AH columns, distributors, and ancHlary hardware such as piping, valves, and pumps must be constmcted of corrosion-resistant materials, or coated with an appropriate substance. AH streams that contact the hardware during each step of the cycHc operation need to be considered in this selection. [Pg.381]

The Purpose/Description/Requirements column of the table is provided only as a first indicator of some of the application s capabilities and to assist with modifying criteria that could eliminate the system from further review (e.g., hardware requirements). [Pg.280]

Many researchers choose to buy expensive GPC/SEC columns from one of the major producers because that producer s columns had been used in the past or because of a successful marketing campaign by one particular producer. It should be noted that repacked columns can be obtained for a fraction of the cost of new columns. American Polymer Standards repacked columns are guaranteed to perform just as well as new columns from any company. When a column is repacked the only parts reused are the stainless-steel tube and end caps. This hardware is then repacked using new frits and new ST-DVB gel. Each column is individually tested in a quality control laboratory and shipped in the customer s choice of solvent. American Polymer Standards offers a column repacking service because it is a practical, inexpensive way for customers to acquire state of the art GPC/SEC columns. [Pg.160]

Moreover, polymer applications determine a number of important column (hardware) design properties to get reproducible results and the most efficient separations. Most of them are related to the polymer conformation in the injection band moving through the column. [Pg.269]

PSS has developed proprietary packing procedures for its sorbents, that allow a homogeneous filling of the column hardware with no change in particle properties. This thoroughness in the packing procedure is reflected in the superior performance of PSS SEC columns and their long life, even in difficult conditions. [Pg.289]

Polymer Laboratories employs their own individual design of column hardware, which was developed to give low dispersion, high-performance SEC columns. The components used in the design are specified to very low tolerances dimen-... [Pg.363]

Table 3.7 list,s the critical density and type of process for several von Neumann and Moore neighborhood rules. In the first and fourth columns, the rules are defined by the fractions (m/n), which specify a threshold of rn cr = 1 sites out of a total of n possible votes. The table entries for are taken from published results [vich84j using the CAM-6 hardware simulator [marg87] whether some or all of these values can be determined analytically remains an open problem. [Pg.128]

Mobile phase flow rates from nlmin to in excess of 1 mlmin can be used with appropriate hardware, thus allowing conventional and microbore columns to be employed. [Pg.179]

Tne derivation of eq 10 was undertaken with the assumption that the sample effluent was monodisperse in molecular weight at any V. In reality this is never the case. First, if the frequency of branching varies with molecular weight, species of different molecular weight (but equivalent hydrodynamic volume) may elute at the same V (1 ). Second, molecular weight polydispersity at V results from assorted hardware mixing volumes and band-spreading of the SEC columns 0,11). [Pg.110]

Operating when possible in low pressure conditions to minimize equipment and column hardware costs... [Pg.115]

Validations fall into two types prospective and retrospective. In prospective validation (see flow chart in Figure 2) the validation is done in a sequential manner, involving installation qualification and operational qualification (IQ/OQ) of equipment (e.g., chromatography instrumentation or column hardware). Appropriate calibrations accompany the IQ/OQ. Process qualification, or PQ, involves formal review and approval of a PQ protocol, execution of this protocol, and issuance of a formal PQ report which includes data analysis and recommendations (i.e., approval/certification of the process). If the process is not approved, the report may recommend a redesign or redoing of the validation protocol and, in some cases, a return of the process to process development for further optimization. [Pg.118]

Column modification Cost of modification (multiply factor by cost of new hardware)... [Pg.23]

Topics which will be presented in this chapter include the hardware, software, automation, valve and column configurations, and integration used in comprehensive 2DLC. Aspects of the 2DLC experiment in conjunction with multichannel detectors such as UV diode array optical detectors and mass spectrometers are discussed along with the handling of the data, which is expected to expand in scope in the future as chemometric methods are more widely used for data analysis. [Pg.97]


See other pages where Column hardware is mentioned: [Pg.54]    [Pg.54]    [Pg.66]    [Pg.94]    [Pg.352]    [Pg.111]    [Pg.1549]    [Pg.1556]    [Pg.94]    [Pg.160]    [Pg.168]    [Pg.269]    [Pg.310]    [Pg.363]    [Pg.617]    [Pg.223]    [Pg.243]    [Pg.23]    [Pg.110]    [Pg.428]    [Pg.828]    [Pg.537]    [Pg.605]    [Pg.108]    [Pg.109]    [Pg.111]    [Pg.115]    [Pg.124]    [Pg.201]    [Pg.262]    [Pg.225]    [Pg.61]    [Pg.67]    [Pg.101]    [Pg.133]    [Pg.252]    [Pg.257]    [Pg.343]   