Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Integration Coherence

Legare, F., Ganikhanov, F., and Xie, X. S. 2005. Towards an integrated coherent anti-Stokes Raman scattering (CARS) microscope system. Proc. SPIE 5971 35 0. [Pg.123]

The interplay of the bleak materiality of disease and mortality interwoven with the evocation of that materiality embodying its own self-reflexive, poetic transcendence - skin cried, a stable on a frosty night, Your face was talking to you - is powerful and potent. There is a carefully constructed, creative collision in this iconic dramatic memory of a face that talks to its owner through its meta-reflection. It evokes the relationship of the puppet to Joe in The Children. The signified inanimate and materialist entity is invested with life, identity and volition by the alienated, divided self who seeks an integrated coherence through the externalised Other. [Pg.116]

The path between any initial state (cq, Tq) and final state (Cg, Tq) may be deduced from the hodograph in the same way as for an isothermal binary system. Glueckauf s rule 1 allows the correct path to be selected from the two alternative coherent paths which may be drawn by following the characteristic curves. The distinction between a simple wave and a shock transition requires calculation of the wave velocities along the characteristics. A minor complication arises since the shock characteristic is no longer coincident with the characteristic for a simple wave transition and must be calculated separately from the equilibrium relation and the integral coherence condition [Eq. (9.41)]. [Pg.299]

For water, organic and water-organic metal salts mixtures the dependence of integral and spectral intensities of coherent and non-coherent scattered radiation on the atomic number (Z), density, oscillator layer thickness, chemical composition, and the conditions of the registering of analytical signals (voltage and tube current, tube anode material, crystal-analyzer) was investigated. The dependence obtained was compared to that for the solid probes (metals, alloys, pressed powder probes). [Pg.444]

The use of a number of components connected in this way implies that they are integrated into a coherent circuit with compressors, fans, solenoid valves etc. under a common control system. A few major manufacturers in the world are capable of engineering a complex system of this sort and supplying matching components and training the staff to instal and maintain it. [Pg.313]

Collection of interconnected subcortical and cortical brain structures (including hypothalamus, amygdala, and hippocampus) integrating multimodal intero- and exteroceptive information to produce coherent neuroendocrine and behavioral output, and to support memory functions. [Pg.690]

Reynaud, R, Lagorceix, H., 1996, Stabilization and control of a fiber array for the coherent transport of beams in a stellar interferometer, Proc. of the Conf. Astrofib 96 Integrated optics for astronomical interferometry, Ed. P. Kern and F. Malbet, 249... [Pg.306]

FIG. 14 Schematic illustration of an archaeal cell envelope structure (a) composed of the cytoplasmic membrane with associated and integral membrane proteins and an S-layer lattice, integrated into the cytoplasmic membrane, (b) Using this supramolecular construction principle, biomimetic membranes can be generated. The cytoplasmic membrane is replaced by a phospholipid or tetraether hpid monolayer, and bacterial S-layer proteins are crystallized to form a coherent lattice on the lipid film. Subsequently, integral model membrane proteins can be reconstituted in the composite S-layer-supported lipid membrane. (Modified from Ref. 124.)... [Pg.363]

Application to heterogeneous polymer solids, and elastic composites, is presented in the Section 7 (Gusev, Suter), which is followed by a summary and the outlook for the various methods reviewed here. It will be apparent to the reader that this review thus assembles several building blocks for the difficult task to bridge the gaps from the atomistic to the macroscopic scales in space and times for the simulation of polymeric materials. Integrating these building blocks into one coherent framework still is not fully solved and a matter of current research. [Pg.51]

It is clear, that the various modes of LSV at the dme require an integrated and coherent regulation of sweep time, current sampling and drop knocking, preferably by an electronic device and on with computer guidance. A disadvantage of LSV. at the dme, in contrast to normal DC polarography, is that for mixtures of components the latter yields a simple evaluation by curve extrapolation on the basis of additivity [see Fig. 3.34(a)], whereas the former suffers from an uncertain evaluation [see Fig. 3.34(b)],... [Pg.159]

Figure 13 Timing diagram for the clean HMBC experiment with an initial second-order and terminal adiabatic low-pass 7-filter.42,43 The recommended delays for the filters are the same than for a third-order low-pass J filter. <5 and 8 are gradient delays, where 8 — <5 + accounts for the delay of the first point in the 13C dimension. The integral over each gradient pulse G, is H/2yc times the integral over gradient G2 in order to achieve coherence selection. The recommended phase cycle is c/)n = x, x, x, x 3 — 4(x), 4(y), 4( x), 4(—y) with the receiver phase c/)REC = x, x. Figure 13 Timing diagram for the clean HMBC experiment with an initial second-order and terminal adiabatic low-pass 7-filter.42,43 The recommended delays for the filters are the same than for a third-order low-pass J filter. <5 and 8 are gradient delays, where 8 — <5 + accounts for the delay of the first point in the 13C dimension. The integral over each gradient pulse G, is H/2yc times the integral over gradient G2 in order to achieve coherence selection. The recommended phase cycle is c/)n = x, x, x, x <p2 = x, x, 4 (—x), x, x and </>3 — 4(x), 4(y), 4( x), 4(—y) with the receiver phase c/)REC = x, x.
The parameters, mentioned however, have not been clearly interpreted in terms of quality, i.e. what aspect of quality is measured The IQC provides a framework for further investigations to demonstrate the meaning of these parameters. In the apple and carrot experiments of the Louis Bolk Instituut, we demonstrated some experimental parameters in food products grown with different balances between growth and differentiation. Biocrystallisation pictures in particular, are able to show both the life processes of growth and differentiation, and their integration. In future we expect to find the key to work out the relevance of coherence for health in the balance (the integration) between the life processes. [Pg.61]

An integral part of a fibre optic sensor is the light source. Its primary task is to deliver an appropriate light, which possesses such features as an optical power suitable to interact with an analyte or an indicator from the optrode, a wavelength matched to the spectral properties of the sensors in order to obtain the highest sensitivity, and, in dependence on the construction of the sensor, polarisation, short pulse etc. There are many various light sources utilised in the fibre optic chemical sensors. They differ in spectral properties, generated optical power and coherence. [Pg.51]


See other pages where Integration Coherence is mentioned: [Pg.319]    [Pg.44]    [Pg.217]    [Pg.297]    [Pg.349]    [Pg.268]    [Pg.344]    [Pg.319]    [Pg.44]    [Pg.217]    [Pg.297]    [Pg.349]    [Pg.268]    [Pg.344]    [Pg.235]    [Pg.260]    [Pg.1980]    [Pg.443]    [Pg.485]    [Pg.58]    [Pg.133]    [Pg.8]    [Pg.441]    [Pg.896]    [Pg.74]    [Pg.280]    [Pg.281]    [Pg.319]    [Pg.80]    [Pg.652]    [Pg.733]    [Pg.160]    [Pg.492]    [Pg.215]    [Pg.48]    [Pg.4]    [Pg.57]    [Pg.391]    [Pg.396]    [Pg.143]    [Pg.66]    [Pg.9]    [Pg.55]    [Pg.202]   
See also in sourсe #XX -- [ Pg.19 ]




SEARCH



© 2024 chempedia.info