Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Continuous light

The glow-worm Arachnocampa is distributed in New Zealand and Australia. The larvae emit blue light continuously from their light... [Pg.25]

When considering environment it generally becomes difficult since actual service conditions are most of the time unpredictable. As an example, there is a systematic difference in the frequency distributions of liquid water content in rain. It appears that the areas most likely to have high values of liquid water are where there is a plentiful supply of moisture and a high instability in the atmosphere. The lowest values of liquid water are obtained from the climatic areas of light continuous rains such as that found along the northwest coast of the United States. [Pg.108]

An electron not restricted to particular energy levels would release light continuously as it spiraled closer into the nucleus. A broad spectrum of colors would be observed rather than the distinct lines. [Pg.686]

Preparation of Protein Residue Sheets. Individual abdomen stratum corneum sheets were placed in 20 ml 1 2 0.8 chloroform methan-ol water and agitated lightly continually for 24 hours. The solution was then removed and replaced daily with methanol. Stratum corneum sheets were extracted for a total of two, four, seven or thirteen days. The extracted protein residue sheets were placed on Teflon sheets and dried in a vacuum oven (10- Torr, 25°C) for eight hours and then stored under vacuum. [Pg.244]

As the light continues to strike the detector surface this action leads to a gradual discharge of the capacitor. [Pg.136]

Sediment first order degradation ty, = 14400 h (estimated by EPIWIN, Wania Dugani 2003) photolysis half-lives on different matrices, indoors under artificial UV-light continuous t, = 40-60 h on sediment for outdoors under sunlight discontinuous ty, = 80 h on sediment for outdoor sunlight continuous t,/,(calc) = 30 on sediment (Sbdertrom et al. 2004)... [Pg.203]

Selenium is important because when light strikes the charged selenium, the charge disappears. The sections on the drum or belt struck by light have no charge. The sections not struck by light continue to have a charge. [Pg.529]

There are a variety of instruments available for the measurement of colour. Colorimeters usually determine the proportions of the primary additive lights which are necessary to match the colour reflected or transmitted by the sample under investigation. Spectrophotometers differ in that they record the intensity of the reflected light continuously over the whole spectral range. [Pg.634]

Fig. 48. AFM phase image of pSt-b-pBzA hybrid nanoparticle (sub) monolayer on mica. Domain assignments dark spots (polysilsesquioxane particles), dark corona around particles (tethered pSt, Mn=5,250 Mw/Mn=1.22) light continuous matrix (tethered pSt-b-pBzA), Mn= 27,280 Mw/Mn=1.48). Reprinted with permission from [338]. Copyright (2001) American Chemical Society. Fig. 48. AFM phase image of pSt-b-pBzA hybrid nanoparticle (sub) monolayer on mica. Domain assignments dark spots (polysilsesquioxane particles), dark corona around particles (tethered pSt, Mn=5,250 Mw/Mn=1.22) light continuous matrix (tethered pSt-b-pBzA), Mn= 27,280 Mw/Mn=1.48). Reprinted with permission from [338]. Copyright (2001) American Chemical Society.
Horizontal and Vcriical Control Plales. Input signals are applied to two sets of plales, one of which dellects the beam horizontally and ihe other vertically. Thus, it is possible to display an x-y plot of two related signals on the face of the CR T when the switch in I igure 2-25 is in position I. Because the screen is phosphorescent, the movement of the dot appears as a lighted continuous trace iliat fades after a brief period. [Pg.52]

FIGURE 11.20 First atomic levels involved of singly-ionized calcium (Call) for the ion atomic clock at 729 nm (light continuous line). One of the bold continuous line (397nm) indicates the transition used for the laser cooling process and the second other one (866 nm) permits the back pumping from the Dj/j toward the cooling cycle. [Pg.358]

Figure 5. Ennanced Dl degradation induced by high light continues following transfer of cells to low light or dark for 1 hour. The cells were then incubated in H or L light or dark (D) as indicated for 3 hours. All incubations were carried out in the presence of 200ug/ml chloramphenicol. Residual Dl was quantitated by western blotting C. control untreated cells. Figure 5. Ennanced Dl degradation induced by high light continues following transfer of cells to low light or dark for 1 hour. The cells were then incubated in H or L light or dark (D) as indicated for 3 hours. All incubations were carried out in the presence of 200ug/ml chloramphenicol. Residual Dl was quantitated by western blotting C. control untreated cells.

See other pages where Continuous light is mentioned: [Pg.9]    [Pg.405]    [Pg.268]    [Pg.307]    [Pg.430]    [Pg.250]    [Pg.405]    [Pg.21]    [Pg.1008]    [Pg.250]    [Pg.320]    [Pg.70]    [Pg.163]    [Pg.209]    [Pg.413]    [Pg.202]    [Pg.121]    [Pg.13]    [Pg.120]    [Pg.412]    [Pg.24]    [Pg.25]    [Pg.6331]    [Pg.143]    [Pg.47]    [Pg.61]   
See also in sourсe #XX -- [ Pg.21 ]




SEARCH



Light continued

© 2024 chempedia.info