Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

High performance liquid integration

High-performance liquid chromatograph Model LC-lOA (Shimadzu Co., Japan) Integrator Chromatopac Model C-R7A (Shimadzu Co., Japan)... [Pg.1337]

Racaityte, K., Lutz, E.S.M., Unger, K.K., Lubda, D., Boos, K.S. (2000). Analysis of neuropeptide Y and its metabolites by high-performance liquid chromatography—electrospray ionization mass spectrometry and integrated sample cleanup with a novel restricted-access sulphonic acid cation exchanger. J. Chromatogr. A 890, 135-144. [Pg.219]

M. A. Strege High-performance liquid chromatographic-electrospray ionization mass spectrometric analyses for the integration of natural products with modem high-... [Pg.213]

Often, treatment of samples with fluorescence labeling agent reacts with primary and secondary amines to give a fluorescent compound. This is especially important for detecting amino acids in protein hydrolyzates. Fluorescence detectors may also be integrated into a high performance liquid chromatographic (HPLC) system. [Pg.156]

In 1993, the incidence of antimicrobials in car tanker milk and the suitability of different tests for the detection of antimicrobials on the MRL level has been examined in Northern Germany using an integrated detection system (14). This system comprised microbial inhibitor tests for screening, immunochemical tests for preliminary confirmation, and high-performance liquid chromatography (HPLC) for final confirmation either in a parallel or a subsequent fashion in case of positive or questionable screening results. [Pg.465]

High-performance liquid chromatograph (HPLC e.g., Waters Chromatography) equipped with column heater, solvent pump, UV detector (set at 210 nm), integrator, autosampler, and (for manual injection) a 10-pl sample loop 15 x 0.46-cm YMC-ODS-AQ analytical column (AQ12S031546WT, Waters Chromatography)... [Pg.1120]

CO Dasenbrock, WR Lacourse. Assay for cephapirin and ampicillin in raw milk by high-performance liquid chromatography-integrated pulsed amperometric detection. Anal Chem 70 2415-2420,1998. [Pg.685]

Figure 5.2 The integration of high-performance liquid chromatography and two mass spectrometers to form the LC/MS/MS instrument. The integrated bench-scale steps are shown at the top. (Courtesy of Milestone Development Services, Newtown, Pa., USA.)... Figure 5.2 The integration of high-performance liquid chromatography and two mass spectrometers to form the LC/MS/MS instrument. The integrated bench-scale steps are shown at the top. (Courtesy of Milestone Development Services, Newtown, Pa., USA.)...
The use of high performance liquid chromatography (HPLC) on-line or off-line is an essential feature for peptide mapping to integrate the removal of buffers and salts (purification) and the separation of analytes (preconcentration) with mass spectrometry. With on-line LC/MS approaches, low flow rates (<100pL/min) have been demonstrated to provide maximum sensitivity with ESI techniques for the analysis of proteins. In the work performed by Arnott and... [Pg.73]

Zhao, Y.-Y., S. Hrudey, and X.-F. Li. 2006. Determination of microcystins in water using integrated sobd-phase microextraction with microbore high-performance liquid chromatography-electrospray quadruple time-of-flight mass spectrometry../. Chromatogr. Sci. 44 359-365. [Pg.470]

The end products of acid and enzymatic hydrolysis of corncob and sugarcane bagasse were analyzed by using a high-performance liquid chromatograph (Waters, Milford, MA) equipped with a Rheodyne automatic injector with a 20- iL injection capacity loop, a Shodex Sugar SC 1011 column, and an integrator model 747 with a model 410 RI detector. The mobile phase was deionized water, and the flow rate was adjusted to 0.8 mL/min. [Pg.1007]

Equipment and expertise. Synthesis requires dedicated laboratory space and equipment. Protein synthesis is best done with the aid of a peptide synthesizer which is capable of optimal step-wise yields. Purification using reverse-phase high-performance liquid chromatography (RP-HPLC) is an integral part of the procedure (16), so at least one preparative and one analytical HPLC systems is needed. Access to electrospray mass spectrometry is essential. [Pg.48]

Based on the quantity of data and the complexity of the process, an enterprise operational informatics system must be robust and scalable. It should also integrate with analytical instrumentation such as high performance liquid chromatography (HPLC) MS to verify compound identity. A recent review of HTS informatics provides a compact overview of the key informatics elements of HTS operations and data handling (Ling, 2008). [Pg.235]


See other pages where High performance liquid integration is mentioned: [Pg.30]    [Pg.122]    [Pg.297]    [Pg.608]    [Pg.379]    [Pg.273]    [Pg.239]    [Pg.551]    [Pg.102]    [Pg.452]    [Pg.402]    [Pg.2]    [Pg.47]    [Pg.166]    [Pg.105]    [Pg.456]    [Pg.148]    [Pg.78]    [Pg.76]    [Pg.633]    [Pg.186]    [Pg.228]    [Pg.252]    [Pg.125]    [Pg.406]    [Pg.642]    [Pg.429]    [Pg.266]    [Pg.200]    [Pg.324]    [Pg.497]    [Pg.36]    [Pg.315]    [Pg.270]    [Pg.92]    [Pg.98]   
See also in sourсe #XX -- [ Pg.5 , Pg.53 ]




SEARCH



Integrative performance

Liquid integrity

© 2024 chempedia.info