Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Fatigue testing strain-life curve

Exploratory creep tests were performed on tensile specimens of NT-154 silicon nitride at 1300 and 1370 C, These specimens were made from the same lot of the material, designated as CP-serles, used In the cyclic fatigue tests discussed In the last progress report, Creep strain was measured using the laser diffraction strain extensometer described elsewhere,2 Figure 7 shows the creep curves of specimens CP-28 and CP-10 tested at 1300 C under applied stress of 160 and 180 MPa, respectively. Both tests were shutdown Inadvertently due to equipment adjustments. The problems have been corrected since then. Therefore, the results of the tests do not represent the creep life of the specimens. However, there were sufficient data points to delineate the essential features of the creep behavior up to the steady-state phase which was clearly definable. Both curves showed a reversed Inflection at the transition between the primary and secondary creep phases, resulting In forming a bump In the otherwise smooth creep curves. [Pg.366]

Corrosion fatigue tests under a controlled potential have been conducted in the passive region at the rest potential of the duplex alloy (Eq=- 2Q raVsce) d at a more anodic potential ( anod.=+150 mVsc ) for a given strain rate e=10 s . This strain rate has been chosen because it corresponds to the more marked corrosion fatigue life reduction at both applied potentials. The Coffin-Manson curves under such conditions are given in Fig. 5-36. The following features can be observed ... [Pg.235]

The stability and permeability of a mix are not sufficient criteria to reflect how a material will perform under the repeated loads generated by traffic. Therefore, any mix design selection process should include an examination of the material s fatigue resistance. Figure 5 shows the relationship between sulfur content and fatigue life for some SAS mixtures at two strain levels [15]. These tests were run at constant stress in third point flexure. Both curves go through a maximum at a sulfur content of 14 percent. [Pg.164]


See other pages where Fatigue testing strain-life curve is mentioned: [Pg.100]    [Pg.101]    [Pg.679]    [Pg.124]    [Pg.248]    [Pg.42]    [Pg.215]    [Pg.235]    [Pg.840]    [Pg.194]    [Pg.326]    [Pg.22]    [Pg.202]    [Pg.19]    [Pg.111]    [Pg.245]    [Pg.98]    [Pg.250]    [Pg.738]    [Pg.465]    [Pg.127]    [Pg.298]    [Pg.203]    [Pg.216]    [Pg.14]    [Pg.34]    [Pg.257]    [Pg.506]    [Pg.778]    [Pg.324]   


SEARCH



Fatigue curves

Fatigue life

Fatigue testing curve

Fatigue tests

Life test

Strain fatigue

Strain life curve

© 2024 chempedia.info