Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Least squares method linear fits

The best-fit values for kM and kd obtained by a non-linear least squares method were 3.8 x 10-4s-1 and 1.2 x 10-4M-1s-1 respectively. [Pg.265]

Kinetic analysis usually employs concentration as the independent variable in equations that express the relationships between the parameter being measured and initial concentrations of the components. Such is the case with simultaneous determinations based on the use of the classical least-squares method but not for nonlinear multicomponent analyses. However, the problem is simplified if the measured parameter is used as the independent variable also, this method resolves for the concentration of the components of interest being measured as a function of a measurable quantity. This model, which can be used to fit data that are far from linear, has been used for the resolution of mixtures of protocatechuic... [Pg.204]

Returns statistics that describe a linear trend matching known data points, by fitting a straight line usiig the least squares method. [Pg.126]

The methods used were those of Mitchell ( 1 ), Kurtz, Rosenberger, and Tamayo ( 2 ), and Wegscheider T ) Mitchell accounted for heteroscedastic error variance by using weighted least squares regression. Mitchell fitted a curve either to all or part of the calibration range, using either a linear or a quadratic model. Kurtz, et al., achieved constant variance by a... [Pg.183]

One other alternative for obtaming derivatives from experimental data is to fit the data to a function by the method of least squares, either linear or nonlinear, and then to obtain the derivative analytically. We carried out both procedures for Exercise 18.4(c), and the different procedures agreed very well. Another alternative is to use a software package for numerical differentiation that does not require equal intervals in the independent variable. In any case, it is preferable to use more than one method. [Pg.542]

The chemical mass balance method starts with a single column vector from the ambient data matrix, C]. This vector represents the chemical concentrations for the kth filter, which is combined with the best available estimates of the source compositions from the fractional composition matrix, Fij> to form a series of linear equations in which the Mj are the only unknowns. This set of equations is then solved by the least squares method to obtain the best fit of the ambient chemical data on a single filter. [Pg.79]

Low (<8.5) pH Solutions. The Np solution concentrations are plotted as a function of measured pe in Figure 2 for various equilibration periods. The data points for the low pH (<8.5) suspensions were fitted by a linear least squares method to a line of fixed unit slope. When the slopes were allowed to vary, their values ranged from 0.8 to 1.1. [Pg.137]

Figure 7.18 presents the data with the best fit linear equation given by the least squares method. [Pg.369]

The constant values of /iImax and were determined as listed in Table 5 by fitting the experimental data shown in Fig. 9 using the non-linear least squares method. [Pg.205]

For consecutive or parallel electrode reactions it is logical to construct circuits based on the Randles circuit, but with more components. Figure 11.16 shows a simulation of a two-step electrode reaction, with strongly adsorbed intermediate, in the absence of mass transport control. When the combinations are more complex it is indispensable to resort to digital simulation so that the values of the components in the simulation can be optimized, generally using a non-linear least squares method (complex non-linear least squares fitting). [Pg.245]

If the function may be made linear with respect to its unknown parameters by a suitable transformation, then it may be fitted by the Linearized Least Squares method (10) so as to minimize the root mean square error in the original (untransformed) space. The essence of this technique is to use weighted (linear) least squares to effect a non-linear least squares fit. Assume that the equation has been transformed into an equal variance space and let... [Pg.120]

Typke has introduced the rs-fit method [7] where Kraitchman s basic principles are retained. A system of equations is set up for all available isotopomers of a parent (not necessarily singly substituted) and is solved by least-squares methods for the Cartesian coordinates (referred to the PAS of the parent) of all atomic positions that have been substituted on at least one of the isotopomers The positions of unsubstituted atoms need not be known and cannot be determined. The method is presented here with two recent improvements true derivatives are used for the Jacobian matrix X, and the problem of the observations and theircovariances, which is rather elaborate, is fully worked out. The equations are always given for the general asymmetric rotor, noting that simplifications occur in more symmetric situations, e.g. for linear molecules, which could nonetheless be treated within the framework presented. [Pg.79]

Since the nonlinear least-squares method requires initial guesses to start the procedure, three different initial trials were performed (1) (0,0), (2) (1,1), and (3) the values obtained from the Lineweaver-Burk plot in Example 4.2.4. All three initial trials give the same result (and thus the same relative error). Note the large differences in the values obtained from the nonlinear analysis versus those from the linear regression. If the solutions are plotted along with the experimental data as shown below, it is clear that the Lineweaver-Burk analysis does not provide a good fit to the data. [Pg.122]

Fluorescence and affinity measurements - Peptide in 25 mM Tris, 100 mM KCl and 1 mM CaCl2 at pH 7.5 and 30 C was titrated with a stock solution of calmodulin in UV transmitting plastic cuvettes since the peptides appear to bind to glass. Fluorescence titration spectra were recorded using a SPEX FluoroMax fluorescence spectrometer with excitation at 280 nm and emission scanned from 310 to 390 nm. The value of fluorescence intensity at 330nm was plotted as a function of calmodulin concentration and fitted using standard non-linear least squares methods (6) to obtain optimal values of the dissociation constant (Kj) and the maximum fluorescence enhancement (F/F ). The detection limit under our experimental conditions was 50 nM peptide and all quoted Kj values are the average of at least 3 independent determinations. [Pg.403]

A number of statistical techniques exist for fitting a function to a set of scattered data. The application of the most common of these techniques—linear regression or the method of least squares—to the fitting of a straight line to a series of y versus jc data points is outlined and illustrated in Appendix A.l, and the use of this technique is required for the solution of Problems 2.39 through 2.42 at the end of this chapter. [Pg.30]


See other pages where Least squares method linear fits is mentioned: [Pg.2109]    [Pg.190]    [Pg.2109]    [Pg.86]    [Pg.63]    [Pg.244]    [Pg.514]    [Pg.693]    [Pg.172]    [Pg.260]    [Pg.133]    [Pg.158]    [Pg.161]    [Pg.350]    [Pg.33]    [Pg.246]    [Pg.176]    [Pg.269]    [Pg.185]    [Pg.280]    [Pg.77]    [Pg.66]    [Pg.160]    [Pg.279]    [Pg.206]    [Pg.207]    [Pg.47]    [Pg.168]    [Pg.34]    [Pg.89]    [Pg.54]    [Pg.393]    [Pg.170]    [Pg.534]    [Pg.637]   
See also in sourсe #XX -- [ Pg.73 , Pg.74 , Pg.666 , Pg.667 , Pg.668 , Pg.671 , Pg.672 , Pg.673 ]




SEARCH



Fitting methods

Least squares fit

Least squares linear

Least-Squares Fitting Methods

Least-squared method

Least-squares fit linear

Least-squares fitting

Least-squares fitting, linear

Least-squares method

Linear fit

Linear least-squares fitting methods

Linear methods

Linear-least-squares method

Linearized least squares method

Linearized methods

Non-linear least-squares fit method

© 2024 chempedia.info