Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Integration maximum

Electricity, MW (electric) Potable water, mVday District heating, MW (thermal) Hi production mVday Target commercialisation date Licensing status Integral Maximum excess reactivity in hot full power state (HFP) ABC/K Modidar ... [Pg.11]

Witiiin any approximation level, TDQS measures will depend on the relative positions in space of the three molecular structures involved. An integral maximum will be reached when the three molecules are optimally superposed, in a similar way as previously discussed within the CQS3 of Ihe CQS series involving two molecular stmctures. [Pg.292]

Adaptations of this method have been proposed in order to take into account the band displacement due either to substitution on the aromatic ring, or to chains of different lengths. The variations consist, instead of measuring the absorbance at maximum absorption, of an integration of the absorbance curve over a specified range (Oelert s method, 1971). More exact, this method is used less often mainly because the Brandes method is simpler... [Pg.61]

The scope of the directive covers the design, manufacture and conformity assessment of pressure equipment and assemblies with a maximum allowable pressure greater than 0,5 bar. A pressure equipment in the sense of the directive is any vessel, piping, safety accessory or pressure accessory. An assembly means several pieces of pressure equipment assembled by a manufacturer to constitute an integrated and functional whole. It is important to be aware that the directive relates exclusively to the pressure risk and that therefore other directives, such as for machinery, low voltage may be applicable to the equipment concerned. [Pg.941]

It should be noted that the capacity as given by C, = a/E, where a is obtained from the current flow at the dropping electrode or from Eq. V-49, is an integral capacity (E is the potential relative to the electrocapillary maximum (ecm), and an assumption is involved here in identifying this with the potential difference across the interface). The differential capacity C given by Eq. V-50 is also then given by... [Pg.198]

One can introduce a distributed micleation rate J(R, f)dR for nucleating clusters of radius between R and R + dR. Its integral overi is the total micleation rate J(0- Equation (A3,3.1031 can be viewed as a radius-dependent droplet energy which has a maximum at = R. If one assumes j R, t) to be a Gaussian fiinction, then... [Pg.756]

IlyperChem uses 16 bytes (two double-precision words) of storage for each electron repulsion integral. The first 8 bytes save thecom-pressed four indices and the second S bytes store the value of the integral. Each index lakes 16 bits. Thus the maximum number of basis fiinctions is 65,535. This should satisfy all users of IlyperChem for the foreseeable future. [Pg.263]

For each atom there are a maximum of five one-center two-electron integrals, that is (ssiss), (ssipp), (spisp), (ppipp), and (ppip p ), where p and p are two different p-type atomic orbitals. It has been shown that the extra one-center two-electron integral, (pp Ipp ), is related to two of other integrals by... [Pg.290]

Figure 7.21 illustrates a particular case where the maximum of the v = 4 wave function near to the classical turning point is vertically above that of the v" = 0 wave function. The maximum contribution to the vibrational overlap integral is indicated by the solid line, but appreciable contributions extend to values of r within the dashed lines. Clearly, overlap integrals for A close to four are also appreciable and give an intensity distribution in the v" = 0 progression like that in Figure 7.22(b). [Pg.248]

Fig. 4. Physical zones of ablators. Typical time-integrated heat flux, J/m, (a) 500, (b) 5000, (c) <50 maximum instantaneous heat flux, MW/m, (a) 0.5,... Fig. 4. Physical zones of ablators. Typical time-integrated heat flux, J/m, (a) 500, (b) 5000, (c) <50 maximum instantaneous heat flux, MW/m, (a) 0.5,...
Paper may be coated either on equipment that is an integral part of the paper machine, ie, on-machine coating, or on separate converting equipment. Many plants include both types of coating equipment and utilize each to its maximum advantage for paper and paperboard. The combination of techniques is of particular value where more than one coating must be appHed to the sheet in order to obtain a product of desired quaUty. [Pg.9]


See other pages where Integration maximum is mentioned: [Pg.312]    [Pg.312]    [Pg.15]    [Pg.84]    [Pg.444]    [Pg.446]    [Pg.462]    [Pg.752]    [Pg.14]    [Pg.363]    [Pg.633]    [Pg.724]    [Pg.892]    [Pg.1425]    [Pg.1477]    [Pg.695]    [Pg.222]    [Pg.1286]    [Pg.100]    [Pg.601]    [Pg.33]    [Pg.290]    [Pg.299]    [Pg.545]    [Pg.546]    [Pg.547]    [Pg.32]    [Pg.267]    [Pg.244]    [Pg.511]    [Pg.43]    [Pg.3]    [Pg.345]    [Pg.313]    [Pg.25]   
See also in sourсe #XX -- [ Pg.82 ]




SEARCH



Process integration maximum energy recovery

© 2024 chempedia.info