Loop configuration

Ammonia Synthesis and Recovery. The purified synthesis gas consists of hydrogen and nitrogen in about 3 1 molar ratio, having residual inerts (CH Ar, sometimes He). The fresh make-up gas is mixed with the loop recycle and compressed to synthesis pressures. AH modern synthesis loops recycle the unreacted gases because of equiUbrium limitations to attain high overall conversions. The loop configurations differ in terms of the pressure used and the point at which ammonia is recovered. [Pg.350]

Open-loop systems have inherently long residence times which may be detrimental if the retentate is susceptible to degradation by shear or microbiological contamination. A feed-bleed or closed-loop configuration is a one-stage continuous membrane system. At steady state, the upstream... [Pg.298]

The Smith predictor is a model-based control strategy that involves a more complicated block diagram than that for a conventional feedback controller, although a PID controller is still central to the control strategy (see Fig. 8-37). The key concept is based on better coordination of the timing of manipulated variable action. The loop configuration takes into account the facd that the current controlled variable measurement is not a result of the current manipulated variable action, but the value taken 0 time units earlier. Time-delay compensation can yield excellent performance however, if the process model parameters change (especially the time delay), the Smith predictor performance will deteriorate and is not recommended unless other precautions are taken. [Pg.733]

The CCD detector and the potentiostat were synchronized in an open-loop configuration by starting the experiment with a common trigger. Careful measurements... [Pg.380]

The USP Apparatus 4, also known as the flow-through cell, was introduced and extensively studied by Langenbucher (22). In the open loop configuration, this system offers the advantage of unlimited medium supply, which is of particular interest for the dissolution of poorly soluble drugs. The idea to develop a flow-through cell method dates back more than 45 years. As early as 1957, a flow-through cell method with a... [Pg.21]

For the case of impossible 3-D reactor or vessel sampling, this upward-flowing pipeline sampler should be implemented with the reactor in a recirculation loop configuration, as shown in Figure 3.20. The only new requirement is a low-power pump, to be operated full-time for all systems where this is feasible. [Pg.63]

Figure. 3.20 Colocation of correct upstream sampler and PAT sensor, shown here for a recirculation loop configuration (right). The PAT sensor is deployed in upstream small-diameter piping with a field of view matching as best possible the same stream segment which is being sampled for reference analysis. This setup allows for reliable multivariate calibration because of the colocated [X, f] modalities. Figure. 3.20 Colocation of correct upstream sampler and PAT sensor, shown here for a recirculation loop configuration (right). The PAT sensor is deployed in upstream small-diameter piping with a field of view matching as best possible the same stream segment which is being sampled for reference analysis. This setup allows for reliable multivariate calibration because of the colocated [X, f] modalities.
This configuration has still another potential bonus. For the upstream sampler, especially in the loop configuration, it is not advantageous to employ large-diameter piping. Indeed it is optimal to specifically use a narrow diameter. [Pg.64]

Figure 3.21 Alternative PAT sensor configuration/deployment in bypass loop configuration. Note that the field of view is here equal to the full stream cross section. Various combinations of the principles illustrated in Figures 3.20 and 3.21 offers convenient process technology flexibility to deal with just about any conceivable scenario otherwise threatened by the traditional fatal IDE/IEE issues illustrated in this chapter. Figure 3.21 Alternative PAT sensor configuration/deployment in bypass loop configuration. Note that the field of view is here equal to the full stream cross section. Various combinations of the principles illustrated in Figures 3.20 and 3.21 offers convenient process technology flexibility to deal with just about any conceivable scenario otherwise threatened by the traditional fatal IDE/IEE issues illustrated in this chapter.
Fig. 7.77. Alternative control loop configurations for a system with two inputs and... Fig. 7.77. Alternative control loop configurations for a system with two inputs and...
The two larger numbers (i.e. 0.75) indicate the recommended control loop configuration (i.e. that with the smaller amount of interaction) which is constructed by coupling C2 with A/Vl and C, with Mv2 (Fig. 7.776). [Pg.660]

Other transfer functions can be similarly derived for other sampler and control loop configurations (see also Example 7.16 and Section 7.17.8). [Pg.679]

The major market for membrane bioreactors is represented by wastewater treatment with the use of submerged modules configuration. These are considered among the best available technologies by the European Directives on Environment. Membrane bioreactors are also applied in food, red and white biotechnology. In these cases, the external loop configuration is used. [Pg.576]

There are also special cells for use with USP Apparatus 4 in a closed-loop configuration. Using a 100 mL bottle, a total volume of dissolution media ranges from 25 to 100 mL. For very low volume assembly, a test tube with a rubber stopper allowing for inlet and outlet tubing can be used. However, with the need for even smaller volumes, internal modifications should be made to the apparatus to minimize the impact on functionality due to a change in the internal tubing volumes. Also, the additional volume of the flow cell must be considered. For example, the implant... [Pg.269]

Schick and Harvey (49) summarize an interesting investigation of the effect of the choice of solvent on the conformation of a polymer adsorbed at the solution interface with Spheron 6 carbon black. A noteworthy conclusion concerns the occurrence of extended and looped configurations of the adsorbed polymer molecules formed from good or poor solvents, respectively. [Pg.13]

Figure 6.14 Computer-controlled phase-locked loop configuration for two-porl AW device measurements. The computer adjusts the output frequency of the synthesized frequency source to keep the phase delay between transducers, as measured by the vector... Figure 6.14 Computer-controlled phase-locked loop configuration for two-porl AW device measurements. The computer adjusts the output frequency of the synthesized frequency source to keep the phase delay between transducers, as measured by the vector...
The main advantage of the computer-controUed phase-locked loop configuration is that it is nearly as rugged as the fixed-frequency perturbation measurement system in terms of continuing to function during large changes in at-... [Pg.374]

An 8 column SMB with a 2-2-2-2 closed-loop configuration is considered. Available for the controller are the on-line concentration measurements at the two outlets of extract and raffinate. The substances to be separated are A and B, where A adsorbs stronger than B. Linear adsorption behaviour has been assumed (qj=Hi-Ci). The Henry constants Hi have been chosen as Ha=4 and Hb=2. The controller is able to adjust the external flow rates in order to change the internal flow rates in the four sections of the SMB, which are the manipulated variables. Since all 4 internal flow rates cannot be directly controlled via the external flow rates, one internal flow rate has to be directly controlled by an additional pump, which... [Pg.179]

The experiments using sprays were performed in both open and closed loop configurations. In the closed loop configuration, the experiments eould be performed with varying total system pressures and air partial pressures. [Pg.236]


See other pages where Loop configuration is mentioned: [Pg.326]    [Pg.119]    [Pg.381]    [Pg.199]    [Pg.1752]    [Pg.409]    [Pg.145]    [Pg.28]    [Pg.160]    [Pg.179]    [Pg.78]    [Pg.179]    [Pg.251]    [Pg.251]    [Pg.606]    [Pg.145]    [Pg.200]    [Pg.309]    [Pg.621]    [Pg.93]    [Pg.355]    [Pg.653]   
See also in sourсe #XX -- [ Pg.199 , Pg.316 , Pg.317 ]




SEARCH



Closed-loop configuration

Open loop configuration

Synthesis loop configurations