Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Maximum operating junction

The device data sheets provide information regarding the following parameters case options, see Fig. 10.35 for case types maximum operating junction temperature T/(niax) (°C) thermal resistance junction to ambient (no heat sink) 9ja, and thermal resistance junction to case 9jc-... [Pg.1041]

In power compensated DSC the small size of the individual sample and reference holders makes for rapid response. The temperature sensors are platinum (Pt) resistive elements. The individual furnaces are made of Pt/Rh alloy. It is important that the thermal characteristics of the sample and reference assemblies be matched precisely. The maximum operating temperature is limited to about 750 °C. High temperature DSC measurements (750-1600°C) are made by heat flux instruments using thermocouples of Pt and Pt/Rh alloys. The thermocouples often incorporate a plate to support the crucible. The use of precious metal thermocouples is at the expense of a small signal strength. Both chromel/alumel and chromel/constantan are used in heat flux DSC equipment for measurements at temperatures to about 750 °C. Multiple thermocouple assemblies offer the possibility of an increased sensitivity - recently a 20-junction Au/Au-Pd thermocouple assembly has been developed. Thermocouples of W and W/Re are used in DTA equipment for measurements above 1600°C. The operating temperature is the predominant feature which determines the design and the materials used in the con-... [Pg.69]

Exception No. 1 Equipment of the nonheat-producing type, such as junction boxes, conduit, and fittings, and equipment of the heat-producing type having a maximum temperature not more than 100°C (212°E) shall not be required to have a marked operating temperature or temperature range. [Pg.640]

The importance of controlling the operating temperatures of single-crystal and polycrystalline n-CdSe/polysulfide/CoS liquid junction cells to obtain the maximum possible photoconversion has been emphasized [55], In fact, a dramatic effect of temperature was established on the power output of the cells, particularly those based on thin film electrodes. [Pg.220]

In other words, if the mixing junction is moved from the middle of the operation to the beginning of the operation, there is a constant flowrate throughout the operation corresponding with the maximum inlet temperature, after mixing. [Pg.520]


See other pages where Maximum operating junction is mentioned: [Pg.187]    [Pg.187]    [Pg.354]    [Pg.269]    [Pg.354]    [Pg.524]    [Pg.385]    [Pg.299]    [Pg.280]    [Pg.193]    [Pg.237]    [Pg.209]    [Pg.232]    [Pg.268]    [Pg.360]    [Pg.193]    [Pg.94]    [Pg.99]    [Pg.100]    [Pg.662]    [Pg.193]    [Pg.193]    [Pg.473]    [Pg.531]    [Pg.439]    [Pg.582]    [Pg.560]    [Pg.639]    [Pg.213]    [Pg.322]    [Pg.632]    [Pg.23]    [Pg.545]    [Pg.330]    [Pg.354]    [Pg.302]    [Pg.446]    [Pg.228]    [Pg.20]    [Pg.708]    [Pg.350]    [Pg.560]    [Pg.101]   