Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Electrochemical cells conduction

Two major sources of ultrasound are employed, namely ultrasonic baths and ultrasonic immersion hom probes [79, 71]- The fonuer consists of fixed-frequency transducers beneath the exterior of the bath unit filled with water in which the electrochemical cell is then fixed. Alternatively, the metal bath is coated and directly employed as electrochemical cell, but m both cases the results strongly depend on the position and design of the set-up. The ultrasonic horn transducer, on the other hand, is a transducer provided with an electrically conducting tip (often Ti6A14V), which is inuuersed in a three-electrode thenuostatted cell to a depth of 1-2 cm directly facing the electrode surface. [Pg.1942]

The combination of electrochemistry and photochemistry is a fonn of dual-activation process. Evidence for a photochemical effect in addition to an electrochemical one is nonnally seen m the fonn of photocurrent, which is extra current that flows in the presence of light [, 89 and 90]. In photoelectrochemistry, light is absorbed into the electrode (typically a semiconductor) and this can induce changes in the electrode s conduction properties, thus altering its electrochemical activity. Alternatively, the light is absorbed in solution by electroactive molecules or their reduced/oxidized products inducing photochemical reactions or modifications of the electrode reaction. In the latter case electrochemical cells (RDE or chaimel-flow cells) are constmcted to allow irradiation of the electrode area with UV/VIS light to excite species involved in electrochemical processes and thus promote fiirther reactions. [Pg.1945]

The concept of the reversed fuel cell, as shown schematically, consists of two parts. One is the already discussed direct oxidation fuel cell. The other consists of an electrochemical cell consisting of a membrane electrode assembly where the anode comprises Pt/C (or related) catalysts and the cathode, various metal catalysts on carbon. The membrane used is the new proton-conducting PEM-type membrane we developed, which minimizes crossover. [Pg.220]

The electrical conductivity also increases with increasing metal oxide content, due to the high mobility of the metal ions. For example several glass compositions have been used as solid electrolytes in galvanic cells in which other metal ions apart from the alkaline and alkaline earth ions have been incorporated. The electrochemical cell... [Pg.309]

It is now appropriate to apply the above considerations of the operation of a well-defined electrochemical cell to the uniform corrosion of a metal in a solution of high conductivity, and under these circumstances both IR and 7/ so, may be regarded as negligible. Thus E will tend to zero, and Ep will tend to be equal to E (within 1-2 mV)... [Pg.87]

Now let s take a more detailed look into the electrochemical cell. Figure 12-5 shows a cross-section of a cell that uses the same chemical reaction as that depicted in Figure 12-1. The only difference is that the two solutions are connected differently. In Figure 12-1 a tube containing a solution of an electrolyte (such as KNOa) provides a conducting path. In Figure 12-5 the silver nitrate is placed in a porous porcelain cup. Since the silver nitrate and copper sulfate solutions can seep through the porous cup, they provide their own connection to each other. [Pg.206]

An electrolyte may be characterized by resistance / [Qcm], which is defined as the resistance of the solution between two electrodes at a distance of 1 cm and an area of 1 cm2. The reciprocal value is called the specific conductivity at[Q" cm"1] [5], For comparison the values of k for various materials are given in Fig. 2 Here is a wide spread for different electrolyte solutions. The selection of a suitable, high-conductivity electrolyte solution for an electrochemical cell depends on its compatibility with other components, such as the positive and negative electrodes. [Pg.5]

In an electrochemical cell, electrical work is obtained from an oxidation-reduction reaction. For example, consider the process that occurs during the discharge of the lead storage battery (cell). Figure 9.3 shows a schematic drawing of this cell. One of the electrodes (anode)q is Pb metal and the other (cathode) is Pb02 coated on a conducting metal (Pb is usually used). The two electrodes are immersed in an aqueous sulfuric acid solution. [Pg.475]

The determination of Ka requires a measurement using a technique such as electrical conductivity, absorption of light, or, in our case, the emf of an electrochemical cell. When K.x is determined, ArG° is obtained from equation (9.116), and tables giving AtG° must take into account this value. For example, = 1.75 x 10 5 at 298.15 K and A,-G° = 27.15 kj-mol-1 for the reaction1 ... [Pg.489]

The materials to be investigated have to be incorporated into electrochemical cells in such a way as to permit the influx and the reflection of microwaves. The electrodes have to be adjusted to the microwave techniques that will be used for the investigation. Basically three different measurement approaches can be distinguished (Fig. 3). The simplest technique for microwave conductivity studies [Fig. 3(a)] is to place the sample directly at the exit of an ordinary waveguide. This setup has the advantage of being very simple and relatively transparent with respect to the phenomena occurring. Microwave power is reflected from the sample... [Pg.443]

Figure 4a. Electrochemical cells for microwave conductivity measurements. Cell above microwave conduit (1) electrochemical cell (plastic tube, placed on working electrode material), (2) counter-electrode, (3) reference electrode, (4) electrolyte, (5) space charge layer, (6) diffusion layer, (7) contact to working electrode, (8) waveguide. Figure 4a. Electrochemical cells for microwave conductivity measurements. Cell above microwave conduit (1) electrochemical cell (plastic tube, placed on working electrode material), (2) counter-electrode, (3) reference electrode, (4) electrolyte, (5) space charge layer, (6) diffusion layer, (7) contact to working electrode, (8) waveguide.
A classical setup for microwave conductivity measurements is based on the utilization of the waveguides. A simple installation consists of a microwave generator (typically a gun diode) which, when the Ka-band is used, can be operated in the frequency region of 28-40 Gc/s this is protected by an isolator against back-reflections from the rest of the microwave circuit. The microwave power is conducted by an attenuator across a circulator into the microwave conductor branch at the end of which the electrochemical cell is mounted. The microwave power reflected from the electrochemical sample is conducted via the circulator into the microwave detector. It typically consists of a diode that acts as an antenna, receiving the electrical alternating field, rectifying it, and con-... [Pg.446]

Time-resolved microwave conductivity measurements with electrodes in electrochemical cells can conveniently be made with pulsed lasers (e.g., an Nd-YAG laser) using either normal or frequency-doubled radiation. Instead of a lock-in amplifier, a transient recorder is used to detect the pulse-induced microwave reflection. While transient microwave experiments with semiconducting crystals or powders have been performed... [Pg.447]

Electrochemical cells for microwave conductivity measurements, 445 Electrochemical measurements with microwave frequencies, diagrammated, 448, 449 with microwaves, 478 Electrochemical polymerization... [Pg.630]

T.I. Politova, V.A. Sobyanin, and V.D. Belyaev, Ethylene hydrogenation in electrochemical cell with solid proton-conducting electrolyte, Reaction Kinetics and Catalysis Letters 41(2), 321-326 (1990). [Pg.13]

The term electrolyte was first introduced in Section I to refer to the solute. In the discussion of electrochemical cells, the term is commonly used to refer to the ionically conducting medium. [Pg.611]

We can understand the differences in properties between the carbon allotropes by comparing their structures. Graphite consists of planar sheets of sp2 hybridized carbon atoms in a hexagonal network (Fig. 14.29). Electrons are free to move from one carbon atom to another through a delocalized Tr-network formed by the overlap of unhybridized p-orbitals on each carbon atom. This network spreads across the entire plane. Because of the electron delocalization, graphite is a black, lustrous, electrically conducting solid indeed, graphite is used as an electrical conductor in industry and as electrodes in electrochemical cells and batteries. Its... [Pg.725]

Measurement of electrical potential differences requires a complete electrical circuit, i.e., the electrochemical cell. An electrochemical galvanic cell consisting of all conducting phases, and among them at least one interface separating two immiscible electrolyte solutions is called for short a liquid galvanic cell. In contrast, the system composed of con-... [Pg.25]


See other pages where Electrochemical cells conduction is mentioned: [Pg.351]    [Pg.1926]    [Pg.330]    [Pg.509]    [Pg.295]    [Pg.878]    [Pg.56]    [Pg.226]    [Pg.547]    [Pg.499]    [Pg.500]    [Pg.513]    [Pg.516]    [Pg.125]    [Pg.53]    [Pg.440]    [Pg.444]    [Pg.965]    [Pg.17]    [Pg.28]    [Pg.61]    [Pg.430]    [Pg.430]    [Pg.457]    [Pg.97]    [Pg.120]    [Pg.520]    [Pg.734]   
See also in sourсe #XX -- [ Pg.499 ]




SEARCH



Conductance cell

Conductance electrochemical cell

Electrochemical cell

Electrochemical cells electrically conducting

© 2024 chempedia.info