Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Flow cross-coupling

The aerodynamic cross-coupling effect has been quantified into equivalent stiffness. For instance, in axial-flow machines... [Pg.209]

Another potential problem is due to rotor instability caused by gas dynamic forces. The frequency of this occurrence is non-synchronous. This has been described as aerodynamic forces set up within an impeller when the rotational axis is not coincident with the geometric axis. The verification of a compressor train requires a test at full pressure and speed. Aerodynamic cross-coupling, the interaction of the rotor mechanically with the gas flow in the compressor, can be predicted. A caution flag should be raised at this point because the full-pressure full-speed tests as normally conducted are not Class IASME performance tests. This means the staging probably is mismatched and can lead to other problems [22], It might also be appropriate to caution the reader this test is expensive. [Pg.413]

Metal-catalyzed cross-couplings are key transformations for carbon-carbon bond formation. The applicability of continuous-flow systems to this important reaction type has been shown by a Heck reaction carried out in a stainless steel microreactor system (Snyder et al. 2005). A solution of phenyliodide 5 and ethyl acrylate 6 was passed through a solid-phase cartridge reactor loaded with 10% palladium on charcoal (Scheme 2). The process was conducted with a residence time of 30 min at 130°C, giving the desired ethyl cinnamate 7 in 95% isolated yield. The batch process resulted in 100% conversion after 30 min at 140°C using a preconditioned catalyst. [Pg.10]

One of the obvious areas where flow chemistry comes into its own is in the arena of catalysed reactions and continuous processing. An excellent example of this is the Suzuki reaction (for recent reviews on the Suzuki Cross-Coupling reaction, see Miura 2004 Beilina et al. 2004 ... [Pg.162]

Cross-Coupling Reactions in Microwave-Flow Mode... [Pg.420]

Salen-like ligands have also been used to complex, and hence immobilize, a number of metals onto polystyrene and silica for use in a variety of cross-coupling reactions. The salen-palladium complex 32 was used in Suzuki reactions (Figure 4.7). The column containing the immobilized catalyst was heated to 1000 C in a water bath and the reagents were recirculated continuously at a flow rate of 6 pi/min for 5 h, resulting in conversions in the range of 65-75% [154],... [Pg.105]

The use of a functionalized silica-supported salen-nickel complex has allowed Kumada cross-couplings to be performed in flow the corresponding polystyrene supported complex was shown to be inferior for a number of reasons. Catalyst 33 (Figure 4.7) with the longer tether was found to be more active than the benzyl ether tether used for catalyst 34. This was postulated to be due to the fact that catalyst 33 resided further away from the silica surface and hence was more available for reaction. Under the conditions used a maximum conversion of 65% was found for the 1 1 reaction of 4-bromoanisole and phenylmagnesium chloride, which was found to be comparable to that obtained in batch mode. However, during the reaction catalyst degradation was observed and the conversion reduced from 60% in the first hour to 30% in the fifth hour of the reaction [155,156]. [Pg.105]

Previously, we considered the case where heat and mass flows are coupled in a reaction diffusion system with heat effects, in which the cross coefficients Zrq. Zqr. and LlS, LSl have vanished (Demirel, 2006). Here, we consider the other three cases. The first involves the stationary state balance equations. In the second case, there is no coupling between the heat flow and chemical reaction with vanishing coefficients Zrq and Zqr. Finally, in the third, there is no coupling between the mass flow and chemical reaction because of vanishing cross-coefficients of ZrS and LSl. The thermodynamically coupled modeling equations for these cases are derived and discussed briefly in the following examples. [Pg.481]

The matrix of the phenomenological coefficients must be positive definite for example, for a two-flow system, we have L0 > 0, Ip >0, and Z/.p Z,pZpo > 0.1,0 shows the influence of substrate availability on oxygen consumption (flow), and Ip is the feedback of the phosphate potential on ATP production (flow). The cross-coupling coefficient Iop shows the phosphate influence on oxygen flow, while Zpo shows the substrate dependency of ATP production. Experiments show that Onsagers s reciprocal relations hold for oxidative phosphorylation, and we have Iop = Zpo. [Pg.582]

For alkenes more difficult to reduce than CO2, such as butadiene (63a), electron transfer from C02 to the alkene may be involved. Cross-coupling of CO2 and 63a in MeCN has been carried out in an undivided flow cell at constant current. Using Et4N salts of formate or oxalate as supporting electrolyte, the anode process is formation of CO2 and H" ", which are both consumed in the cathode process [167]. The outcome (up to 63% total yield) was a mixture of isomers of C5, Cg, and Cjo unsaturated carboxylic acids and diacids. The detailed mechanism is not known, but the products may arise from initial addition of C02 to the unreduced butadiene [167], although electron transfer from C02 to 63a or direct reduction of 63a (present in large excess) cannot be ruled out. Based on the observed influence of experimental parameters on the distribution of the C5, Cg, and C]o acid products, the authors suggest that the reactions take place between adsorbed intermediates [167]. [Pg.840]

More importantly, catalytic transformations such as transfer hydrogenations, Suzuki cross-coupling reactions, the Heck reaction, and the Sonogashira reaction were routinely performed in these PASSflow reactors under continuous flow conditions (Schemes 12-15) [41]. [Pg.224]

No61 T, Kuhn S, Musachio AJ et al (2011) Suzuki-Miyaura cross-coupling reactions in flow multistep synthesis enabled by a microfluidic extraction. Angew Chem Int Ed 50 5943-5946... [Pg.41]

Nagaki A, Kemnoku A, Moriwaki Y et al (2010) Cross-coupling in a flow microreactor. Space integration of lithiation and Murahashi coupling. Angew Chem Int Ed 49 7543-7547... [Pg.45]

Nagaki A, Moriwaki Y, Haraki S et al (2012) Cross-coupling of aryllithiums with aryl and vinyl halides in flow microreactors. Chem Asian J 7 1061-1068... [Pg.45]


See other pages where Flow cross-coupling is mentioned: [Pg.172]    [Pg.172]    [Pg.167]    [Pg.133]    [Pg.479]    [Pg.165]    [Pg.189]    [Pg.123]    [Pg.145]    [Pg.101]    [Pg.479]    [Pg.325]    [Pg.67]    [Pg.167]    [Pg.125]    [Pg.509]    [Pg.171]    [Pg.177]    [Pg.287]    [Pg.413]    [Pg.414]    [Pg.413]    [Pg.414]    [Pg.849]    [Pg.850]    [Pg.624]    [Pg.165]    [Pg.415]    [Pg.4]    [Pg.19]    [Pg.674]    [Pg.87]   
See also in sourсe #XX -- [ Pg.427 , Pg.428 ]




SEARCH



Cross flow

Cross-Coupling in a Flow Microreactor

Flow-coupling

© 2024 chempedia.info