Linearity method development

We now discuss the most important theoretical methods developed thus far the augmented plane wave (APW) and the Korringa-Kolm-Rostoker (KKR) methods, as well as the linear methods (linear APW (LAPW), the linear miiflfm-tin orbital [LMTO] and the projector-augmented wave [PAW]) methods. [Pg.2210]

The approximate method developed is constructive in the following sense. If A is a linear operator, then the equation (1.105) is linear too and, therefore, it can be solved by standard numerical methods. [Pg.41]

Method Transfer. Method transfer involves the implementation of a method developed at another laboratory. Typically the method is prepared in an analytical R D department and then transferred to quahty control at the plant. Method transfer demonstrates that the test method, as mn at the plant, provides results equivalent to that reported in R D. A vaUdated method containing documentation eases the transfer process by providing the recipient lab with detailed method instmctions, accuracy and precision, limits of detection, quantitation, and linearity. [Pg.369]

In order to achieve a high aceuraey, it would seem desirable to explicitly include terms in the wave functions which are linear in the intereleetronie distanee. This is the idea in the R12 methods developed by Kutzelnigg and co-workers. The first order correction to the HF wave funetion only involves doubly exeited determinants (eqs. (4.35) and (4.37)). In R12 methods additional terms are included which essentially are the HF determinant multiplied with faetors. [Pg.141]

Other features of an analytical method that should be borne in mind are its linear range, which should be as large as possible to allow samples containing a wide range of analyte concentrations to be analysed without further manipulation, and its precision and accuracy. Method development and validation require all of these parameters to be studied and assessed quantitatively. [Pg.269]

In order to reduce the complexity of the problem, several approximation schemes have been developed. In the BGK model, the collision integral is replaced by a simple local term ensuring that the well-known Maxwell distribution is reached at thermal equilibrium [16]. The linearization method assumes that the phase space distribution is given by a small perturbation h on top of a (local) Maxwell distribu-tion/o (see, e.g., [17, 18]) ... [Pg.132]

Additionally, Breiman et al. [23] developed a methodology known as classification and regression trees (CART), in which the data set is split repeatedly and a binary tree is grown. The way the tree is built, leads to the selection of boundaries parallel to certain variable axes. With highly correlated data, this is not necessarily the best solution and non-linear methods or methods based on latent variables have been proposed to perform the splitting. A combination between PLS (as a feature reduction method — see Sections 33.2.8 and 33.3) and CART was described by... [Pg.227]

Currently, nutrient analytical methods development often utilizes the method of standard additions as an intrinsic aspect of the development process. Essentially, the analyte to be measured exists in the matrix to which an identical known pure standard is added. The spiked and non-spiked matrix is extracted and analysed for the nutrient of interest. By spiking at increasing levels the researcher can establish, to some degree of certainty, the recovery and linearity of the standard additions. One can also evaluate data to determine reproducibility, precision, and accuracy. Unfortunately, the method of standard additions does not allow the evaluation of the method at nutrient concentrations less than 100 % of the endogenous level. [Pg.288]

A significant development in pipeline network computation in the last few years was the introduction of the so-called linearization method first by Wood and Charles (Wll) and later, independently, by Bending and Hutchi-... [Pg.155]

The method development process with the multisorbent plate consists of three steps. In step 1, the sorbent chemistry and the pH for loading, washing, and elution are optimized. In step 2, optimization of the percentage organic for wash and elution and the pH of the buffer needed is carried out. Step 3 is validation the method developed from the results of the previous two steps is tested for linearity, limits of detection, quantitation of recovery, and matrix effects using a stable isotope-labeled analyte as an IS. [Pg.28]

Are the model results accurate enough considering the piecewise linear approximation methods developed Here, piecewise linear approximation accuracy is modified with additional points added in the approximation and result accuracy as well as model run time compared. [Pg.215]

The method developed for linear constraints is extended to nonlinearly constrained problems. It is based on the idea that the nonlinear constraints linear Taylor series expansion around an estimation of the solution (xi, ut). In general, measurement values are used as initial estimations for the measured process variables. The following linear system of equations is obtained ... [Pg.103]

The subject of liquid jet and sheet atomization has attracted considerable attention in theoretical studies and numerical modeling due to its practical importance.[527] The models and methods developed range from linear stability models to detailed nonlinear numerical models based on boundary-element methods 528 5291 and Volume-Of-Fluid (VOF) method. 530 ... [Pg.320]

The number of gas molecules can be measured either directly with a balance (gravimetric method) or calculated from the pressure difference of the gas in a fixed volume upon adsorption (manometric method). The most frequently apphed method to derive the monolayer capacity is a method developed by Brunauer, Emmett, and Teller (BET) [1], Starting from the Langmuir equation (monolayer adsorption) they developed a multilayer adsorption model that allows the calculation of the specific surface area of a sohd. The BET equation is typically expressed in its linear form as... [Pg.128]

It is a guiding principle of this book to generate all the data that subsequently are analysed by the methods developed for the task. Thus, we need functions for the generation of spectra and chromatographic concentration profiles. Generally, we use Gaussians or linear combinations of Gaussians for the purpose. This is a matter of convenience rather than a necessity. [Pg.36]

The advantage of the use of linear horizontal development is the reduced developing time. In this case the gravitation does not decrease the mobility of the mobile phase more than in the traditional linear ascending development. Plates are placed horizontally in the chamber and the transport of the eluent is assured by a glass frit strip, a capillary split or any other method. Circular development techniques employ circular TLC plates, the mobile phase enters the centre of the plate and the development occurs out of the centre of the plate. The sample can be applied either onto the dry layer or onto the layer under the flow of the mobile phase. [Pg.9]


See other pages where Linearity method development is mentioned: [Pg.143]    [Pg.143]    [Pg.2212]    [Pg.93]    [Pg.63]    [Pg.454]    [Pg.868]    [Pg.349]    [Pg.83]    [Pg.141]    [Pg.224]    [Pg.359]    [Pg.761]    [Pg.32]    [Pg.194]    [Pg.10]    [Pg.615]    [Pg.113]    [Pg.62]    [Pg.418]    [Pg.53]    [Pg.154]    [Pg.474]    [Pg.253]    [Pg.8]    [Pg.99]    [Pg.232]    [Pg.11]    [Pg.163]    [Pg.349]    [Pg.356]    [Pg.403]    [Pg.585]    [Pg.588]    [Pg.277]   