Mass magnetic field

The source is brought to a. positive poteptial (I/) of several kilovolts and the ions are extracted by a plate at ground potential. They acquire kinetic energy and thus velocity according to their mass and charge. They enter a magnetic field whose direction is perpendicular to their trajectory. Under the effect of the field, Bg, the trajectory is curved by Lorentz forces that produce a centripetal acceleration perpendicular to both the field and the velocity. [Pg.47]

A measurement procedure has been developed that allows to determine the mass of the inclusions as well as their locations with respect to radius, angle, and depth (2). For the depth determination use is made of the approximate 1/R dependence of the magnetic field strength from the distance R to the inclusion When in a first measurement at a small lift off an inclusion is detected, the measurement is repeated at an increased lift off From the signal ratio the depth can be calculated or seen from a diagram like fig. 5a which was generated experimentally. After that, from calibration curves like fig. 5b the absolute value of the signal leads to the mass of the inclusion. [Pg.989]

The most widely used type of trap for the study of ion-molecule reactivity is the ion-cyclotron-resonance (ICR) [99] mass spectrometer and its successor, the Fourier-transfomi mass spectrometer (FTMS) [100, 101]. Figure A3.5.8 shows the cubic trapping cell used in many FTMS instmments [101]. Ions are created in or injected into a cubic cell in a vacuum of 10 Pa or lower. A magnetic field, B, confines the motion in the x-y... [Pg.810]

Figure Bl.7.18. (a) Schematic diagram of the trapping cell in an ion cyclotron resonance mass spectrometer excitation plates (E) detector plates (D) trapping plates (T). (b) The magnetron motion due to tire crossing of the magnetic and electric trapping fields is superimposed on the circular cyclotron motion aj taken up by the ions in the magnetic field. Excitation of the cyclotron frequency results in an image current being detected by the detector electrodes which can be Fourier transfonned into a secular frequency related to the m/z ratio of the trapped ion(s). Figure Bl.7.18. (a) Schematic diagram of the trapping cell in an ion cyclotron resonance mass spectrometer excitation plates (E) detector plates (D) trapping plates (T). (b) The magnetron motion due to tire crossing of the magnetic and electric trapping fields is superimposed on the circular cyclotron motion aj taken up by the ions in the magnetic field. Excitation of the cyclotron frequency results in an image current being detected by the detector electrodes which can be Fourier transfonned into a secular frequency related to the m/z ratio of the trapped ion(s).
Magnetic field separates particles according to their mass to charge ratio... [Pg.568]

If only ions with a single charge (z = 1) are considered, then with a constant magnetic field strength and constant accelerating voltage, the radius of arc depends on mass and, from Equation 24.3, Equation 24.4 is obtained. [Pg.176]

Deflection in a magnetic field of an ion beam consisting of increasing mass-to-chaige ratios, m/z,. .,, m,/z, and split into different trajectories (1-5), respectively. [Pg.177]

TOF mass spectrometers are very robust and usable with a wide variety of ion sources and inlet systems. Having only simple electrostatic and no magnetic fields, their construction, maintenance, and calibration are usually straightforward. There is no upper theoretical mass limitation all ions can be made to proceed from source to detector. In practice, there is a mass limitation in that it becomes increasingly difficult to discriminate between times of arrival at the detector as the m/z value becomes large. This effect, coupled with the spread in arrival times for any one m/z value, means that discrimination between unit masses becomes difficult at about m/z 3000. At m/z 50,000, overlap of 50 mass units is more typical i.e., mass accuracy is no better than about 50-100 mass... [Pg.191]

Certain regions of a mass spectrometer have no electric or magnetic fields to affect an ion trajectory (field-free regions). Figure 32.3 illustrates three such regions in a conventional double-focusing instrument. [Pg.226]

The system of electric and magnetic fields or lenses is called the ion optics of the mass spectrometer. Electric lenses correct aberrations in the shape of the ion beam. [Pg.405]

Another important property of electric and magnetic fields is their ability to separate ions according to their individual masses (m, mj,. .., m ) or, more strictly, their mass-to-charge ratio (mj/z, raji,. mjz). [Pg.405]

Ion cyclotron resonance analyzer. A device to determine the mass-to-charge ratio (m/z) of an ion in the presence of a magnetic field by measuring its cyclotron frequency. [Pg.429]

Magnetic analyzer. A direction-focusing device that produces a magnetic field perpendicular to the direction of ion travel. The effect is to bring to a common focus all ions of a given momentum with the same mass-to-charge (m/z) ratio. [Pg.429]

Magnetic-field scan. The usual method of producing a momentum (mass) spectrum in instruments. [Pg.434]


See other pages where Mass magnetic field is mentioned: [Pg.692]    [Pg.692]    [Pg.252]    [Pg.810]    [Pg.810]    [Pg.1332]    [Pg.1333]    [Pg.1355]    [Pg.1355]    [Pg.1355]    [Pg.2390]    [Pg.156]    [Pg.158]    [Pg.158]    [Pg.175]    [Pg.177]    [Pg.183]    [Pg.189]    [Pg.195]    [Pg.196]    [Pg.205]    [Pg.226]    [Pg.239]    [Pg.242]    [Pg.242]    [Pg.273]    [Pg.322]    [Pg.434]    [Pg.434]    [Pg.435]    [Pg.435]    [Pg.436]    [Pg.328]    [Pg.350]    [Pg.398]    [Pg.418]    [Pg.540]   
See also in sourсe #XX -- [ Pg.441 ]