Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Light intensity, units

B5 Gamborg s B5 medium, MS Murashige-Skoog medium, 1/2MS MS medium with inorganic elements at half strength. The following relationship describes the conversion to light intensity units 1000 lx = 13 E (m2s) 1 = 3.4 W nr2. [Pg.193]

Figure C3.2.4. Plot of the log of photocurrent against number of methyl units in a alkylsilane based monolayer self-assembled on a n silicon electrode. The electrode is immersed in a solution witli an electron donor. Best fits of experimental data collected at different light intensities ( ) 0.3 mW cm ( ) 0.05 mW cm. From [10]. Figure C3.2.4. Plot of the log of photocurrent against number of methyl units in a alkylsilane based monolayer self-assembled on a n silicon electrode. The electrode is immersed in a solution witli an electron donor. Best fits of experimental data collected at different light intensities ( ) 0.3 mW cm ( ) 0.05 mW cm. From [10].
Direct photography of drops in done with the use of fiber optic probes using either direct or reflected light. StiU or video pictures can be obtained for detailed analysis. The light transmittance method uses three components a light source to provide a uniform collimated beam, a sensitive light detector, and an electronic circuit to measure the amplified output of the detector. The ratio of incident light intensity to transmitted intensity is related to interfacial area per unit volume. [Pg.430]

Fig. 3.20. Conductivity of ZnO film Fig. 3.20. Conductivity of ZnO film <r as a function of light intensity 7, (in arbitrary units) under conditions of acetone photolysis (CHs-radicals generator) at 300 C Paceton = 3,8 Torr. a - ( A<r- 7, ). 6 - lg(a/o-max) - Ws y 1 Increase in 7. 2 - Decrease in 7. ...
Our results show that the network density (vg - 1/Q Q = swelling degree) of the crosslinked polymers is a function of the light intensity, the exposure time, the acrylate content, the molecular weight of the uncrosslinked silicone, and also of the length of the spacer group between the acrylate or methacrylate unit and the silicone backbone. Oxygen influences only the polymerization kinetics, but it does not influence the network density. [Pg.262]

Figure 3. The increase in the incident UV light intensity enhances the cross-linking rate, as indicated by the larger slopes of the elastic modulus (G ) plotted as a function of UV exposure time. The use of either the pulse or continuous modes of irradiation do not affect the rheological properties for the NOA 61 sample. Here, the frequency of oscillation is 10 rad/s and the intensities have units of mW cm 2. Figure 3. The increase in the incident UV light intensity enhances the cross-linking rate, as indicated by the larger slopes of the elastic modulus (G ) plotted as a function of UV exposure time. The use of either the pulse or continuous modes of irradiation do not affect the rheological properties for the NOA 61 sample. Here, the frequency of oscillation is 10 rad/s and the intensities have units of mW cm 2.
A voltammetric curve can be viewed in electrochemistry as the emission or absorption spectra in spectroscopy. The current density (i.e., the number of charges per unit of time and area) corresponds to the emitted or absorbed light intensity (the number of quanta per unit of time and area). Finally, when multiplied by the Faraday constant, the potential defines the energy of the system and can thus be treated as an analog of the light frequency, which can also gives energy when multiplied by the Planck constant. [Pg.12]

Formally speaking, these are not units of light intensity (energy per second per unit area) but there is no loss of generality. We will realize the need of using these units below, when dehning the Stokes shift. [Pg.20]

The de-excitation process can be experimentally observed by analyzing the temporal decay of the emitted light. In fact, the emitted light intensity at a given time t, is proportional to the density of centers de-excited per unit time,... [Pg.26]

Fignre 3.12 shows the operational scheme of a photoconduction detector. The incident light creates an electrical current and this is measured by a voltage signal, which is proportional to the light intensity. This proportional relation is provided by the fact that, in most photoconduction detectors, the density of carriers in the steady state is proportional to the number of absorbed photons per unit of time that is, proportional to the incident power. [Pg.89]

The light intensities delivered by light sources are usually expressed in units such as kcal s 1, kJ s 1, or erg s 1, and it is necessary to convert them into the appropriate units of mol L 1 s 1 before using them in the preceding equations. This is accomplished by a... [Pg.222]

The quantitative measurement of light intensity (candle power) at any instant and the light integral (total energy emitted, with units of candle-seconds/gram) can be affected by a variety of test parameters such as container diameter, burning rate, and the measuring equipment. Therefore, comparisons between data obtained from different reports should be viewed with caution. [Pg.187]


See other pages where Light intensity, units is mentioned: [Pg.200]    [Pg.200]    [Pg.717]    [Pg.118]    [Pg.12]    [Pg.350]    [Pg.362]    [Pg.394]    [Pg.360]    [Pg.365]    [Pg.370]    [Pg.21]    [Pg.351]    [Pg.518]    [Pg.13]    [Pg.322]    [Pg.140]    [Pg.285]    [Pg.161]    [Pg.160]    [Pg.447]    [Pg.36]    [Pg.134]    [Pg.226]    [Pg.62]    [Pg.184]    [Pg.462]    [Pg.611]    [Pg.152]    [Pg.257]    [Pg.37]    [Pg.42]    [Pg.309]    [Pg.244]    [Pg.529]    [Pg.222]    [Pg.84]    [Pg.165]    [Pg.23]   
See also in sourсe #XX -- [ Pg.17 ]




SEARCH



Light intensity, common units

© 2024 chempedia.info