Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Isoperibol titration calorimetry using heat flow

The historical development of titration calorimetry has been addressed by Grime [197]. The technique is credited to have been born in 1913, when Bell and Cowell used an apparatus consisting of a 200 cm3 Dewar vessel, a platinum stirrer, a thermometer graduated to tenths of degrees, and a volumetric burette to determine the end point of the titration of citric acid with ammonia lfom a plot of the observed temperature change against the volume of ammonia added [208]. The capabilities of titration calorimetry have enormously evolved since then, and the accuracy limits of modern titration calorimeters are comparable to those obtained in conventional isoperibol (chapter 8) or heat-flow instruments (chapter 9) [195,198],... [Pg.156]

The principles of titration calorimetry will now be introduced using isoperibol continuous titration calorimetry as an example. These principles, with slight modifications, can be adapted to the incremental method and to techniques based on other types of calorimeters, such as heat flow isothermal titration calorimetry. This method, which has gained increasing importance, is covered in section 11.2. [Pg.158]

Another area where titration calorimetry has found intensive application, and where the importance of heat flow versus isoperibol calorimetry has been growing, is the energetics of metal-ligand complexation. Morss, Nash, and Ensor [225], for example, used potenciometric titrations and heat flow isothermal titration calorimetry to study the complexation of UO "1" and trivalent lanthanide cations by tetrahydrofuran-2,3,4,5-tetracarboxylic acid (THFTCA), in aqueous solution. Their general goal was to investigate the potential application of THFTCA for actinide and lanthanide separation, and nuclear fuels processing. The obtained results (table 11.1) indicated that the 1 1 complexes formed in the reaction (M = La, Nd, Eu, Dy, andTm)... [Pg.169]

Chapter 9, by Kiraly (Hungary), attempts to clarify the adsorption of surfactants at solid/solution interfaces by calorimetric methods. The author addresses questions related to the composition and structure of the adsorption layer, the mechanism of the adsorption, the kinetics, the thermodynamics driving forces, the nature of the solid surface and of the surfactant (ionic, nonionic, HLB, CMC), experimental conditions, etc. He describes the calorimetric methods used, to elucidate the description of thermodynamic properties of surfactants at the boundary of solid-liquid interfaces. Isotherm power-compensation calorimetry is an essential method for such measurements. Isoperibolic heat-flux calorimetry is described for the evaluation of adsorption kinetics, DSC is used for the evaluation of enthalpy measurements, and immersion microcalorimetry is recommended for the detection of enthalpic interaction between a bare surface and a solution. Batch sorption, titration sorption, and flow sorption microcalorimetry are also discussed. [Pg.531]


See other pages where Isoperibol titration calorimetry using heat flow is mentioned: [Pg.164]    [Pg.169]    [Pg.185]    [Pg.6]   


SEARCH



Flow calorimetry

Heat calorimetry

Isoperibol calorimetry

Isoperibolic

Isoperibolic calorimetry

© 2024 chempedia.info