Injection magnet

A typical configuration, often used in general-purpose AMS systems, is shown in Figure 16.3 an electrostatic analyser after the exit of the ion source followed by an injection magnet. [Pg.468]

Beck et al. [61] used flow injection magnetic sector ICP-MS to determine cadmium, copper, nickel, zinc, and manganese in estuarine waters. The online preconcentration system used Toyopearl A-T Chelate 650 H as chelating resin, and was validated for an alkaline water standard reference material (SLEW-2). [Pg.339]

A standard of known content is moved into position in the ion source and the injection magnet set to accelerate mass 14. [Pg.343]

To normalize the measurement, the injection magnet is set to accelerate mass 13. The current is measured with a Faraday cup on the high energy side of the accelerator. The counting times are from 10 to 30 s. [Pg.343]

Matsuo T, Sugita T, Kubo T. Injectable magnetic liposomes as a novel carrier of recombinant human BMP-2 for bone formation in a rat bone-defect model. J Biomed Mater Res A 2003 66A 747-54. [Pg.157]

The most widely used type of trap for the study of ion-molecule reactivity is the ion-cyclotron-resonance (ICR) [99] mass spectrometer and its successor, the Fourier-transfomi mass spectrometer (FTMS) [100, 101]. Figure A3.5.8 shows the cubic trapping cell used in many FTMS instmments [101]. Ions are created in or injected into a cubic cell in a vacuum of 10 Pa or lower. A magnetic field, B, confines the motion in the x-y... [Pg.810]

SL/RN Process. In the SL/RN process (Fig. 4), sized iron ore, coal, and dolomite are fed to the rotary kiln wherein the coal is gasified and the iron ore is reduced. The endothermic heat of reduction and the sensible energy that is required to heat the reactants is provided by combustion of volatiles and carbon monoxide leaving the bed with air introduced into the free space above the bed. The temperature profile in the kiln is controlled by radial air ports in the preheat zone and axial air ports in the reduction zone. Part of the coal is injected through the centerline of the kiln at the discharge end. The hot reduced iron and char is discharged into an indirect rotary dmm cooler. The cooled product is screened and magnetically separated to remove char and ash. [Pg.429]

Following the tolerance stack through the end assembly, the bobbin dimension of 22 mm from the outside face to the back face of the magnetic pole is analysed next. This characteristic dimension does not include the tolerance on the impact extruded pole. The pole is to be moulded into the bobbin and the pole face is considered to be part of a mould related dimension. The bobbin is injection moulded using 30% filled polybutylene terephthalate (PBT). The tolerance assigned to the bobbin dimension is 0.035 mm. [Pg.101]


See other pages where Injection magnet is mentioned: [Pg.471]    [Pg.472]    [Pg.472]    [Pg.168]    [Pg.1215]    [Pg.266]    [Pg.287]    [Pg.341]    [Pg.110]    [Pg.394]    [Pg.2340]    [Pg.2465]    [Pg.2465]    [Pg.459]    [Pg.809]    [Pg.310]    [Pg.471]    [Pg.472]    [Pg.472]    [Pg.168]    [Pg.1215]    [Pg.266]    [Pg.287]    [Pg.341]    [Pg.110]    [Pg.394]    [Pg.2340]    [Pg.2465]    [Pg.2465]    [Pg.459]    [Pg.809]    [Pg.310]    [Pg.1311]    [Pg.139]    [Pg.175]    [Pg.293]    [Pg.263]    [Pg.151]    [Pg.152]    [Pg.154]    [Pg.542]    [Pg.187]    [Pg.292]    [Pg.473]    [Pg.483]    [Pg.492]    [Pg.65]    [Pg.7]    [Pg.152]    [Pg.103]    [Pg.104]    [Pg.159]    [Pg.161]    [Pg.189]    [Pg.237]    [Pg.246]   