Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Inhabited building

Note 7 "Inhabited Building means a building regularly occupied in whole or in part as a habitation for human beings or any church, schoolhouse, railroad station, store, or other structures where people are accustomed to assemble, except any building or structure occupied in connection with the manufacture, transportation, storage or use of explosives. Note 8—"Railway means any steam, electric, or other railroad or railway which carries passengers for hire. [Pg.785]

Barricades in Explosives and Ammunition Instal lotions. Barricades are required for protection of inhabited buildings, factories, magazines, railroads, highways, bridges, etc from explosions in installations in which expls or ammunitions are manufd, handled or stored. A barricade can be either natural such as a hill or timber of sufficient density) or artificial(s ich as a sand- or earth-filled embankment with a min width of 3ft... [Pg.22]

Ingolin = concentrated hydrogen peroxide (german) 23 inhabited building 138 inhibited propellant 191 305 Initialsprengstoffe = initiating explosives 135 191 initiation 191 initiator 94 191 injector nitration 227... [Pg.30]

In order to estimate the safe distance required for an amount M of the explosive, it may be assumed that this distance increases with the cube root of M we thus have f Ym. This law is explained on p. 83 of this book if M is given in kg, and the safe distance is to be obtained in meters, then f is about 16 for the distance to inhabited buildings, about 8 for the distance between dangerous and safe areas of the explosivemanufacturing plant, and about 1.5 for the distance between one storehouse and another. [Pg.192]

It is common in the explosive industry to be separated by either "barricaded or inbarricaded intraline distance" (corresponding to blast loadings of 10 and 3.,5 psi respectively) or "inhabited building distance" (corresponding to blast loading of 1.2 psi). These distances are published in the DARCOM Safety Manual (DRCR 385-100) based upon proven scaling laws. [Pg.17]

Based upon results obtained it was shown that the use of preengineered buildings to provide protection at over-pressure ranges corresponding to inhabited building distances = 1.2 psi) is... [Pg.19]

Quantity-distances established to keep overpressure below window breakage level for inhabited buildings. [Pg.135]

The public access exclusion distance (PAED) provides protection analogous to the inhabited-building distance for explosives. The hazard PAED zone calculated from the MCE shall represent that arc from the agent source containing no more than 10.0, 4.3, and 150,0 mg-min/m of GB, VX, or HD, respectively. Positive means shall be taken to assure that no persons, not directly associated with chemical weapons operations, enter areas so defined. [Pg.239]

Over Not Over Inhabited Building Public Traffic Route Separation between Magazines (6W )... [Pg.242]

Quantity of Explosives (lb) Minimum Distance between Magazines Distance from Inhabited Building Distance from Public Highway Distance from Passenger Railways and High Traffic Highways ... [Pg.255]

Inhabited Building Distances, For the time being, the NATO safety criteria concerning debris is still one piece of hazardous debris per 56 or 0.018 per m. Based on this value, the respective scaled distance can be derived from Fig. 26.30. The graph and the formula... [Pg.606]

The inhabited building distance (IBD), or any other distance has to be measured as a horizontal distance from the crater center at the bottom of the crater (at the level of the installation). [Pg.607]

Fig. 7. Variation in distance to unbarricaded inhabited buildings with mass M for Class 950 materials variation in i/, 2 with mass M of liquid hydrogen. Fig. 7. Variation in distance to unbarricaded inhabited buildings with mass M for Class 950 materials variation in i/, 2 with mass M of liquid hydrogen.

See other pages where Inhabited building is mentioned: [Pg.146]    [Pg.290]    [Pg.366]    [Pg.432]    [Pg.418]    [Pg.785]    [Pg.405]    [Pg.185]    [Pg.16]    [Pg.16]    [Pg.191]    [Pg.290]    [Pg.366]    [Pg.418]    [Pg.785]    [Pg.785]    [Pg.434]    [Pg.801]    [Pg.801]    [Pg.134]    [Pg.406]    [Pg.224]    [Pg.84]    [Pg.133]    [Pg.9]    [Pg.262]    [Pg.570]    [Pg.586]    [Pg.590]    [Pg.607]    [Pg.193]   
See also in sourсe #XX -- [ Pg.7 ]

See also in sourсe #XX -- [ Pg.136 ]




SEARCH



Distance inhabited building

© 2024 chempedia.info