Membrane electrode assembly stream

FIGURE 8.4 Inlet partial pressures of O2 and H2 in the fuel cell feed streams as a function of inlet relativity humidity at 120°C and l.Oatm backpressure. Nation - 12-membrane-based membrane electrode assembly (MEA) with an active area of 4.4 cm [14]. (For color version of this figure, the reader is referred to the online version of this book.)... [Pg.216]

An actual breakthrough is to design both the microstructure (grain size, porosity,...) of the different system materials (support-membrane-catalyst) and the reactor architecture in order to obtain improved permeation properties and stability during the time on stream [19]. Considering all the parameters, a special consideration was given in this paper to the stack of the different materials at different length scale, from the microscopic-scale (microstructure) to the assembly of materials on the whole reactor thickness (architecture). An example of the architecture/microstructure concept was used in the Multi Electrode Assembly (MEA) approach. [Pg.96]

The ED stack is the unit holding together anionic and cationic membranes assembled in parallel as in a filter press between two electrode-end blocks in such a manner that the stream undergoing ion depletion (i.e., the diluate or diluting stream) is kept separated from the other solution (concentrate or concentrating stream) undergoing ion enrichment. Figure 4 shows an exploded view of it. [Pg.280]

The potentiometric technique for FIA monitoring has also been achieved by using ion-selective electrodes (ISEs - see subsection 2.1.1) assembled in a tubular reservoir (with the working electrode positioned at different points in the system). The use of a series of cascading ion-selective electrodes allows the simultaneous determination of various species [342]. To minimize the thickness of the static layer on the electrode surface and achieve an optimum wash-out effect preventing changes at the sensor membrane it is customary to use cascade-type cells in which a small portion of the carrier electrolyte stream is pumped tangentially to the electrode surface [343]. [Pg.431]

An automated system for potentiometric determination of free and total cyanide in wastewaters is by employing a homogeneous membrane tubular ion-selective electrode [38]. After the electrode is assembled, it is connected to a system composed of 3 three-way solenoid valves, sample line, carrier line, acid stream, and gas diffusion chamber. A turbo pascal computer program performs all the steps involved in data acquisition and processing. The proposed analytical procedure offers operational simplicity, since detection is performed by a cyanide ion-selective tubular electrode, and is fast and easy to assemble. [Pg.260]


See other pages where Membrane electrode assembly stream is mentioned: [Pg.381]    [Pg.331]    [Pg.759]    [Pg.17]    [Pg.54]    [Pg.144]    [Pg.34]    [Pg.94]    [Pg.435]    [Pg.360]    [Pg.242]    [Pg.18]    [Pg.323]    [Pg.238]    [Pg.437]    [Pg.488]    [Pg.287]    [Pg.1283]    [Pg.186]    [Pg.764]    [Pg.287]   
See also in sourсe #XX -- [ Pg.157 ]