Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Drinking water maximum containment

The drinking water maximum contaminant level (MCL) set by the USEPA for altrazine is 0.003 mg/L and its Reference Dose (RfD) is 3.5 ingAcg-d. How many liters of water containing atrazine at its MCL would a person have to drink each day to e.xceed the RfD for this triazine herbicide ... [Pg.343]

Is vinyl chloride a hazard to the general public PVC products may contain traces of vinyl chloride, but it is volatile and so amounts would very extremely small. In any case, the maximum amount allowed in a product is controlled. The atmosphere inside cars and drinking water may contain some vinyl chloride if it leaches from plastic components or from... [Pg.170]

There is uncertainty as to what levels of MTBE in drinking water cause a risk to public health.9 U.S. EPA has issued an advisory suggesting that drinking water should not contain MTBE in concentrations >20-40 pg/L, based on taste and odor concerns, but has not issued a federal maximum contaminant level (MCL) for MTBE, which will be based on the ongoing U.S. EPA studies.1... [Pg.990]

For maximum protection of human health from the potential carcinogenic effects of exposure to arsenic through drinking water or contaminated aquatic organisms, the ambient water concentration should be zero, based on the nonthreshold assumption for arsenic. But a zero level may not be attainable. Accordingly, the levels established are those that are estimated to increase cancer risk over a lifetime to only one additional case per 100,000 population. These values are estimated at 0.022 pg As/L for drinking water and 0.175 pg As/L for water containing edible aquatic resources (USEPA 1980 Table 28.7). [Pg.1529]

A concern for alkaline as well as solid polymer electrolysers should be the sensitivity of the electrolysers to contaminants in the feed water. The minimum required water quality of an industrial solid polymer electrolyzer is ASTM type II water [48], which contains at maximum 5 pg L 1 of sodium and chlorine, and 3 pg L 1 Si02 [52], It should have a maximum conductivity of 0.25 pS cm 1. Clean drinking water meeting Dutch standards contains around 60 mg L 1 of... [Pg.317]

E m Mi i ti A concentration of 1 ppm for a substance means that each kilogram of solution contains 1 mg of the solute. For dilute aqueous solutions near room temperature, where 1 kg has a volume of 1 L, 1 ppm also means that each liter of solution contains 1 mg of solute. In the same way, a concentration of 1 ppb means that each liter of an aqueous solution contains 0.001 mg of solute. Values in ppm and ppb are frequently used for expressing the concentrations of trace amounts of impurities in air or water. Thus, you might express the maximum allowable concentration of lead in drinking water as 50 ppb, or about 1 g per 20,000 L. [Pg.436]

Safe Drinking Water Act. (1974, 1986, 1996). Specifically applied to water supplied for humans consumption, this act requires the EPA to set maximum levels for contaminants in water delivered to users of public water systems. Two criteria are established for a particular contaminant the maximum containment level goal (MCGL) and the maximum contaminant level (MCL). The former, the MCLG, is the level at which no... [Pg.412]

Research using gamma-ray irradiation at Seibersdorf has reported pseudo-first-order decomposition of TCE and PCE [17,18]. Flowever, a significant departure from pseudo-first-order kinetics was noted with the e-beam system. This may be due to dose rate effects (1890 Gy s 1 maximum vs. 1.5 Gy s 1 for 60Co), or due to nonuniform dose distribution, or a combination of both [52]. Fig. 6 shows the departure from first-order behavior seen when the e-beam system is used as the source for the irradiation of drinking water containing TCE. [Pg.339]

The 1993 Environmental Protection Agency (EPA) regulation contains standards for 84 chemicals and minerals in drinking water. According to the EPA one of the most prevalent of the listed contaminants is naturally occuring antimony. The maximum contaminant level for antimony and nickel has been set at 0.006 mg/L and 0.1 mg/L respectively. [Pg.7]


See other pages where Drinking water maximum containment is mentioned: [Pg.194]    [Pg.107]    [Pg.30]    [Pg.167]    [Pg.77]    [Pg.77]    [Pg.196]    [Pg.393]    [Pg.45]    [Pg.218]    [Pg.14]    [Pg.415]    [Pg.200]    [Pg.573]    [Pg.367]    [Pg.211]    [Pg.211]    [Pg.60]    [Pg.63]    [Pg.106]    [Pg.80]    [Pg.195]    [Pg.200]    [Pg.573]    [Pg.1578]    [Pg.77]    [Pg.387]    [Pg.393]    [Pg.303]    [Pg.58]    [Pg.238]    [Pg.17]    [Pg.568]    [Pg.3]    [Pg.58]    [Pg.350]    [Pg.291]   


SEARCH



Drinking water

Drinking water containing

Drinking water maximum containment levels

Drinking water, maximum

Water Containment

Water containers

© 2024 chempedia.info