Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

HPLC high performance liquid reverse-phase

Figure 6-2 Chromatogram from an HPLC reversed-phase separation of tricyclic antidepressants with the use of a UV photometer detector set at 2l5nm. Signal is displayed at 0.1 AUFS, HPLC high-performance liquid chromatography UV, ultraviolet AUFS, absorbance units full scale. (Courtesy Vydac/The Separations Group, Hesperia, Calif.)... Figure 6-2 Chromatogram from an HPLC reversed-phase separation of tricyclic antidepressants with the use of a UV photometer detector set at 2l5nm. Signal is displayed at 0.1 AUFS, HPLC high-performance liquid chromatography UV, ultraviolet AUFS, absorbance units full scale. (Courtesy Vydac/The Separations Group, Hesperia, Calif.)...
Most common furanocoumarins have characteristic retention properties on HPLC (High Performance Liquid Chromatography) with both reversed-phase and conventional-phase columns (Spencer et al., 1987). The assignment of ring-substitution patterns of plant-derived furanocoumarins can be made by negative-ion mass spectrometry (Plattner and Spencer, 1988). [Pg.133]

As a method of research, has been used high-performance liquid chromatography in reversed - phase regime (RP HPLC). The advantage of the present method is the following the additional information about AIST and FAS composition (homologous distribution) simple preparation of samples (dilution of a CS sample of in a mobile phase). [Pg.133]

The aim of the work is investigate possibilities of application of Cartridges Packed DIAPAK for concentrating antibiotics Cefazoline and Levomycetine and analyze them by Reversed Phase High Performance Liquid Chromatography (RP HPLC). [Pg.382]

In 1979, it was stated that poiybrominated aromatic ethers have received little attention (ref. 1). That statement is still applicable. Analyses to characterize this class of commercial flame retardants have been performed using UV (refs. 1-2), GC (refs. 1-6), and GC-MS (refs. 1-4). The bromine content of observed peaks was measured by GC-MS, but no identification could be made. The composition of poiybrominated (PB) diphenyl ether (DPE) was predicted from the expected relationship with polyhalogenated biphenyl, a class which has received extensive attention. NMR (refs. 3-6) was successfully used to identify relatively pure material which had six, or fewer, bromine atoms per molecule. A high performance liquid chromatography (HPLC) method described (ref. 1) was not as successful as GC. A reversed phase (RP) HPLC method was mentioned, but no further work was published. [Pg.399]

Reversed-phase Cig chromatography column. Keystone Scientific Betasil, 100 x 2.0-mm i.d., 5-pm particle size, 100 A, Part No. 105-701-2-CPF TSQ 7000 LC/MS/MS system with electrospray ionization (ESI) or atmospheric pressure chemical ionization (APCI) interface and gradient high-performance liquid chromatography (HPLC) unit, or equivalent Vacuum manifold for use with SPE cartridges (Varian Vac Elut 10 or equivalent)... [Pg.491]

Reversed-phase high-performance liquid chromatography (HPLC) column 50 mm x 3.2-mm i.d. with Kromasil 5- um Gig packing High-performance liquid chromatograph coupled to a triple-quadrupole mass spectrometer with an atmospheric pressure chemical ionization (APCI) source Gel permeation chromatograph with a 60 mm x 25-mm i.d. column packed with Bio-Beads SX-3 (50-g)... [Pg.1169]

Procedure Flavonoids are then further purified with 2 ml of methanolic HC1 (2 N), followed by centrifugation (2 min, 15 600 g), hydrolyzation of 150 il of suspension in an autoclave (15 min, 120 C). A reverse osmosis-Millipore UF Plus water purification system is used in high performance liquid chromatography (HPLC) with an autosampler. After injections of 5 pg of samples, the mobile phases flow at a rate of 1 ml/minute with isocratic elution in a column at 30 C. [Pg.213]


See other pages where HPLC high performance liquid reverse-phase is mentioned: [Pg.18]    [Pg.500]    [Pg.177]    [Pg.49]    [Pg.139]    [Pg.324]    [Pg.348]    [Pg.369]    [Pg.527]    [Pg.3182]    [Pg.1809]    [Pg.50]    [Pg.72]    [Pg.14]    [Pg.107]    [Pg.454]    [Pg.33]    [Pg.34]    [Pg.502]    [Pg.157]    [Pg.436]    [Pg.493]    [Pg.223]    [Pg.223]    [Pg.262]    [Pg.323]    [Pg.607]    [Pg.904]    [Pg.1146]    [Pg.1146]    [Pg.142]    [Pg.704]    [Pg.16]    [Pg.127]    [Pg.192]    [Pg.250]    [Pg.33]    [Pg.187]   
See also in sourсe #XX -- [ Pg.250 ]




SEARCH



HPLC, High performance

HPLC, High performance reverse-phase

High phases

High reverse-phase

Liquid HPLC)

Reverse-phase HPLC

Reverse-phase high-performance liquid

Reverse-phase liquid

Reversed-phase HPLC

Reversed-phase high-performance

Reversed-phase high-performance liquid

Reversed-phase liquid

© 2024 chempedia.info