques in mass spectrometry such as Fourier Transform Ion-Cyclotron Resonance Mass Spectrometry (FT-ICR) and Selected-Ion Flow Tube methods (SIFT). Several accounts of the progress in the field of ion-molecule reactions involving silicon-containing molecules have been published. For review articles the reader is referred elsewhere1,3,4,40-51 A detailed compilation of the kinetic data for bimolecular ion-molecule reactions of positive silicon ions has been published by Anicich52. [Pg.1109]

The negative ion mass spectra of 21 was studied by an electron im-pact/Fourier transform ion cyclotron resonance mass spectrometry method (95MI13). [Pg.157]

Nedelkov D, Nelson RW (2006) Surface plasmon resonance mass spectrometry for protein analysis. In Nedelkov DN, Nelson RW (eds) Methods in molecular biology new and emerging proteomic techniques. Humana Press, Totowa, NJ, pp 131-139... [Pg.154]

The same concept in proteomics studies has technological implications, e.g., which method, sample preparation protocols, and instrumentation will be used. Again, top-down analysis will be based on isolation, analysis, and characterization of an intact protein to reveal its function. Fourier transformed ion cyclotron resonance mass spectrometry (FT-ICR) (Marshall et al., 1998) facilitates such approach in protein identification as a result of random fragmentation of an intact molecule. In contrary, bottom-up approach is based on up-front fragmentation of the protein in question using various proteolytic enzymes with known specificity (Chalmers et al., 2005 Millea et al., 2006). In these experiments, trypsin is most commonly used. An important question that remains is whether more... [Pg.726]

It is perhaps a little surprising that improved analytical methods (e.g., high-performance liquid chromatography, proton resonance mass spectrometry) have not led to a reexamination of catecholamines as markers of stress and adrenal medullary function. [Pg.231]

With regard to instrumentation design, WT was applied to process real-time signals from the mass spectrometer. Shew [51] invented a new procedure for determining the relative ion abundances in ion cyclotron resonance mass spectrometry, by utilizing WT to isolate the intensity of a particular ion frequency as a function of position or time within the transient ion cyclotron resonance signal. In 1995, this new method was patented in the U.S. Shew explained that the WT intensity corresponding to the frequency of each ion species as a function of time can be fitted by an exponential decay curve. By... [Pg.254]

Section. 1 treats molecular s K ctroscopy in nine chapters that describe absorption, emission, luminescence. infrared, Raman, nuclear magnetic resonance. mass spectrometry, and surface analytical methods. [Pg.1052]

Numerous experimental studies have been pubUshed on Au+-ligand compounds Wilkins and coworkers reported lower bounds for bond energies for a number ol complexes, derived from gas-phase reactions of Au+ with a series of organic compounds. Schrikler and coworkers applied a similar technique to determine and characterize the Au—F bond energy. A more detailed work deaUng with ligand exchange reactions used ion cyclotron resonance mass spectrometry as an analytical method to provide... [Pg.3]

The study of organic polymers by mass spectrometry has been an active field of research in recent years. Both time-of-flight (TOP) and Fourier transform ion cyclotron resonance mass spectrometry (FTMS) have been used in combination with a variety of ionization methods. These include secondary ion... [Pg.531]


See other pages where Method resonance mass spectrometry is mentioned: [Pg.352]    [Pg.356]    [Pg.58]    [Pg.94]    [Pg.81]    [Pg.489]    [Pg.191]    [Pg.2]    [Pg.154]    [Pg.125]    [Pg.4]    [Pg.326]    [Pg.340]    [Pg.596]    [Pg.2545]    [Pg.171]    [Pg.367]    [Pg.122]    [Pg.390]    [Pg.415]    [Pg.299]    [Pg.79]    [Pg.35]    [Pg.2]    [Pg.145]    [Pg.711]    [Pg.51]    [Pg.377]    [Pg.216]    [Pg.92]    [Pg.330]    [Pg.556]    [Pg.569]   
See also in sourсe #XX -- [ Pg.205 ]




SEARCH



Resonance methods

© 2024 chempedia.info