Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Operator median

Erode applied to a mask peels off a layer from every white island in the mask. Dilate does (almost) the inverse if erode has not managed to delete a white island completely, it is almost restored. The median operator reduces noise in the image without broadening the peaks. The operator is frequently addressed median filter . [Pg.50]

FMHfiltering. A FIR-Median Hybrid Filter (FMH) is a median filter which has a preprocessed input from M linear FIR filters [3, 21]. Thus, the FMH filter output is the median of only M values, which are the outputs of M FIR filters applied to the original data. For an FMH filter of length 21 + 1 with three FIR substructures (M = 3), the data are split into three parts on which the FIR filters are applied. Then, the median operator is applied on the outputs of all FIR filters to obtain the output of the FMH filter. For this particular example, the three FIR filters used are ... [Pg.129]

TAi/2and Tbi/2 median operator response times to take the two actions separately. [Pg.269]

We have implemented all segmentation techniques described above, in an interactive software. The operator can chose and adapt the appropriate segmentation technique with the desired parameters. Some geometrical features can be extracted using a contour following such as length, width, surface, form, median axes of the selected defect. The selection is easy and can be done interactively using the mouse. [Pg.529]

Rossiter (1986) demonstrated the procedure for the production process of crystalline common salt from brine. It was found that the optimal median size is determined by the entrainment limit in the crystallizer. The crystallizer had to be operated at maximum allowable temperature and the slurry density measured for quality constraints. It was also suggested that cost discontinuities should be imposed based on temperatures of the available heat sources, possible materials of construction and other intrinsic properties of the system. [Pg.272]

The component failure rate data used as input to the fault tree model came from four basic sources plant records from Peach Bottom (a plant of similar design to Limerick), actual nuclear plant operating experience data as reported in LERs (to produce demand failure rates evaluated for pumps, diesels, and valves), General Electric BWR operating experience data on a wide variety of components (e.g., safety relief SRV valves, level sensors containment pressure sensors), and WASH-1400 assessed median values. [Pg.120]

Each of the PLgel individual pore sizes is produced hy suspension polymerization, which yields a fairly diverse range of particle sizes. For optimum performance in a chromatographic column the particle size distribution of the beads should be narrow this is achieved by air classification after the cross-linked beads have been washed and dried thoroughly. Similarly, for consistent column performance, the particle size distribution is critical and is another quality control aspect where both the median particle size and the width of the distribution are specified. The efficiency of the packed column is extremely sensitive to the median particle size, as predicted by the van Deemter equation (4), whereas the width of the particle size distribution can affect column operating pressure and packed bed stability. [Pg.352]

Select a median value of Fj = 17, because freedom to operate above and below the design value is preferred in this case. [Pg.198]

The pressure drop of these trays is usually quite low. They can be operated at an effective bubbling condition wnth acceptable efficiencies and low pressure drops. For more efficient operation the clear liquid height on the tray appears to be. similar to the sieve tray, i.e., 1.5-2-in. minimum. This is peculiar to each system, and some operate at 1 in. with as good an efficiency as when a 2-in. is used. When data is not available, 2 in. is recommended as a median design point. [Pg.203]

The Center for Disease Control and Prevention conducted a randomized epidemiological study on patients who had received morphine nerve paste post-operatively for pain management purposes. Ninety-four percent of the patients used in the cohort presented themselves with surgical-site comphcations such as edema and inflammation 24 days (median) post-operation. Upon culturing of the wounds, 64% tested positive for bacterial infection. It is important to note that aU of the patients were found to have residual morphine paste on board indicative of a chronic morphine state (Sacerdote et al. 2000). [Pg.344]

Prior to conducting the DOE (design of experiments) described in Table 3, it was established that no reaction took place in the absence of a catalyst and that the reactions were conducted in the region where chemical kinetics controlled the reaction rate. The results indicated that operating the reactor at 1000 rpm was sufficient to minimize the external mass-transfer limitations. Pore diffusion limitations were expected to be minimal as the median catalyst particle size is <25 pm. Further, experiments conducted under identical conditions to ensure repeatability and reproducibility in the two reactors yielded results that were within 5%. [Pg.197]

The aerodynamic size distributions of Pb-214, Pb-212, Pb-210, Be-7, P-32, S-35-SoJ , and stable SO4 were measured using cascade impactors. Pb-212 and Pb-214, measured by alpha spectroscopy, were largely associated with aerosols small than 0.52 11m. Based on over 46 low-pressure impactor measurements, the mean activity median aerodynamic diameter (AMAD) of Pb-212 was found to be 0.13 11m, while for Pb-214 the AMAD was larger—0.16 lim. The slightly larger size of Pb-214, confirmed with operationally different impactors, was attributed to a-recoil-driven redistribution of Pb-214 following decay of aerosol-associated Po-218. A recoil model was presented that explained this redistribution. Low-pressure impactor measurements indicated that the mass median aerodynamic diameter of SoJ ... [Pg.398]

Fig. 3.35 Median of the resistances belonging to the 38 sensor segments of the gradient micro-array during a meeting of 18 people in a room of 258 m3 without ventilation and with the windows closed for most of the time. The height of the ceiling is 2.80 m. The KAMINA was operated at the back of the room at a height of 1.0 m above the floor. Soon after... Fig. 3.35 Median of the resistances belonging to the 38 sensor segments of the gradient micro-array during a meeting of 18 people in a room of 258 m3 without ventilation and with the windows closed for most of the time. The height of the ceiling is 2.80 m. The KAMINA was operated at the back of the room at a height of 1.0 m above the floor. Soon after...
Depending on operation conditions and metal properties, the shapes of the atomized particles may be spheroidal, flaky, acicular, or irregular, but spherical shape is predominant. The spheroidal particles are coarse. For example, roller-atomized Sn particles exhibited a mass median diameter of 220 to 680 pm. The large particle sizes and highly irregular particle shapes suggested that the disintegration process may be arrested either by the premature solidification or by the formation of a thick, viscous oxide layer on the liquid surface. The particle size distributions were found to closely follow a log-normal pattern even for non-uniform particle shapes. [Pg.105]


See other pages where Operator median is mentioned: [Pg.147]    [Pg.84]    [Pg.147]    [Pg.84]    [Pg.23]    [Pg.1429]    [Pg.94]    [Pg.460]    [Pg.275]    [Pg.124]    [Pg.322]    [Pg.330]    [Pg.762]    [Pg.487]    [Pg.922]    [Pg.29]    [Pg.35]    [Pg.20]    [Pg.20]    [Pg.1021]    [Pg.411]    [Pg.49]    [Pg.9]    [Pg.14]    [Pg.382]    [Pg.51]    [Pg.41]    [Pg.58]    [Pg.1280]    [Pg.86]    [Pg.100]    [Pg.102]    [Pg.107]   
See also in sourсe #XX -- [ Pg.32 , Pg.70 ]