Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Double-focusing sector

Table 6.29 Main characteristics of double-focusing sector mass spectrometers... Table 6.29 Main characteristics of double-focusing sector mass spectrometers...
Direct-fluid-injection (DFI)a Electron impact (El) Double-focusing sector (DFS)... [Pg.479]

With few exceptions, magnetic sector instruments are comparatively large devices capable of high resolution and accurate mass determination, and suited for a wide variety of ionization methods. Double-focusing sector instruments are the choice of MS laboratories with a large chemical diversity of samples. In recent years, there is a tendency to substitute these machines by TOE or by Fourier transform ion cyclotron resonance (FT-ICR) instruments. [Pg.131]

Combination of Magnetic and Electric Sector Fields - Double-focusing Sector Field Mass Spectrometer... [Pg.83]

Figure 3.5 Double-focusing sector field mass spectrometer with Nier-johnson geometry. (77. Kienitz (ed.), Massenspektrometrie (1968), Verlag Chemie, Weinheim. Reproduced by permission ofWiley-VCH)... Figure 3.5 Double-focusing sector field mass spectrometer with Nier-johnson geometry. (77. Kienitz (ed.), Massenspektrometrie (1968), Verlag Chemie, Weinheim. Reproduced by permission ofWiley-VCH)...
A special experimental arrangement of double-focusing sector field mass spectrometry - the... [Pg.85]

Figure 3.6 Schematicofa double-focusing sector field mass spectrograph with Mattauch-Herzog geometry with a linear imaging curve (double focusing for ions of all masses simultaneously) modified field combination with 70°. In the mass spectrograph, photographic ion detection or focal plane array detectors are used for quasi-simultaneous detection of separated ion beams. (H. Kienitz (ed.), Massen-spektrometrie (1968), Verlag Chemie, Weinheim. Reproduced by permission of Wiley-VCH)... Figure 3.6 Schematicofa double-focusing sector field mass spectrograph with Mattauch-Herzog geometry with a linear imaging curve (double focusing for ions of all masses simultaneously) modified field combination with 70°. In the mass spectrograph, photographic ion detection or focal plane array detectors are used for quasi-simultaneous detection of separated ion beams. (H. Kienitz (ed.), Massen-spektrometrie (1968), Verlag Chemie, Weinheim. Reproduced by permission of Wiley-VCH)...
Magnetic sector field equilibr Lorentz force and centrifugal force mv2 n-e-v-B= 2 - direction focusing (lens effect) - separation after m/z (prism effect) 1 500 5 000 TIMS, organic ms, double-focusing sector field ms, tandem ms... [Pg.98]

Figure 4.4 Schematic (a) and photograph of ion detector with extended dynamic range (b) in the double-focusing sector field mass spectrometer Element. (Reproduced by permission of Thermo Fisher Scientific, Bremen.)... Figure 4.4 Schematic (a) and photograph of ion detector with extended dynamic range (b) in the double-focusing sector field mass spectrometer Element. (Reproduced by permission of Thermo Fisher Scientific, Bremen.)...
Double-focusing sector field mass spectrometer... [Pg.119]

An overview of commercial ICP mass spectrometers from different companies (quadrupole based ICP-MS with and without collision/reaction cell, double-focusing sector field instrumentation with single and multiple ion collectors, time-of-flight (ToF), ICP-ion trap-MS and non-commercial ICP-Fourier transform ion cyclotron resonance (FTICR) mass spectrometers is given in Figure 5.2. By using ion traps and FTICR mass spectrometers in ICP-MS isobaric interferences of atomic ions... [Pg.120]

As an alternative to commercial quadrupole based ICP-MS measurements at low mass resolution ( / 300), in 1996 Yiang and Douglas15 proposed a quadrupole ICP-MS system which allows a maximum mass resolution of 9000. At a mass resolution of 5000 the sensitivity was comparable to that of a commercial double-focusing sector field ICP-MS operated at the same mass resolution. Due to the very high continuum instrumental background of about lOOOcps no commercial high resolution quadrupole instrumentation with an inductively coupled plasma source exists and the development of high resolution quadrupole based ICP-MS has ceased. [Pg.123]

Double-focusing Sector Field ICP Mass Spectrometers with Single Ion Collector (ICP-SFMS)... [Pg.131]


See other pages where Double-focusing sector is mentioned: [Pg.540]    [Pg.178]    [Pg.36]    [Pg.42]    [Pg.57]    [Pg.485]    [Pg.752]    [Pg.45]    [Pg.67]    [Pg.332]    [Pg.134]    [Pg.547]    [Pg.17]    [Pg.20]    [Pg.28]    [Pg.36]    [Pg.43]    [Pg.48]    [Pg.54]    [Pg.84]    [Pg.84]    [Pg.84]    [Pg.95]    [Pg.98]    [Pg.100]    [Pg.107]    [Pg.120]    [Pg.127]    [Pg.131]    [Pg.132]    [Pg.132]    [Pg.132]    [Pg.132]    [Pg.133]   
See also in sourсe #XX -- [ Pg.2 , Pg.401 , Pg.426 ]




SEARCH



Analyzer double-focusing sector field

Analyzers Double-Focusing Magnetic Sector Technology

Double focusing

Double focusing magnetic sector instrument

Double-Focusing Sector Instruments

Double-focusing magnetic sector

Double-focusing magnetic sector mass analyzer

Double-focusing sector field

Double-focusing sector field ICP mass spectrometry

Double-focusing sector field mass

Double-focusing sector field mass spectrometer

Double-focusing sector field mass spectrometer with Mattauch-Herzog geometry

Double-focusing sector field mass spectrometer with Nier-Johnson geometry

Double-focusing sector mass

Double-focusing sector mass spectrometer

Geometries of Double-Focusing Sector Instruments

Magnetic sector analyzer double-focusing

Magnetic sector mass spectrometers double-focusing

Mass spectrometer high-voltage, double-focusing, sector

Sector

Sectorization

Single double-focusing sector field mass

The Double-Focusing and Tri-Sector Mass Analysers

© 2024 chempedia.info