Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Generators, location

Establish a monitoring program to run alongside the waste reduction plan to facilitate measurement of actual improvements Establish an internal waste charging system (cost centres at each waste-generating location)... [Pg.10]

Levitation is a stable condition in which a particle responds to the oscillating fluid in such a way that the influence of finite buoyancy, or gravity, forces is completely neutralized so that the particle oscillates about a fixed position (Houghton, 1963, 1964, 1966, 1968 Krantz, Carley and Al-taweel, 1973 Tunstall and Houghton, 1968 Van Oeveren and Houghton, 1971). Figure 37 (Liu, 1983) shows the levitation of solid particles in air under oscillation caused by a sonic generator located at the bottom of the column. [Pg.547]

Modem switchboard circuit breakers are often able to clear a major fault current within 120 milliseconds, which is typically five or six cycles of the fundamental current. When these circuit breakers are used with generators, and switchboards that are fed by generators located only a short distance away, the decay of the sub-transient current merges with the decay of the transient current. Even at 120 milliseconds the current may have a substantial value. There are several ways of assessing the breaking duty current. [Pg.291]

Solar One - A solar thermal electric central reciever power plant ("power tower") located in Barstow, California, and completed in 1981. The Solar One had a design capacity of 10,000 peak kilowatts, and was composed of a receiver located on the top of a tower surrounded by a field of reflectors. The concentrated sunlight created steam to drive a steam turbine and electric generator located on the ground. [Pg.413]

Fig. 3.5 Entropy generation Locations where entropy was generated are generally noticeable by increased temperature. Fig. 3.5 Entropy generation Locations where entropy was generated are generally noticeable by increased temperature.
The introduction of a micro-source within an existing power system assumes that there may be a cluster of small generators located in electrical proximity, interconnected through on-site feeders and operation can be isolated or connected to a distribution grid. [Pg.195]

The 1255 MW(th)/400 MW(e) Consolidated Nuclear Steam System (CNSS) is an integral pressurized-water reactor (PWR) with the reactor core and steam generators located within the reactor pressure vessel (see Figure 1). Reactor coolant system pressure Is controlled via an electrically heated pressurizer connected to the reactor vessel through four surge lines. [Pg.156]

Many biomedical devices work inside the human body. Pacemakers, artificial heart valves, stents, and even artihcial hearts are some of the bionic devices correcting problems with the cardiovascular system. Pacemakers generate electric signals that improve abnormal heart rates and abnormal heart rhythms. When pulse generators located in the pacemakers sense an abnormal heart rate or rhythm, they produce shocks to restore the normal rate. Stents are inserted into an artery to widen it and open clogged blood vessels. Stents and pacemakers are examples of specialized bionic devices made up of bionic materials compatible with human structure and function. [Pg.230]

One of the first references to heat pipes in chanical reactors (they had been used in nuclear reactors), was in a methanation plant (Biery, 1977). Heat pipes were inserted next to rows of cylindrical ceramic catalyst columns, so that they took heat from hot spots on the catalyst. The vertical heat pipes then transferred the heat to a steam generator, located in the top of the reactor vessel. The steam was recovered for process use. [Pg.174]

Advanced materials for long-term maintenance of steam generator located inside the reactor vessel. [Pg.753]

The turbine generator system is shown in Fig. XXVI-9, Standard Rankine cycle with a single feedwater reheater is used for generation / co-generation of electricity. The pressure of steam-water coolant in the secondary circuit is 7 MPa. Steam from the steam generator located inside the reactor vessel is directed to the turbine to produce electricity and can also be directed to a desalination plant for the production of potable water. Steam from the turbine is condensed to water by using seawater as an ultimate heat sink in normal operation. The water from the condenser is mixed with the feedwater to be pumped to the SG inlet through an orifice block. [Pg.757]


See other pages where Generators, location is mentioned: [Pg.1119]    [Pg.451]    [Pg.1200]    [Pg.1203]    [Pg.1204]    [Pg.472]    [Pg.336]    [Pg.134]    [Pg.25]    [Pg.451]    [Pg.51]    [Pg.147]    [Pg.343]    [Pg.942]    [Pg.167]    [Pg.111]    [Pg.1288]    [Pg.99]    [Pg.1289]    [Pg.345]    [Pg.1123]    [Pg.92]    [Pg.287]    [Pg.56]    [Pg.243]    [Pg.381]    [Pg.420]    [Pg.152]    [Pg.622]    [Pg.678]    [Pg.456]    [Pg.707]    [Pg.412]    [Pg.1169]    [Pg.107]    [Pg.115]    [Pg.756]    [Pg.758]    [Pg.1007]    [Pg.381]   
See also in sourсe #XX -- [ Pg.240 ]




SEARCH



© 2024 chempedia.info