Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Manifold block

From the outlet of the probe, a ball valve or large ported valve should be installed. This valve should be opened completely. Downstream of the probe valve, a short length of small diameter line should be run upgrade to the inlet port of the manifold block on the sampler. The sampler should be mounted above the sample point on a pipe stand. The hne to the sampler should always be sloped back toward the valve on the sample probe. This is to allow ai r free hquid to drain back into the pipeline. Free liquids should be discouraged from moving into the sample container. Two phase samplers in standard sample containers are difficult, if not impossible, to handle properly in the lab. [Pg.73]

Fig. 8. Injection manifold for injection molding of parisons. Individual nozzles are clamped to the manifold block, which houses a hot runner for the melt. Fig. 8. Injection manifold for injection molding of parisons. Individual nozzles are clamped to the manifold block, which houses a hot runner for the melt.
Figure 5.14 Principle of arrangement of tubular heaters in manifold block and division into heating zones. Tj and T2 are manifold temperatures. Figure 5.14 Principle of arrangement of tubular heaters in manifold block and division into heating zones. Tj and T2 are manifold temperatures.
FIGURE 2.68 Manifold block, single cavity for an eccentric gating of individual cavities... [Pg.393]

Flow channels should be streamlined to prevent slow or stagnant flow. Comers should be radiused by contoured end plugs. Manifold support pads should have minimal surface contact and should be furnished in materials of relatively low thermal conductivity such as stainless steel or titanium. Precise temperature control is necessary for consistent results. The temperature of the manifold block should be uniform throughout. Each nozzle should be provided with individual closed-loop control. [Pg.172]

Figure 10.3-39 shows an example of a substructure search in a catalog of fine chemicals. The precursor illustrated maybe needed, for instance, as a budding block for a compound library. The substructure search provides the avadable structural manifoldness for this precursor. [Pg.582]

All drum filters (except the single-compartment filter) utilize a rotary-valve arrangement in the drum-axis support trunnion to facih-tate removal of filtrate and wash hquid and to allow introduction of air or gas for cake blowback if needed. The valve controls the relative duration of each cycle as well as providing dead portions of the cycle through the use of bridge blocks. A typical valve design is shown in Fig. 18-121. Internal piping manifolds connect the valve with various sections of the drum. [Pg.1714]

A simple manifold is illustrated in Figure 40.41. This manifold contains one pressure inlet port and several pressure outlet ports that can be blocked off with threaded plugs. This type of manifold can be adapted to systems containing various numbers of subsystems. A thermal relief valve may be incorporated in this manifold. In this case, the port labeled T is connected to the return line to provide a passage for the relieved fluid to flow to the reservoir. [Pg.628]

Partitioning the operator manifold can lead to efficient strategies for finding poles and residues that are based on solutions of one-electron equations with energy-dependent effective operators [16]. In equation 15, only the upper left block of the inverse matrix is relevant. After a few elementary matrix manipulations, a convenient form of the inverse-propagator matrix emerges, where... [Pg.38]

Considering fi, v = 4f and 5d, eq 1 is a matrix with 12 by 12 elements, important for computation of the intensities of the transitions by distributing its elements over the whole manifold of the multielectron wave function. Considering the actual centrosymmetric Dw coordination of Eu2+, only the 7 by 5 elements corresponding to the off-diagonal (i//4fldah//sj) block... [Pg.5]

The dialysis membrane protects the microfluidic manifold from ingress of particulate matter that can block the narrow channels or damage valves/pumps. [Pg.139]

The sample of desorbed tritide is placed inside a quartz tube that is connected to a gas-handling manifold by a TorrSeal . A quartz sleeve with Silicon Carbide (SiC) in the annular space is placed around the end of the quartz tube, surrounding the sample with microwave susceptor. The quartz tube and susceptor sleeve are thermally insulated from the rest of the microwave cavity. An internal thermocouple measures the temperature of the sample and provides the temperature signal for process control of the desired temperature. A shine block (alumina foam), attached to the thermocouple, blocks radiant heating of the TorrSeal and the upper area of the quartz tube and manifold. An IR pyrometer is used as a secondary measure of the temperature of the susceptor, and therefore of the sample. A stainless steel shield reflects microwaves from the quartz tube not in the susceptor sleeve, eliminating the production of a plasma at low pressure in the quartz tube. [Pg.212]


See other pages where Manifold block is mentioned: [Pg.23]    [Pg.278]    [Pg.814]    [Pg.335]    [Pg.184]    [Pg.63]    [Pg.86]    [Pg.147]    [Pg.148]    [Pg.339]    [Pg.148]    [Pg.211]    [Pg.59]    [Pg.389]    [Pg.389]    [Pg.393]    [Pg.23]    [Pg.278]    [Pg.814]    [Pg.335]    [Pg.184]    [Pg.63]    [Pg.86]    [Pg.147]    [Pg.148]    [Pg.339]    [Pg.148]    [Pg.211]    [Pg.59]    [Pg.389]    [Pg.389]    [Pg.393]    [Pg.276]    [Pg.126]    [Pg.537]    [Pg.348]    [Pg.1087]    [Pg.147]    [Pg.16]    [Pg.628]    [Pg.159]    [Pg.473]    [Pg.161]    [Pg.475]    [Pg.136]    [Pg.1359]    [Pg.35]    [Pg.29]    [Pg.397]    [Pg.97]    [Pg.215]    [Pg.117]    [Pg.86]   
See also in sourсe #XX -- [ Pg.33 , Pg.364 ]




SEARCH



Manifolding

© 2024 chempedia.info