Integrals fluorescence measurement

The 2PF technique measures the upconverted fluorescence induced by 2PA. This technique allows for the measurement of 2PA cross sections that are less than tens of GMs when the fluorescence quantum yield is large. The technique was first proposed by Kaiser et al. [76] in 1961 and represents an indirect way to measure the 2PA cross section, which can be calculated by comparing the integrated fluorescence signal... [Pg.123]

Figure 23 Fluorescence spectrum of DMP measured at 100 nsec after e. Energy of / V532, 130 mJ. Inset a plot of the integrated fluorescence intensity of DMP as a function of the delay time of hv532 relative to eT (open circle) is superimposed with a plot of AO.D.575 (solid circle). Figure 23 Fluorescence spectrum of DMP measured at 100 nsec after e. Energy of / V532, 130 mJ. Inset a plot of the integrated fluorescence intensity of DMP as a function of the delay time of hv532 relative to eT (open circle) is superimposed with a plot of AO.D.575 (solid circle).
By far most of the work discussed in this review has been based on LIF detection, usually with an 488 nm Ar-ion laser as the excitation source. Only very few other examples exist in the literature where other detection principles were investigated. One of these exceptions is an integrated detection cell for chip CE that has been described by Liang et al. [78]. In combination with the U-shaped separation channel, two additional well aligned channels to take up the excitation and collection fibers where micromachined in a glass plate. The U-cell provides a longitudinal path of 120 -140 pm in length parallel to the flow direction and can be used both for absorption and fluorescence measurements. The absorption detection limit was 0.003 AU ( 6 pM of a fluorescein dye) in the fluorescence mode a detection limit of 3 nM fluorescein (20 000 molecules) was achieved. [Pg.75]

However, in an attempt to integrate the SFA and spectroscopic techniques, the use of silver for optical interferometry has been seen as a drawback due to the fact that it precluded sufficient excitation source intensity to illuminate the buried interface. In order to circumvent this problem Mukhopadhyay and co-workers in an experimental set-up where the SFA was combined with fluorescence correlation spectroscopy (FCS) used, instead of silver, multilayer dielectric coatings that allowed simultaneous interferometry and fluorescence measurements in different regions of the optical spectrum [75]. Using this set-up they succeeded in measuring diffusion in molecularly thin films with singlemolecule sensitivity. [Pg.31]

In a very new report, Fujino et al. challenge the two-isomerization-mechanism concept on the basis of their time-resolved and time-integrated femtosecond fluorescence measurements of B-azobenzene following excitation of the (7t,7t ) State. They use the extremely weak fluorescence (cf. Figure 1.8) as an indicator for the population of the emitting state. From the ratios of their measured fluorescence lifetimes (S2 0.11 ps Sp 0.5 ps) and the radiative lifetimes deduced from the (absorption-spectra-based) oscillator strengths, they determine the fluorescence quantum yields 2.5310 for the emission and 7.5410" for the Si—>So emission. By comparison... [Pg.36]

Second, we considered the mid-wavelength component, which was only observed in the elicitor-treated cells. This suggests the possibility that the component is associated with avenanthramides. It was reported that avenanthramide A is a major component of induced avenanthramides and reaches a maximum at 36-48 h after treatment with the elidtor [32].We measured the time-resolved fluorescence spectrum of avenanthramide A in aqueous solution (pH. 7.0) in vitro. The time-integrated fluorescence spectrum is broad and centered at 510 nm (Figure 32.11a). The spectral shape is, in part, similar to that of P2 and very similar to that of Component II. The... [Pg.357]

Fluorescence measurements were performed with an SLM 8000 fluorometer. Quantum yields were obtained with quinine bisulfate as the standard (14,15). Excitation was at 272-280 nm, and the range of the integration used in the determination of 1/1(0) was 285-420 nm. Circular dichroism measurements were performed with a Jasco J-500C spectropolarimeter. [Pg.163]

Figure 6. (a) Fluorescence signal measured from three consecutive bead patterns after performing an immunoassay in stop-flow mode using a sample volume of 1,300 nL at different m-Ag antigen concentrations, (b) Integrated fluorescence obtained from fluorescent intensity profiles like shown in Fig. 6a for three different volumes of t-Ag solution exposing the bead patterns [17]. [Pg.462]

General procedure. The excitation and emission spectra of fluorescence were measured at room temperature and optimum excitation and emission wavelengths were selected from these spectra. Three mL of rutin and 1 mL of lxl0-4 mol/L Fe(III) were taken into a vial, mixed well and stood for 5 min. The content of the vial was made up to 10 mL with distilled water. The fluorescence intensity of the system was then measured in a 1 cm quartz cell. The fluorescence intensity of the solution was measured at 506 nm with excitation at 491 nm. All fluorescence measurements were made using 1 nm increment, 1 s integration time, S acquisition mode and YES auto zero. [Pg.386]

Ionic recombination rate constants were determined as described for XeF, by analyzing the later, linear, portion of the transformed kinetic curve and using ozone dosimetry and integrated kinetic traces. The overall exciplex fluorescence was isolated by subtraction of the X-ray and dimer xenon fluorescence intensities from the integrated fluorescence as before. However, the experimental resolution of the exciplex fluorescence yield into neutral reaction and ionic recombination components was not experimentally possible for this system. Therefore the fractional yields for each of the XeBr formation pathways, excited state reaction and ionic recombination, were calculated using experimental measurements of relative XeBr emission yields. [Pg.132]


See other pages where Integrals fluorescence measurement is mentioned: [Pg.504]    [Pg.233]    [Pg.59]    [Pg.67]    [Pg.647]    [Pg.154]    [Pg.162]    [Pg.359]    [Pg.359]    [Pg.162]    [Pg.53]    [Pg.54]    [Pg.82]    [Pg.145]    [Pg.15]    [Pg.46]    [Pg.185]    [Pg.27]    [Pg.167]    [Pg.311]    [Pg.219]    [Pg.202]    [Pg.82]    [Pg.52]    [Pg.405]    [Pg.190]    [Pg.358]    [Pg.39]    [Pg.162]    [Pg.168]    [Pg.195]    [Pg.276]    [Pg.349]    [Pg.16]    [Pg.27]    [Pg.186]    [Pg.558]    [Pg.170]    [Pg.291]    [Pg.426]   
See also in sourсe #XX -- [ Pg.422 ]