Marker compound, unretained

Other Experimental Methods. It is probably suitable to discuss here column porous structure. Porous space of a conventional packed column consists of the interparticle volume (Vip—space around particles of packing) and pore volume (Vp— space inside porous particles). The sum of those two constitutes the column void volume. The void volume marker ( unretained ) should be able to evenly distribute itself in these volumes while moving through the column. Only in this case the statistical center mass of its peak will represent the true volume of the Uquid phase in the column. In other words, its chromatographic behavior should be similar to that of the eluent molecules in a monocomponent eluent. If a chosen void volume marker compound has some preferential interaction with the stationary phase compared to that of the eluent molecules, it will show positive retention and could not be used as void marker. If on the other hand it has weaker interaction, it will be excluded from the adsorbent surface and will elute faster than the real void time, meaning that it also could not be used. For any analytical applications (when no thermodynamic dependences are not extracted from experimental data), 10% or 15% error in the determination of the void volume are acceptable. It is generally recommended to avoid elution of the component of interest with a retention factor lower than 1.5. Accurate methods for the determination of the column void volume are discussed in Chapter 2. [Pg.130]

A second set of test compounds, along with the original fo markers, was then put together and a further set of experiments conducted. The results from these experiments are presented in Table 8.2. The main requirement for success was to maximise the number of compounds with k greater than 1 (i.e. the compound was retained at least twice as well as something unretained). The Daisopak column achieved this for seven out of the ten compounds tested, the Aquasil and Platinum EPS achieved it with six compounds and the Alkyl HB with five compounds. [Pg.328]

M where and ii are the retention times of the first- and second-eluted fractions, respectively, and to is the retention time of an unretained compound void volume marker), d) Resolution factor Rs = 2(t2 - ti)/ W] + Wi) where Wj and Are the band-widths of the first- and second-eluted fractions at the base-line level, respectively, e) Mono-MaNP ester. [Pg.308]


See other pages where Marker compound, unretained is mentioned: [Pg.2]    [Pg.58]    [Pg.72]    [Pg.97]    [Pg.16]    [Pg.1373]    [Pg.1723]    [Pg.292]    [Pg.58]    [Pg.2046]    [Pg.1301]    [Pg.1651]    [Pg.1636]   
See also in sourсe #XX -- [ Pg.165 , Pg.218 , Pg.397 ]




SEARCH



Marker compounds

Unretained marker

© 2024 chempedia.info