Many misconceptions exist about cascade control loops and their purpose. For example, many engineers specify a level-flow cascade for every level control situation. However, if the level controller is tightly tuned, the out-flow bounces around as does the level, regardless of whether the level controller output goes direcdy to a valve or to the setpoint of a flow controller. The secondary controller does not, in itself, smooth the outflow. In fact, the flow controller may actually cause control difficulties because it adds another time constant to the primary control loop, makes the proper functioning of the primary control loop dependent on two process variables rather than one, and requites two properly tuned controllers rather than one to function properly. However, as pointed out previously, the flow controller compensates for the effect of the upstream and downstream pressure variations and, in that respect, improves the performance of the primary control loop. Therefore, such a level-flow cascade may often be justified, but not for the smoothing of out-flow. [Pg.70]

When the flow is choked, G = G is independent of external downstream pressure. Reducing the downstream pressure will not increase the flow The mass flow rate under choking conditions is directly proportional to the upstream pressure. [Pg.649]

Cavitation and Flashing From the discussion on pressure recoveiy it was seen that the pressure at the vena contracta can be much lower than the downstream pressure. If the pressure on a hquid falls below its vapor pressure (p,J, the liquid will vaporize. Due to the effect of surface tension, this vapor phase will first appear as bubbles. These bubbles are carried downstream with the flow, where they collapse if the pressure recovers to a value above p,. This pressure-driven process of vapor-bubble formation and collapse is known as cavitation. [Pg.789]

Flow Nozzles A simple form of flow nozzle is shown in Fig. 10-17. It consists essentially of a short cylinder with a flared approach section. The approach cross section is preferably elliptical in shape but may be conical. Recommended contours for long-radius flow nozzles are given in ASME PTC, op. cit., p. 13. In general, the length of the straight portion of the throat is about one-h f throat diameter, the upstream pressure tap is located about one pipe diameter from the nozzle inlet face, and the downstream pressure tap about one-half pipe diameter from the inlet face. For subsonic flow, the pressures at points 2 and 3 will be practically identical. If a conical inlet is preferred, the inlet and throat geometry specified for a Herschel-type venturi meter can be used, omitting the expansion section. [Pg.892]

For compressible fluids one must be careful that when sonic or choking velocity is reached, further decreases in downstream pressure do not produce additional flow. This occurs at an upstream to downstream absolute pressure ratio of about 2 1. Critical flow due to sonic velocity has practically no application to liquids. The speed of sound in liquids is very liigh. See Sonic Velocity later in this chapter. [Pg.3]

AP = Line pressure drop, psi P], P2 = Upstream and downstream pressures in psi ABS S = Specific gravity of vapor relative to water = 0.00150 MP,/T d = Pipe diameter in inches Ui = Upstream velocity, ft/sec f = Friction factor (assume. 005 for approximate work)... [Pg.9]

Pipecalc 2.0, Gulf Publishing Company, Houston, Texas. Note Pipecalc 2.0 will calculate the compressibility factor, minimum pipe ID, upstream pressure, downstream pressure, and flow rate for Panhandle A, Panhandle B, Weymouth, AGA, and Colebrook-White equations. The flow rates calculated in the above sample calculations will differ slightly from those calculated with Pipecalc 2.0 since the viscosity used in the examples was extracted from Figure 5, p. 147. Pipecalc uses the Dranchuk et al. method for calculating gas compressibility. [Pg.10]

Lapple s method is useful when the upstream pressure of a header is known and the downstream pressure has to be calculated. However, it is often required to develop the pressure profile of the flare headers as a function of the distance from the stack. For this reason, it is more convenient to calculate the pressure drop backward, starting from the flare stack exit where the pressure is atmospheric. Figure 20 provides another plot which enables the pressure loss calculation when the downstream pressure is known. [Pg.327]

Once the diameter is known, the Reynolds number. Re can be computed and the friction factor f obtained from Figure 21. Assuming a straight length of pipe for L = 5(X) ft, N (line resistance factor) can be calculated. Next Gj, is calculated based on the downstream pressure and G/G j evaluated. From Figure 20 the ratio Pj/Pfl can be obtained. Since Pj is known, Pq can then be calculated. The pressure at the inlet of the knock-out drum is given by Pq -I- 0.5 psi. Table 6 provides typical values of resistance coefficients for various pipe fittings. [Pg.329]

Pa = absolute downstream pressure (N/m ) y = gas specific heat ratio (Cp/Cv, dimensionless)... [Pg.236]

With extreme v elocities of liquid in a pipe, the downstream pressure may fall to the v apor pressure of the liq-... [Pg.71]

In general, the sonic or critical velocity is attained for an outlet or downstream pressure equal to or less than one half the upstream or inlet absolute pressure condition of a system. The discharge through an orifice or nozzle is usually a limiting condition for the flow through the end of a pipe. The usual pressure drop equations do not hold at the sonic velocity, as in an orifice. Conditions or systems exhausting to atmosphere (or vacuum) from medium to high pressures should be examined for critical flow, otherwise the calculated pressure drop may be in error. [Pg.108]

These conditions are similar to flow through orifices, nozzles, and venturi tubes. Flow through nozzles and venturi devices is limited by the critical pressure ratio, r,. = downstream pressure/upstream pressure at sonic conditions (see Figure 2-38C). [Pg.115]

Safety Valve Required to Prelect Reducing Station Discharge Pressure in Cose of Valve Failure. SV-I is Set at Slightly Above Downstream Pressure of Reducing Station,and Protects All Equipment Operating at this Pressure on Steam Header. [Pg.429]

Thus, if the dowmstream or backpressure on tlie valve is less than 53%-60% (should be calculated) of the values of P, note above, critical (sonic) flow wll usually exist. If the downstream pressure is over approximately 50% of the relief pressure, P, the actual critical pressure should be calculated to determine the proper condition. Calculation of critical pressure [29] ... [Pg.438]

When/if the downstream pressure exceeds the critical flow pressure, then sub-critical pressure will occur and the equations for sub-critical flow should be used. [Pg.440]

When the downstream pressure is less than (or below) the critical or choked pressure, the velocity and fluid flow rate at a restriction or throat wall not/cannot be increased by lowering the downstream pressure further, and the fluid velocity at the restriction or throat is the velocity of sound at the conditions [29]. [Pg.440]

For rupture disk sizing the downstream pressure is assumed to reach the critical flow pressure although the dowm stream pressure initially may be much low er. Under these conditions the flow through the orifice that the disk produces on rupture is considered to be at critical flow. The assumptions of critical pressure do not apply... [Pg.455]

To select the proper sizing equation, determine whether the flowing conditions are sonic or subsonic from the equations. When the absolute pressure downstream or exit of the throat is less than or equal to the critical flow pressure, P., then the flow is critical and the designated equations apply [33a]. WTien the downstream pressure exceeds the critical flow pressure, P,., then sub-... [Pg.459]

Equations 2-65 and 2-66 apply only as long as the fluid velocity at the throat of the choke is subsonic. Sonic velocity is the speed of a pressure wave in a fluid. Once sonic velocity is achieved, the effects of the downstream pressure can no longer be transmitted to the upstream side of the choke. [Pg.181]

A 0.6 gravity hydrocarbon gas flows from a 2-in. ID pipe through a I-in. ID orifice plate. The upstream temperature and pressure are 75°F and 800 psia, respectively. The downstream pressure is 200 psia. Does heating need to be applied to assure that frost does not clog the orifice What will be the flow rate ... [Pg.183]


See other pages where Downstream pressure is mentioned: [Pg.226]    [Pg.189]    [Pg.61]    [Pg.94]    [Pg.95]    [Pg.58]    [Pg.70]    [Pg.648]    [Pg.650]    [Pg.778]    [Pg.778]    [Pg.793]    [Pg.795]    [Pg.795]    [Pg.893]    [Pg.894]    [Pg.894]    [Pg.895]    [Pg.1699]    [Pg.2049]    [Pg.2054]    [Pg.2288]    [Pg.2292]    [Pg.474]    [Pg.475]    [Pg.291]    [Pg.342]    [Pg.329]    [Pg.334]    [Pg.1160]   