Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Low amplitude

A number of controls are provided to enable the user to tailor the colour, scale and orientation of the displayed image to highlight details of interest. Two types of colour map are available. The Default colour map is a cold-to-hot scheme in which with cold colours such as blue used for low amplitudes and hot colours such as red, yellow and white used for high amplitudes. The Mono colour map uses intensities of red, from black upwards, to indicate increasing amplitude. [Pg.771]

Microwave studies in molecular beams are usually limited to studying the ground vibrational state of the complex. For complexes made up of two molecules (as opposed to atoms), the intennolecular vibrations are usually of relatively low amplitude (though there are some notable exceptions to this, such as the ammonia dimer). Under these circumstances, the methods of classical microwave spectroscopy can be used to detennine the stmcture of the complex. The principal quantities obtained from a microwave spectmm are the rotational constants of the complex, which are conventionally designated A, B and C in decreasing order of magnitude there is one rotational constant 5 for a linear complex, two constants (A and B or B and C) for a complex that is a symmetric top and tliree constants (A, B and C) for an... [Pg.2441]

Vibrating screen, horizontal or inclined high-speed low-amplitude vibrating screens sifter screens static sieves centrifugal screens. [Pg.1771]

Relative motion between the meshing gears is oseillatory in the axial direetion and has a low amplitude and a relatively high frequeney. Some of the major advantages of the gear eouplings are ... [Pg.609]

If the combustion process within a gas explosion is relatively slow, then expansion is slow, and the blast consists of a low-amplitude pressure wave that is characterized by a gradual increase in gas-dynamic-state variables (Figure 3.7a). If, on the other hand, combustion is rapid, the blast is characterized by a sudden increase in the gas-dynamic-state variables a shock (Figure 3.7b). The shape of a blast wave changes during propagation because the propagation mechanism is nonlinear. Initial pressure waves tend to steepen to shock waves in the far field, and wave durations tend to increase. [Pg.56]

Measurement of dynamic mechanical properties was carried out under tension mode using a viscoelasto-meter, (Rheovibron DDV-III-EP, M/s, Orientec Corp., Tokyo, Japan). Sample size was 3.5 cm x 6.5 mm x 2 mm. Testing was carried out at a low amplitude, 0.025 mm, over a temperature range of - 100°C to +200°C. Heating rate was TC/min and frequency of oscillation was 3.5 Hz or 110 Hz. [Pg.442]

The key point to remember is that a very low amplitude energy source can cause massive amplitudes when its frequency coincides with the natural frequency of a machine or structure. Higher levels of input energy can cause catastrophic, near instantaneous failure of the machine or stmcture. [Pg.740]

Another modification to the slow strain-rate test involves the superimposition of a low amplitude sine wave ripple on the slow uniform extension (Fig. 8.47). In effect this produces higher strain rates (which appear to be more damaging for hydrogen embrittlement), while still giving a long test duration, with adequate time for the accumulation of hydrogen in the steeps. [Pg.1248]

The importance of amplitude of slip is emphasised above. In recent years, the area of very low amplitudes and very carefully controlled amplitudes has been investigated. These researches confirm that the specific wear rate (volume removed, per unit distance of sliding per unit applied load) increases dramatically in the region 30-70 /xm and then becomes constant, as would be expected in reciprocating or unidirectional sliding . Damage is produced at amplitudes of 1 /xm or less", but it tends to be characteristic of surface fatigue rather than wear. [Pg.1338]

Electrochemical noise This is a non-perturbation method and is defined as random low frequency low amplitude fluctuations either of the potential or current in a corroding system. Analysis of the corrosion potential noise can provide information relating to both the mechanism and kinetics of the cor-... [Pg.1140]

As we relax in preparation for and pass into sleep, the active desynchronised awake EEG characterised by the low-amplitude (5-10 pV) high-frequency (10-30 Hz) beta waves becomes progressively more synchronised giving larger (20-30 pV) and slower (8-12 Hz) alpha waves, and then even slower (1-4 Hz) and bigger (30-150 pV) delta waves. This so-called slow-wave sleep is interrupted at intervals of some 1-2h by the break-up and desynchronisation of the EEG into an awake-like pattern. Since this is accompanied by rapid eye movements, even though sleep persists and can be deeper, the phase is known as rapid eye movement, REM or paradoxical, sleep. It is a time when dreaming occurs and when memory may be secured. [Pg.134]

In electrochemical measurements, a method often employed is that of applying an alternating current of low amplitude to the electrode. For sinusoidal ac i = sin tof is the amplitude and co the angular frequency), the concentration gradient at the surface varies according to the law... [Pg.187]

Figure 5.7 Comparison of four-parameter fy-maxi mum, v-minimum. IC50, and h) and two-parameter (IC50 and h) fits of non-ideal concentration-response data. In panels A and B the data indicate a nonzero plateau at low inhibitor concentration that might reflect a low-amplitude, high-affinity second binding interaction. In panels C and D the data indicate a plateau at high inhibitor concentration that does not achieve full inhibition of the enzyme. There could be multiple causes of behavior such as that seen in panels C and D. One common cause is low compound solubility at the higher concentrations used to construct the concentration-response plot. Note that the discordance between the experimental data and the expected behavior is most immediately apparent in the plots that are fitted by the two-parameter equation. Figure 5.7 Comparison of four-parameter fy-maxi mum, v-minimum. IC50, and h) and two-parameter (IC50 and h) fits of non-ideal concentration-response data. In panels A and B the data indicate a nonzero plateau at low inhibitor concentration that might reflect a low-amplitude, high-affinity second binding interaction. In panels C and D the data indicate a plateau at high inhibitor concentration that does not achieve full inhibition of the enzyme. There could be multiple causes of behavior such as that seen in panels C and D. One common cause is low compound solubility at the higher concentrations used to construct the concentration-response plot. Note that the discordance between the experimental data and the expected behavior is most immediately apparent in the plots that are fitted by the two-parameter equation.
Thakkar, M., Portas, C. McCarley, R. W. (1996). Chronic low-amplitude electrical stimulation of the laterodorsal tegmental nucleus of freely moving cats increases REM sleep. Brain Res. 723, 223-7. [Pg.81]

In an EIS experiment, a low amplitude (5 to 10 mV peak-to-peak) sine wave potential signal is superimposed on a fixed DC potential applied to an electrochemical system. Based on Ohm s law, the impedance can be computed from the applied sinusoidal potential and the measured sinusoidal current. As the sinusoidal potential and current will... [Pg.158]

The morphological stability of initially smooth electrodeposits has been analyzed by several authors [48-56]. In a linear stability analysis, the current distribution on a low-amplitude sinusoidal surface is found as an expansion around the distribution on the flat surface. The first order current distribution is used to calculate the rate of amplification of the surface corrugation. A plot of amplification rate versus mode number or wavelength separates the regimes of stable and unstable fluctuation and... [Pg.160]

In REM sleep, there is a low-amplitude, mixed-frequency electroencephalogram, increased electric and metabolic activity, increased cerebral blood flow, muscle atonia, poikilothermia, vivid dreaming, and fluctuations in respiratory and cardiac rate. [Pg.827]


See other pages where Low amplitude is mentioned: [Pg.38]    [Pg.42]    [Pg.1559]    [Pg.2445]    [Pg.22]    [Pg.735]    [Pg.573]    [Pg.147]    [Pg.28]    [Pg.91]    [Pg.748]    [Pg.1338]    [Pg.1055]    [Pg.370]    [Pg.388]    [Pg.1060]    [Pg.1135]    [Pg.305]    [Pg.482]    [Pg.152]    [Pg.300]    [Pg.542]    [Pg.61]    [Pg.123]    [Pg.115]    [Pg.357]    [Pg.357]    [Pg.203]    [Pg.163]    [Pg.333]    [Pg.432]    [Pg.117]   
See also in sourсe #XX -- [ Pg.72 ]




SEARCH



High-velocity low-amplitude thrusting techniques

Large-amplitude potential step low coverage

Low amplitude signal

Low strain amplitude

Low-amplitude oscillatory shear

Low-amplitude perturbation

© 2024 chempedia.info