Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Incipient measurements

This point was taken up by Reynolds in a letter addressed to G. G. Stokes, in the latter s capacity as Secretary of the Royal Society [83]. Reynolds pointed out that Maxwell s theory evaluated the effects of thermal transpiration only in circumstances where they were too small to be measured, and complained that Maxwell had misrepresented his own theoretical treat ment of the phenomenon. However, this incipient controversy never developed... [Pg.181]

The immersion of glass electrodes in strongly dehydrating media should be avoided. If the electrode is used in solvents of low water activity, frequent conditioning in water is advisable, as dehydration of the gel layer of the surface causes a progressive alteration in the electrode potential with a consequent drift of the measured pH. Slow dissolution of the pH-sensitive membrane is unavoidable, and it eventually leads to mechanical failure. Standardization of the electrode with two buffer solutions is the best means of early detection of incipient electrode failure. [Pg.466]

In the numerical calculations, an elastic-perfectly-plastic ductile rod stretching at a uniform strain rate of e = lO s was treated. A flow stress of 100 MPa and a density of 2700 kg/m were assumed. A one-millimeter square cross section and a fracture energy of = 0.02 J were used. These properties are consistent with the measured behavior of soft aluminim in experimental expanding ring studies of Grady and Benson (1983). Incipient fractures were introduced into the rod randomly in both position and time. Fractures grow... [Pg.299]

This result was checked by simulation of both CSTR measurements and calculations of tubular reactor incipient runaways. It should be noted that the predicted AT at inflection from CSTR experiments agrees well with measures in tubular simulation. At hotspot the AT to the AT at inflection is between 1.4 and 1.8. Using a multiplier of 1.4 as recommended by Nelson (1974) is safe. [Pg.203]

This section discusses normal failure modes, monitoring techniques that can prevent premature failures, and the measurement points required for monitoring common machine-train components. Understanding the specific location and orientation of each measurement point is critical to diagnosing incipient problems. [Pg.701]

The frequency-domain, or TFT, signature acquired at each measurement point is an actual representation of the individual machine-train component s motion at that point on the machine. Without knowing the specific location and orientation, it is difficult - if not impossible - to correctly identify incipient problems. In simple terms, the TFT signature is a photograph of the mechanical motion of a machine-train in a specific direction and at a specific point and time. [Pg.701]

Key measurement point locations and orientation to the machine s shaft were selected as part of the database setup to provide the best possible detection of incipient machine-train problems. Deviation from the exact point or orientation will affect the accuracy of acquired data. Therefore, it is important that every measurement throughout the life of the program be acquired at exactly the same point and orientation. In addition, the compressive load or downward force applied to the transducer should also be the same for each measurement. [Pg.812]

Ostergaard (02) measured the wall-to-bed heat-transfer coefficient in a bed of 3-in. diameter. The media were air, water, and glass ballotini of0.5-mm diameter. It was observed that the heat-transfer coefficient for a liquid fluidized bed near the point of incipient fluidization could be approximately... [Pg.128]

Qu W, Mudawar 1 (2002a) Experimental and numerical study of pressure drop and heat transfer in a single-phase micro-channel heat sink. Int J Heat Mass Transfer 45 2549-2565 Qu W, Mudawar 1 (2004) Measurement and correlation of critical heat flux in two-phase micro-channel heat sinks. Int J Heat Mass Transfer 47 2045-2059 Qu W, Mudawar 1 (2002b) Prediction and measurement of incipient boiUng heat flux in micro-channel heat sinks. Int J Heat Mass Transfer 45 3933-3945... [Pg.96]

The point of ONB located at the channel exit corresponds to minimum heat flux at which the boiling incipience is possible for the channel of the given length. Kennedy et al. (2000) presented the measurements that were carried out at different values of the inlet average velocity t/m, whereas the inlet temperature Tin, was constant. [Pg.271]

Figure 5b. Variation in the magnetic properties of metal clusters are investigated by measuring the depletion of a highly collimated cluster beam by an inhomogeneous magnetic field. Fe clusters and their oxides (FexO and Fex02) at several applied fields. The uniform depletion of Fe clusters indicates that their magnetic moments increase approximately linearly with number of atoms, as would be anticipated for incipient ferromagnetic iron. Unexpected, however, is the much larger depletion of iron oxide clusters. Figure 5b. Variation in the magnetic properties of metal clusters are investigated by measuring the depletion of a highly collimated cluster beam by an inhomogeneous magnetic field. Fe clusters and their oxides (FexO and Fex02) at several applied fields. The uniform depletion of Fe clusters indicates that their magnetic moments increase approximately linearly with number of atoms, as would be anticipated for incipient ferromagnetic iron. Unexpected, however, is the much larger depletion of iron oxide clusters.
Catalysts were prepared on various supports. One example was a Calgon 120% CTC coconut carbon. The impregnation volume of metal solution was calculated using the measured incipient wetness of the support 0.85 cc liquid per gram of carbon for the... [Pg.304]

In principle, all elements can be determined by AAS, since the atoms of any element can be excited and are therefore capable of absorption. The limitations lie practically only in the field of instrumentation. Measurements below 200 mn in the vacuum UV range are difficult, owing to the incipient absorption of atmospheric oxygen. With modified instruments and a shielded flame or a graphite furnace, it is possible to determine such elements as iodine at 183.0 nm, sulfur at 180.7 nm, and phosphorous at 177.5 nm, 178.3 nm and 178.8 nm. [Pg.608]

There are numerous experimental complications in the measurement of solubility. Solid phases, formed incipiently, are often metastable with respect to a... [Pg.99]

Hall and drift mobilities have been measured in mixtures of n-pentane and NP by Itoh et al., (1991) between 20 and 150°C. They found both mobilities to decrease with the addition of n-pentane to the extent that the Hall mobility in a 30% solution was reduced by a factor of about 5 relative to pure NR However the Hall ratio remained in the range 0.9 to 1.5. This indicates that, up to 30% n-pentane solution in NP, the incipient traps are not strong enough to bind an electron permanently. However, they are effective in providing additional scattering mechanism for electrons in the conducting state. [Pg.326]

PVA and TaM -for the 88%-hydrolyzed PVA. The same dependence was found for the adsorbed layer thickness measured by viscosity and photon correlation spectroscopy. Extension of the adsorption isotherms to higher concentrations gave a second rise in surface concentration, which was attributed to multilayer adsorption and incipient phase separation at the interface. The latex particle size had no effect on the adsorption density however, the thickness of the adsorbed layer increased with increasing particle size, which was attributed to changes in the configuration of the adsorbed polymer molecules. The electrolyte stability of the bare and PVA-covered particles showed that the bare particles coagulated in the primary minimum and the PVA-covered particles flocculated in the secondary minimum and the larger particles were less stable than the smaller particles. [Pg.77]


See other pages where Incipient measurements is mentioned: [Pg.178]    [Pg.204]    [Pg.236]    [Pg.237]    [Pg.538]    [Pg.2576]    [Pg.8]    [Pg.366]    [Pg.83]    [Pg.212]    [Pg.125]    [Pg.265]    [Pg.278]    [Pg.289]    [Pg.317]    [Pg.4]    [Pg.58]    [Pg.444]    [Pg.220]    [Pg.65]    [Pg.116]    [Pg.286]    [Pg.46]    [Pg.47]    [Pg.47]    [Pg.190]    [Pg.282]    [Pg.286]    [Pg.280]    [Pg.279]    [Pg.777]    [Pg.414]    [Pg.252]    [Pg.84]   
See also in sourсe #XX -- [ Pg.419 ]




SEARCH



© 2024 chempedia.info