Freeze refrigerating system

Absorption Refrigeration Systems Two main absorption systems are used in industrial application lithium bromide-water and ammonia-water. Lithium bromide-water systems are hmited to evaporation temperatures above freezing because water is used as the refrigerant, while the refrigerant in an ammonia-water system is ammonia and consequently it can be applied for the lower-temperature requirements. [Pg.1118]

Artificial ground freezing involves the installation of freezing loops in the ground and a self-confined refrigeration system that pumps coolant around the freezing loop. This method is useful only as a temporary treatment approach because of the high thermal maintenance expense. [Pg.629]

Snowman, J. W. Replacement of conventional refrigeration systems in freeze-drying by liquid nitrogen cooled systems. PDA Asian Symposium, p. 329-345, Tokyo, 1994 Copyright 1994 PDA, Inc. Bethesda, Maryland, USA... [Pg.198]

All freeze separation processes depend on the formation of pure solvent crystals from solution, as described for eutectic systems in Section 15.2.1. which allows single-stage operation. Solid-solution systems, requiring multistage-operation, are not usually economic. Several types of freeze crystallisation processes may be designated according to the kind of refrigeration system used as follows . [Pg.888]

In this the refrigerant vapor is compressed mechanically. Two-stage motor compressors are used mostly in freeze-drying systems. This compressor is installed in a screwed-on housing together with an electric motor. [Pg.192]

The most commonly used absorption-refrigeration system operates with water as the refrigerant and a lithium bromide solution as the absorbent. This system is obviously limited to refrigeration temperatures above the freezing point of water. It is treated in detail by Perry and Green.t For lower temperatures the usual system operates with ammonia as refrigerant and water as the solvent. [Pg.445]

Figure 10-8. Equipment needed for lyophilization or freeze drying small samples, (a) The unit is cooled and evacnated by means of a self-contained refrigeration system and vacuum pump. Sample vessels are inserted into the rubber nozzles and the valve (little white knobs) opened for each nozzle that contains a vessel, (b, c) The units are evacuated by connecting them to a mechanical vacuum pump (connection indicated by arrows) and... [Pg.380]

C Consider ihc freezing of packaged meal in boxes with refrigerated air. How do (a) the temperature of air, (h) the velocity of air, (c) the capacity of the refrigeration system, and (d) the size of the meat boxes affect the freezing lime ... [Pg.297]

Kobayashi, M. Development of new refrigeration system and optimum geometry of the vapor condenser for pharmaceutical freeze dryers proceedings of the 4th International drying symposium, Kyoto, Japan, July 9-12, 1984 Toei, R.R., Mujumdar, A., Eds. 2, 464-471. [Pg.1832]

The EMF measured by a readout device reflects the difference between the temperatures of the measuring junction and the reference junction thus, the temperature at the reference junction must be properly controlled. It is usually maintained at the freezing point of water (0°C) by using an ice bath (Fig. 16.23). The ice bath should be a mixture of crushed ice and pure water in a Dewar flask with considerably more ice than liquid. It can be very accurate but not too convenient in some applications, since frequent replacement of melted ice is required. With a thermoelectric refrigeration system [36], ice can be maintained by cooling the bath of water with thermoelectric cooling elements. [Pg.1192]

Melt crystallisation. Differences of 20-30 °C are typically required between the freezing points of the components to be separated and the bulk of the solution. Note that low temperature requires expensive refrigeration system and operating costs. [Pg.275]

Feed gas for carbon monoxide recovery is pretreated to remove carbon dioxide and water. The gas must be dried to remove all traces of moisture. Both carbon dioxide and water will freeze and heat transfer will be impaired at cryogenic temperatures. The feed gas is also compressed to the pressure required for the partial condensation of carbon monoxide at the temperatures that can be reached with the refrigeration system available. Typically, this is between 350 and 500 psig. The operating temperatures are approximately — 160 F to — 200°F. [Pg.102]

Another common unit used in the United States in air-conditioning and refrigeration systems is ton of refrigeration or cooling. One ton of refngetation represents the capacity of a refri ra-tion system to freeze 2000 lb or 1 ton of liquid water at 32°F into 32°F ice in 24 hours. It is... [Pg.352]


See other pages where Freeze refrigerating system is mentioned: [Pg.508]    [Pg.186]    [Pg.456]    [Pg.185]    [Pg.186]    [Pg.558]    [Pg.508]    [Pg.16]    [Pg.16]    [Pg.79]    [Pg.180]    [Pg.183]    [Pg.280]    [Pg.285]    [Pg.2079]    [Pg.2079]    [Pg.457]    [Pg.303]    [Pg.2894]    [Pg.185]    [Pg.186]    [Pg.149]    [Pg.187]    [Pg.1457]    [Pg.265]    [Pg.267]    [Pg.268]    [Pg.31]    [Pg.53]   
See also in sourсe #XX -- [ Pg.271 ]