Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Glass high-resistance

AU ground glass joints should be constructed of a high resistance glass, such as Pyrex. The most common form is shown in Fig. II, 55, 1, and this is the type largely encountered in practice. Fig. II, 55, 2 is... [Pg.210]

Electrical. Glasses are used in the electrical and electronic industries as insulators, lamp envelopes, cathode ray tubes, and encapsulators and protectors for microcircuit components, etc. Besides their abiUty to seal to metals and other glasses and to hold a vacuum and resist chemical attack, their electrical properties can be tailored to meet a wide range of needs. Generally, a glass has a high electrical resistivity, a high resistance to dielectric breakdown, and a low power factor and dielectric loss. [Pg.299]

In addition, molybdenum has high resistance to a number of alloys of these metals and also to copper, gold, and silver. Among the molten metals that severely attack molybdenum are tin (at 1000°C), aluminum, nickel, iron, and cobalt. Molybdenum has moderately good resistance to molten zinc, but a molybdenum—30% tungsten alloy is practically completely resistant to molten zinc at temperatures up to 800°C. Molybdenum metal is substantially resistant to many types of molten glass and to most nonferrous slags. It is also resistant to hquid sulfur up to 440°C. [Pg.465]

Materials of Construction. Glass has excellent corrosion-resistance to wet or dry bromine. Lead is very usefiil for bromine service if water is less than 70 ppm. The bromine corrosion rate increases with concentrations of water and organics. Tantalum and niobium have excellent corrosion-resistance to wet or dry bromine. Nickel has usefiil resistance for dry bromine but is rapidly attacked by wet bromine. The fluoropolymers Kynar, Halar, and Teflon are highly resistant to bromine but are somewhat permeable. The rate depends on temperature, pressure, and stmcture (density) of fluoropolymer (63). [Pg.288]

Owing to the high resistance of the glass membrane, a simple potentiometer cannot be employed for measuring the cell e.m.f. and specialised instrumentation (Section 15.14) must be used. The e.m.f. of the cell may be expressed by the equation ... [Pg.556]

The patch-clamp technique is based on the formation of a high resistance seal (109-10lon) between the tip of a glass micropipette and the cell membrane it touches (gigaohm-seal). This technique allows recordings of ionic currents through single ion channels in the intact cell membrane and in isolated membrane patches at a... [Pg.935]

Compared with tar, which has a relatively short lifetime in the marine environment, the residence times of plastic, glass and non-corrodible metallic debris are indefinite. Most plastic articles are fabricated from polyethylene, polystyrene or polyvinyl chloride. With molecular weights ranging to over 500,000, the only chemical reactivity of these polymers is derived from any residual unsaturation and, therefore, they are essentially inert chemically and photochemically. Further, since indigenous microflora lack the enzyme systems necessary to degrade most of these polymers, articles manufactured from them are highly resistant or virtually immune to biodegradation. That is, the properties that render plastics so durable... [Pg.235]

Apart from the necessity of excluding interferences from any diffusion potential, normal potentiometry requires accurate determination of the emf, i.e., without any perceptible drawing off of current from the cell therefore, usually one uses the so-called Poggendorff method for exact compensation measurement the later application of high-resistance glass and other membrane electrodes has led to the modern commercial high-impedance pH and PI meters with high amplification in order to detect the emf null point in the balanced system. [Pg.45]

Glass electrode [see Fig 2.10 (1)J. The pH glass electrode, as the most important representative of the glass electrodes, will be the first subject to be treated, and especially in its application to aqueous solutions. Attached to the stem of high-resistance glass, the electrode proper consists of a pH-sensitive glass bulb that acts as a membrane between an inner reference electrolyte and an outer... [Pg.73]

H = High resistance non-responsive glass, and I = H+-selective glass membrane. [Pg.245]

The sensitivity of instruments using low resistance circuits is determined primarily by the sensitivity of the galvanometer (Figure 4.5). Electrode systems that have a high resistance, e.g. glass electrodes, require a high impedance voltmeter, which converts the potential generated into current which can be amplified and measured. Such instruments are commonly known as pH meters but may be used for many potentiometric measurements other than pH. [Pg.172]

The reference electrode is connected with the cell via a glass tube (Luggin capillary) filled with electrolyte, and the narrowed orifice of the tube is placed about 0.1 to 0.3 mm in front of the side of the working electrode that faces the counter electrode. The potential between this point and the surface of the working electrode is measured with a high resistance voltmeter that makes contact with the silver wire of... [Pg.86]


See other pages where Glass high-resistance is mentioned: [Pg.150]    [Pg.110]    [Pg.405]    [Pg.288]    [Pg.320]    [Pg.323]    [Pg.335]    [Pg.335]    [Pg.466]    [Pg.467]    [Pg.328]    [Pg.975]    [Pg.2452]    [Pg.278]    [Pg.143]    [Pg.35]    [Pg.699]    [Pg.871]    [Pg.890]    [Pg.495]    [Pg.565]    [Pg.658]    [Pg.129]    [Pg.7]    [Pg.13]    [Pg.36]    [Pg.74]    [Pg.76]    [Pg.572]    [Pg.340]    [Pg.4]    [Pg.313]    [Pg.169]    [Pg.302]    [Pg.262]    [Pg.636]    [Pg.244]    [Pg.150]   
See also in sourсe #XX -- [ Pg.120 ]




SEARCH



Resistive Glass

© 2024 chempedia.info